Operation and Monitoring
Sentinel Kinetic MVHR Operation & Monitoring
8
User Menu Screens
From the Normal Airflow screen, press the
button to access the rest of the User Menu screens.
Changing the value of a setting (if adjustable) is typically a 3-step procedure:
1.
Press
to select the setting (the setting will flash).
2.
Use the
or
buttons to adjust the value. To scroll quickly, press and hold the
or
buttons for
more than 2 seconds.
3.
Press
again to enter the new settings and move to the next screen.
To return to the Normal Airflow screen, press the
button repeatedly or press and hold the
button for 5
seconds. Alternatively, the Normal Airflow screen will be restored if no buttons are pressed for two minutes
(timeout). Settings are stored in a the memory and will be retained in the event of mains power supply failure.
Low Airflow / Normal Airflow / Boost Airflow Screen
When the start-up screens are finished, the Low or
Normal screen is displayed showing operating status
(Low Airflow X % or Normal Airflow X % or Boost
Airflow X %).
The Normal screen displays the rate of normal airflow
(supply air) through the unit.
If the installation has proportional sensors or an internal
humidity sensor fitted, an
α
symbol will be displayed
when they are boosting the airflow.
Normal Airflow
30 %
When the summer bypass is active, the normal screen
top line will alternate (for 3 seconds) with Summer
Bypass.
SUMMER BYPASS ON
30 %
An interval can be set, see the Installation and
Commissioning manual, at which the unit reminds the
user to check the filters. This will be 6, 12 or 18
months. The normal screen top line will include Check
Filter as a reminder to check and, if necessary, clean or
replace the filters.
When this has been done, press and hold the
and
buttons for 5 seconds to reset the automatic
message.
Check Filter
30 %