background image

Typical 

Thermostat

RS

RS+5

RS-GND

Blue

Orange

Brown

Outdoor Sensor

DOWN

RS

RS-GND

RS+5

OUTDOOR INSTALLATION      Perform the following procedures to install the sensor: 
   1.  Cut a 1 x 2½-in. mounting hole in the wall.  
   2.  Attach the mounting plate to the wall.  If the Outdoor Sensor is mounted on a 
        rough surface, it is recommended that silicon rubber sealant be used around the 
        entire edge of the mounting plate.  

If mounting on an electrical junction box, be 

        sure the seal between the junction box and sensor mounting plate is tight.

INDOOR INSTALLATION      Perform the following procedures to install the sensor:
   1.  Place the Outdoor Sensor wall plate on the wall.  Mark the
        mounting screw holes on the wall through the holes in 
        the wall plate.
   2.  Drill two 3/16-in. mounting holes in the wall in the location 
        marked in Step 1.  
   3.  Mount the Outdoor Sensor wall plate to the wall with the 
        screws provided. 

Sensor Installation

Sensor Wiring

DOWN

RS

RS-GND

RS+5

Screw 
hole

Screw 
hole

The  connection  between  the  Outdoor  Sensor  and  the 
thermostat must be wired per the connection diagram. 
Only  three  conductors  are  used,  therefore  the  extra 
conductors should be cut from each end of the cable to 
prevent shorting.  Follow the color coding as shown.

WARNING

Turn off power to the thermostat before wiring.  Death 
or injury from electric shock could result.

©Venstar Inc. 08/07          

P/N 88-623     Rev. 1

DIGITAL OUTDOOR

TEMPERATURE SENSOR

ACC0400

MODEL