48
Advanced Setup Table
cont. next page
Df = Factory Default Setting
Step# Description
Pg# Range
Df
1
Prog Mode
17
Non, 7 Day
7
2
Available Modes
17
Heat/Cool/Auto/Off, Heat/Cool/Off, Heat/Cool/
Heat/Off, Cool/Off
Auto/Off
3
Backlight
18
On, Off
Off
4
Backlight Level
18
Off through 7 levels of brightness Level 5
5
Night Dimmer
18
On/Off
Off
6
Night Dimmer Brightness
18
Off through 7 levels of brightness 2 (20%)
7
Night Dimmer Start Time
18
12A-12A
8:00P
8
Night Dimmer Stop Time
18
12A-12A
6:00A
9
Current Service Filter Runtime Hours
18
0-1999 Hours
0
10
Current Service Filter Calendar Days
18
0-720 Days
0
11
Current Heat Runtime Hours
19
0-1999 Hours
0
12
Current Aux Heat Runtime Hours
19
0-1999 Hours
0
13
Current Cool Runtime Hours
19
0-1999 Hours
0
14
Current Override Hours
19
0-1999 Hours
0
15
Current UV Lamp Calendar Days
19
0-720 Days
0
16
Current Humidifier Calendar Days
19
0-720 Days
0
17
Set Service Filter Runtime Hours
20
0-1950 hours
0
18
Set Service Filter Calendar Days
20
0-720 Days
0
19
Set UV Lamp Calendar Days
20
0-720 Days
0
20
Set Humidifier Calendar Days
20
0-720 Days
0
21
Language
20
English, Espanol, Francais
English
22
Setpoint Limits
21
0 - 3
0
23
Max Heat Setpoint
21
35 - 99 Degrees
74
24
Min Cool Setpoint
21
35 - 99 Degrees
70
25
Cycles Per Hour
22
No Limit, 2, 3, 4, 5, 6
6
26
Compressor Minimum Off Minutes
22
0,3,5
5
27
Min. Heat/Cool Setpoint Difference
22
0 - 6 Degrees
2
28
Number of Heat Stages
22
0 - 3
2
29
Number of Cool Stages
22
0 - 2
1
30
Number Of Compressor Stages
22
1, 2
1
31
Number of Auxiliary Stages
22
0, 1, 2
0
32
1st Stage Deadband
23
1 - 6 Degrees
2
33
2nd Stage Deadband
23
0 - 10 Degrees
2
34
3rd Stage Deadband
23
0 - 10 Degrees
2
35
4th Stage Deadband
23
0 - 10 Degrees
2
36
Minutes Between 1st and 2nd Stage
23
0 - 60 Minutes
2
37
Minutes Between 2nd and 3rd Stage
23
0 - 60 Minutes
2
38
Minutes Between 3rd and 4th Stage
23
0 - 60 Minutes
2
39
2nd StageTurnoff Point
24
Deadband, Setpoint
Deadband