background image

5

3. PREPARE INSTALLATION

    WARNING

!

Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. This 
range hood must be properly grounded. Turn off electrical power at service entrance before wiring. 

NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the retailer.

Make sure that the following items are included:

- Hood
-  Decorative flue assembly (lower and upper flues)
-  Hood mounting bracket
-  Lower flue mounting bracket
-  Upper flue mounting bracket
-  2 Aluminum grease filters
-  6" Round adapter/damper
-  Curved glass plate
- Installation 

instructions

-  Parts bag:  8 no. 8 x 7/16" mounting screws, 

7 no. 8 x 1½" mounting screws, 
9 drywall anchors, 2 washers, 
2 no. 8 x 1¼" mounting screws, 
4 aesthetic washers, 
4 M4 x 0.7" mechanical flat head screws

 

NOTE: If need be, discard extra screws.

Parts sold separately:

-  Ducts, elbows, wall and roof caps.
-  Optional flue extension for 10-ft. ceilings model no. 09877.

NOTE: During installation, protect countertop and/or cooktop.

HR0031A

D

ECORATIVE

FLUE

L

OWER

 

FLUE

MOUNTING

 

BRACKET

H

OOD

MOUNTING

 

BRACKET

U

PPER

 

FLUE

MOUNTING

 

BRACKET

6” R

OUND

 

ADAPTER

/

DAMPER

4. WIRING INSTALLATION

GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an 
escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must 
be plugged into an outlet that is properly installed and grounded.
Set the electrical power supply within the space covered by the decorative flue.

Position the outlet offset so that the power cord will not interfere with the round duct. 
Place the outlet at a maximum distance of 33

7

/

16

" from where the cord exits from 

the hood (see illustration at right). Make sure this does not interfere with a mounting 
bracket fastening area or with the decorative flue (where the flue touches the wall).

    WARNING

!

Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding instructions 
are not completely understood, or if doubt exists as to whether the appliance is properly grounded. Do not use an 
extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance.

HE0159

33

7

16

MAX

.

Summary of Contents for ISPIRA IC700 Series

Page 1: ...VE THIS MANUAL WITH HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGES 8 AND 9 READ AND SAVE THESE INSTRUCTIONS Venmar Ventilation ULC 550 Lemire Blvd Drummondville QC J2C 7W9 1 800 567 3855 REGIST...

Page 2: ...Suzette Cherries Jubilee Peppercorn Beef Flamb c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan filters or in exhaust ducts d Use proper pan size Always use cookwa...

Page 3: ...rized service provider The unit removal and reinstallation works are under the customer responsibility and Venmar Ventilation ULC cannot be charged for them The duration of any implied warranty is lim...

Page 4: ...HOOD DECORATIVE FLUE HH0095A 26 MINIMUM ABOVE COOKING SURFACE 30 FOR GAS RANGE 2 MEASURE INSTALLATION The minimum hood distance above cooktop MUST NOT BE less than 26 A maximum of 30 above cooktop is...

Page 5: ...UNTING BRACKET HOOD MOUNTING BRACKET UPPER FLUE MOUNTING BRACKET 6 ROUND ADAPTER DAMPER 4 WIRING INSTALLATION GROUNDING INSTRUCTIONS This appliance must be grounded In the event of an electrical short...

Page 6: ...ake sure that the slots of the upper flue bracket point down Use the upper flue mounting bracket as a template to mark the position of its screws Drill both screw holes using a 5 16 drill bit Insert t...

Page 7: ...ible when space is sufficient Install the lower flue bracket to its flue using 2 no 8 x 7 16 mounting screws ensure that the slots point up Fig 3 6 Carefully place both flues into the recessed area of...

Page 8: ...W maximum G 4 Base halogen bulb 3 Replace the light bulb cover by pushing the rim upward and rotating the light bulb cover clockwise WARNING In order to prevent the risk of personal injury the haloge...

Page 9: ...on at the last selected speed and blower symbol will be activated To change the blower speed press the blower push button 3 until the desired speed is obtained Press the ON OFF push button 4 to turn t...

Page 10: ...so recommends to contact a Venmar certified service depot for all replacement parts and repairs KEY NO PART NO DESCRIPTION QUANTITY 1 07250 DECORATIVE UPPER AND LOWER FLUES 1 2 07243 MOTOR AND BLOWER...

Reviews: