JPH/C2 1213A

Installation Details Continued

11) FOR BACK VENTING APPLICATIONS ONLY. IF NOT BACK VENTING, PROCEED DIRECTLY TO STEP 12. Note: Wall 

studs may interfere with back venting installations. Additional framing may be required. It is necessary to cut duct 

access hole(s) in the wall prior to installing the hood.

 

Using the applicable venting accessories and the connection diagrams (page 4) as a guide, install the duct(s) from the 

outside of the home to the wall over the exhaust outlet(s) on the hood. The end of the duct(s) should extend 1" past 

the wall.

12) Hang the hood on the mounting strip by aligning the channel at the top of the back of the hood over the wood mounting 

strip on the wall. While holding the hood in place, mark locations on the mounting strip through the two mounting 

holes in the channel at the top of the hood. Some mounting holes may be located behind the blower(s). Remove the 

hood and drill 3/32" pilot holes at the center of the marks in the wood strip to prevent splitting.

13) FOR BACK VENTING APPLICATIONS ONLY. IF YOU ARE NOT BACK VENTING, PROCEED DIRECTLY TO STEP 14.

 

Place the appropriate elbow(s) on the top of the hood. Elbow(s) should be placed with the non-crimped end(s) on the 

inside the collar(s) of the exhaust outlet(s). Use duct tape to seal joints. Insert the electrical wire from the service panel 

into the electrical wire clamp on each motor box. Tighten the wire clamp(s). While securing the slack in the wire, lift 

the hood up to the wall and hang the hood on the mounting strip, taking care to properly align the duct connection(s) 

between the elbow(s) on the hood and the duct(s) in the wall. Secure the hood to the mounting strip by installing the 

screws (previously removed from the strip in Step 10) into the pilot holes drilled in Step 12.

 

SKIP STEP 14. PROCEED DIRECTLY TO STEP 15.

14) If applicable, install the transition on the insides of the exhaust collars and seal with duct tape.

 

Insert the electrical wire from the service panel into the electrical wire clamp on each motor box. Tighten the wire 

clamp(s). Cut a piece of duct for each outlet of sufficient length to meet the duct(s) in the ceiling allowing room for 

the transition (if applicable). If a transition is used, cut the duct to reach the transition outlet plus 1”. This will allow 

the transition to engage 1” inside of the duct. See page 3 for transition heights. One end of the duct must be crimped 

to fit inside the duct in the ceiling. Insert the non-crimped end over the transition or into the exhaust collar(s) on the 

top of the hood and seal with duct tape. While securing the slack in the wire, lift the hood up to the wall and hang the 

hood on the mounting strip, taking care to properly align the duct connection(s) between the hood and the duct in the 

ceiling. Secure the hood to the mounting strip by installing the screws (previously removed from the strip in Step 10) 

into the pilot holes drilled in Step 12.

15) From inside the hood, using UL listed wire nuts, attach the “neutral” wire(s) to the white lead(s), the “hot” wire(s) to 

the black lead(s), and the ground wire(s) to the green lead(s) inside the motor box(es).

Warning:  Do not operate hood without  proper ground connection.

16) Plug the motor(s) into the hood and reinstall the blower motor(s) using the three retaining screws that were previously 

removed in Step 6.

17) Replace the blower housing(s) and the blower shield(s). Make sure that the damper(s) open and close smoothly.

18) Refer to the Owner Maintenance Guide Operating Instructions for proper hood operation. Test all blower and light 

functions to ensure they are operating properly.

Summary of Contents for JPH DESIGNER SERIES

Page 1: ...lling into wall or ceiling do not damage electrical wiring and other hidden utilities C Ducted fans must always be vented to the outdoors D Sufficient air is needed for proper combustion and exhaustin...

Page 2: ...00 B200 10 round or equivalent 79 sq in VP562 Optional Two Duals Two B200s 12 round or equivalent 113 sq in VP563 Optional Ducting Requirements NEVER reduce the duct size When combining ducts together...

Page 3: ...he duct s should extend 1 below the ceiling Use duct tape to seal all joints A complete listing of available Vent A Hood ducting materials is provided on the back page of this instruction sheet Transi...

Page 4: ...6 1 11 11 5 5 Wall Side 5 1 Electrical 2 8 Outlet Vent Holes 8 Outlet Centerline of Hood Installation Details Continued Connection Diagram 36 48 Widths 300 CFM B100 Single Blower Top View 600 CFM B200...

Page 5: ...l Volts Amps Hz RPM CFM SP 0 0 Equivalent CFM CFM SP 0 1 CFM SP 0 2 CFM SP 0 3 Minimum Round Duct Size Sones B100 Single 115 1 5 60 1550 300 450 273 245 225 6 28 in 2 5 4 B200 Dual 115 2 9 60 1550 600...

Page 6: ...previously removed from the strip in Step 10 into the pilot holes drilled in Step 12 SKIP STEP 14 PROCEED DIRECTLY TO STEP 15 14 If applicable install the transition on the insides of the exhaust col...

Page 7: ...23 VP563 30 3 x 10 TO 7 TRANSITION MODEL DIM VP521 3 x 10 to 7 7 7 3 10 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 6 VP539 VP540 VP541 6 Round 7 Round 8 Round 16 16 LOW PROFILE ROOF JACK MAXI...

Reviews: