background image

INST
ALLA
TION MANUAL

SERVICE P

AR

TS

23

K

EY

 

NO

.

P

ART

 

NO

.

D

ESCRIPTION

Q

UANTITY

30"

S

TAINLESS

30"

W

HITE

1

S97020030

R

ECIRCULATION

 

COVER

 

PLATE

, W

HITE

 (

INCLUDING

 

SCREWS

)

1

S97020031

R

ECIRCULATION

 

COVER

 

PLATE

, S

TAINLESS

 

STEEL

 (

INCLUDING

 

SCREWS

)

1

2

S97020534

3¼” 

X

 10” D

AMPER

 

ASSEMBLY

 (

INCLUDING

 

SCREWS

)

1

1

3

S97020408

B

LOWER

 

MOTOR

 (

INCLUDING

 4 

SCREWS

 

AND

 1 

CAPACITOR

)

1

1

4

S97020407

F

ANPELLER

 (

INCLUDING

 

ITEM

 5)

1

1

5

SR99420635

C

LIP

 

FOR

 

FANPELLER

1

1

6

S99010430-002 G

REASE

 F

ILTER

 - O

PEN

 M

ESH

 -T

YPE

 C1 (

SET

 

OF

 2)

1

1

7

S97020422

E

LONGATED

 

ROCKER

 

SWITCH

, G

REY

 (

INCLUDING

 

SCREWS

)

1

S97020421

E

LONGATED

 

ROCKER

 

SWITCH

, W

HITE

 (

INCLUDING

 

SCREWS

)

1

8

SV05921

S

HIELDED

 

HALOGEN

 

BULB

 50 W, GU10

2

2

*

S97020448

W

IRE

 

HARNESS

1

1

*

S98011637

W

IRING

 

COVER

1

1

*

S97020292

P

ARTS

 

BAG

 

INCLUDING

: 4 M

ETAL

 

SCREWS

 

NO

. 8-18 

X

 1/2”, 

6 R

OUND

 

HEAD

 

NO

. 8 

X

 5/8” 

WOOD

 

SCREWS

NO

. 8 

X

 1/2” C

OUNTERSUNK

 

WOOD

 

SCREWS

,1 S

UCTION

 

CUP

 

TOOL

1

1

*

S97020466

N

ON

-

DUCTED

 F

ILTER

 - T

YPE

 X

C

 (

SET

 

OF

 2) 

(

NON

-

DUCTED

 

INSTALLATION

 

ONLY

)

1

1

*

S99527587

N

ON

-

DUCTED

 

FILTER

 

CLIP

 

KIT

 (

INCLUDES

 4 

CLIPS

)

1

1

*

S97020470

E

ASY

 

INSTALL

 

KIT

 (

INCLUDING

 

HARDWARE

)

1

1

VBLSH1 SERIES

* I

TEM

 

NOT

 

SHOWN

.

R

EPLACEMENT

 P

ARTS

 

AND

 R

EPAIRS

In order to ensure your unit remains in good working condition, you must use Venmar Ventilation ULC genuine replacement parts only. 
The Venmar Ventilation ULC genuine replacement parts are specially designed for each unit and are manufactured to comply with 
all the applicable certification standards and maintain a high standard of safety. Any third party replacement part used may cause 
serious damage and drastically reduce the performance level of your unit, which will result in premature failing. Venmar Ventilation ULC 
recommends to contact a certified service depot for all replacement parts and repairs.

Summary of Contents for VBLDF1

Page 1: ...WWW VENMAR CA Serial number 99045653 002D RANGE HOOD Series VBLDF1 and VBLSH1 INSTALLATION USE AND CARE MANUAL...

Page 2: ...ommended Tools and Accessories for Installation 7 Install Ductwork Ducted Installations Only 7 Contents 8 Prepare the Hood 9 11 Prepare the Hood Location 12 EZ1 One Person Installation 12 14 Install t...

Page 3: ...fficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guidelines a...

Page 4: ...d you know how to operate it B The fire is small and contained in the area where it started C The fire department has been called D You can fight the fire with your back to an exit Based on Kitchen Fi...

Page 5: ...eep is heard and LED indicators light up to show the corresponding speed chosen lower LED for LOW speed lower and center LEDs for MEDIUM speed and all LEDs for HIGH speed When blower is on no matter t...

Page 6: ...equently Use a clean cloth soaked with warm detergent solution STAINLESS STEEL CLEANING Do Regularly wash with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent Always c...

Page 7: ...N 24 MAX ABOVE COOKING SURFACE CABINET 3 X 10 DUCT FOR HORIZONTAL DISCHARGE WALL CAP ROOF CAP 3 X 10 OR 7 ROUND DUCT FOR VERTICAL DISCHARGE HOUSE WIRING TOP OR BACK OF HOOD HOOD NOTE Distances over 24...

Page 8: ...binet Pour une installation sous une armoire fond en retrait utiliser les lignes pour mesurer l paisseur du d calage caus par le mur de l armoire et plier le gabarit en cons quence To be translated in...

Page 9: ...rs out 3 Remove the EZ1 brackets from inside the hood by cutting off the tie wrap Remove both screws holding damper assembly to hood Remove parts bag captured behind the damper assembly Remove damper...

Page 10: ...ve Electrical Power Cable Knockout from top vertical wiring or back horizontal wiring of hood Install an appropriate strain relief 1 2 diameter not included NON DUCTED INSTALLATION ONLY 7 Remove 3 scr...

Page 11: ...plate can be installed up to 1 2 on either side of the hood center 7 ROUND KNOCKOUT PLATE ALSO REMOVE VERTICAL KNOCKOUT PLATE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10 HORIZONTAL KNOCKOUT PLATE FIGURE 1 A...

Page 12: ...iser les lignes pour mesurer l paisseur du d calage caus par le mur de l armoire et plier le gabarit en cons quence To be translated in Spanish P C CABINET FRONT C L A B VERTICAL EXHAUST A S A A V RTI...

Page 13: ...rews Repeat for the other side frame 7 Install the proper installation brackets according to the type of cabinet framed or frameless See below 4 Drill a 1 8 dia pilot hole for house wiring at A locati...

Page 14: ...n the outer edge of the bracket as shown Slide the bracket towards the center of cabinet and align the outside edge of the bracket with the marked line keeping the rear end edge leaning on the wall Us...

Page 15: ...ing the hood run the house power cable into the hood through the strain relief previously installed in step 6 on page 10 4 Unhook the rear holes from the brackets and hang the hood using its 2 recesse...

Page 16: ...rts bag Insert 2 screws per side in the slots as shown in insets on illustration below 8 For frameless cabinet secure the hood to the cabinet using 4 no 8 x 5 8 round head wood screws included in part...

Page 17: ...CAL DUCT ACCESS HOLE 1015 16 5 5 CENTER LINE HOOD MOUNTING SCREWS 4 ELECTRICAL ACCESS HOLE IN CABINET BOTTOM WOOD SHIMS RECESSED BOTTOM CABINETS ONLY CABINET FRONT 3 4 1 1 7 16 12 47 16 CABINET BOTTOM...

Page 18: ...4 mounting screws previously installed Slide hood back towards wall until mounting screw heads are engaged in narrow end of keyhole slots in top of hood Tighten screws securely Attach power cable to...

Page 19: ...andards Before connecting wires switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally CAUTION Ensure both tabs on inner top of hoo...

Page 20: ...mps during or soon after operation Burns may occur In order to prevent the risk of personal injury only install shielded halogen lamps Also never install a cool beam a dichroic lamp a lamp not suitabl...

Page 21: ...High W 120 V AC Line Neutral Ground G Y W BK O R FAN MOTOR BN BN W R BK LED LED W COLOR CODE BK BL BN BN W BLACK BLUE BROWN BROWN WHITE G Y O R W GREEN YELLOW ORANGE RED WHITE 1 2 3 4 5 6 VBLDF1 SERIE...

Page 22: ...ER PLATE WHITE INCLUDING SCREWS 1 S97020031 RECIRCULATION COVER PLATE STAINLESS STEEL INCL SCREWS 1 2 S97020534 3 X 10 DAMPER ASSEMBLY INCLUDING SCREWS 1 1 1 3 S97020409 BLOWER MOTOR INCLUDING 4 SCREW...

Page 23: ...18 X 1 2 6 ROUND HEAD NO 8 X 5 8 WOOD SCREWS 6 NO 8 X 1 2 COUNTERSUNK WOOD SCREWS 1 SUCTION CUP TOOL 1 1 S97020466 NON DUCTED FILTER TYPE XC SET OF 2 NON DUCTED INSTALLATION ONLY 1 1 S99527587 NON DU...

Page 24: ...t or replacement parts to you at no charge You are responsible for all costs for removal reinstallation and shipping insurance or other freight charges incurred in the shipment of the Product or part...

Reviews: