Standard Installation (without EZ1 brackets)

1 ] 

Use the proper diagram below for placement of ductwork and electrical cutout in cabinet 
or wall. For a non-ducted installation, DO NOT cut a duct access hole, only cut the hole for 
electrical wiring.

2 ]  

Install part-way four (4) ROUND HEAD no. 8 x 5/8” mounting screws into shims/cabinet, 
according to the proper diagram above. (Mounting screws are included in parts bag, but wood 
shims and shim mounting screws are not included).

VERTICAL DUCT

ACCESS HOLE

10

15

/

16

"

5¼"

5¼"

CENTER

LINE

HOOD MOUNTING SCREWS (4)

ELECTRICAL

ACCESS HOLE

(

IN

 

CABINET

 

BOTTOM

)

WOOD SHIMS

(

RECESSED

-

BOTTOM

CABINETS

 

ONLY

)

CABINET FRONT

3/4"

1

Ǫ

"

1½"

7³/

16

"

12

Ǭ

"

4

7

/

16

"

CABINET

BOTTOM

12

Ǭ

"

3¼" 

X

 10"

VERTICAL DUCTING

CABINET

BOTTOM

CABINET FRONT

HORIZONTAL DUCT

ACCESS HOLE

HOOD

MOUNTING

SCREWS (4)

ELECTRICAL

ACCESS HOLE

(

IN

 

WALL

)

3

Ǭ

"

CENTER

LINE

WOOD SHIMS

(

RECESSED

-

BOTTOM

CABINETS

 

ONLY

)

13/16"

3/16"

5¼"

5¼"

12

Ǭ

"

12

Ǭ

"

7³/

16

"

3¼" 

X

 10"

HORIZONTAL DUCTING

ELECTRICAL

ACCESS HOLE

(

IN

 

CABINET

 

BOTTOM

)

HOOD MOUNTING SCREWS (4)

4¹¹/

16

"

8" DIA.

HOLE

7-IN. ROUND

DUCT

ACCESS

HOLE

7-IN. ROUND

DUCT

ACCESS

HOLE

WOOD SHIMS

(

RECESSED

-

BOTTOM

CABINETS

 

ONLY

)

Ǭ

"

Ǭ

10

15

/

16

"

1½"

Ǫ

7³/

16

"

7-IN. ROUND

VERTICAL DUCTING

Summary of Contents for Chef VCQDD1 Series

Page 1: ...WWW VENMAR CA Serial number 99045657 004D WWW VENMAR CA RANGE HOOD Series VCQDD1 and VCQSEN1 INSTALLATION USE AND CARE MANUAL...

Page 2: ...d Location 12 EZ1 Person Installation 12 14 Install the Hood EZ1 Bracket 15 16 Standard Installation 17 Install the Hood Standard Installation 18 Connect the Wiring 19 Install the Filters 19 Wiring Di...

Page 3: ...fficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guidelines a...

Page 4: ...nd you know how to operate it B The fire is small and contained in the area where it started C The fire department has been called D You can fight the fire with your back to an exit Based on Kitchen F...

Page 5: ...r will be set on LOW speed NOTE When LOW speed is activated from OFF the blower starts on MEDIUM speed for a very short lapse of time and then resume to LOW speed To change the blower speed press on t...

Page 6: ...LADE The fan blade should be cleaned frequently Use a clean cloth soaked with warm detergent solution STAINLESS STEEL CLEANING Do Regularly wash with clean cloth or rag soaked with warm water and mild...

Page 7: ...twork Ducted Installations Only SOFFIT 18 MIN 24 MAX ABOVE COOKING SURFACE CABINET 3 X 10 DUCT FOR HORIZONTAL DISCHARGE WALL CAP ROOF CAP 3 X 10 OR 7 ROUND DUCT FOR VERTICAL DISCHARGE HOUSE WIRING TOP...

Page 8: ...scale when installing to framed cabinet Pour une installation sous une armoire fond en retrait utiliser les lignes pour mesurer l paisseur du d calage caus par le mur de l armoire et plier le gabarit...

Page 9: ...er out 3 Remove the EZ1 brackets from inside the hood by cutting off the tie wrap Remove both screws holding damper assembly to hood Remove parts bag captured behind the damper assembly Remove damper...

Page 10: ...hood Install an appropriate strain relief 1 2 diameter not included NON DUCTED INSTALLATION ONLY 7 Remove 3 screws retaining the recirculation cover plate shaded part in illustration below to the hood...

Page 11: ...on either side of the hood center 7 ROUND KNOCKOUT PLATE ALSO REMOVE VERTICAL KNOCKOUT PLATE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10 HORIZONTAL KNOCKOUT PLATE FIGURE 1 A 7 ROUND DUCT PLATE SCREWS FIGUR...

Page 12: ...RTICAL EXHAUST A S A A V RTICAL EX 3 x 10 3 x 14 RECTANGULAR DUCTING 7 ROUND DUCTING OR Use this template for marking do not attempt to cut out the ducting hole through it NOTE These cutouts are clear...

Page 13: ...ws Repeat for the other side frame 7 Install the proper installation brackets according to the type of cabinet framed or frameless See below 4 Drill a 1 8 dia pilot hole for house wiring at A location...

Page 14: ...Draw a line on the outer edge of the bracket as shown Slide the bracket towards the center of cabinet and align side edge to marked line keeping the rear end edge leaning on the wall Use a pencil to...

Page 15: ...holding the hood run the house power cable into the hood through the strain relief previously installed in step 6 on page 10 4 Unhook the rear holes from the brackets and hang the hood using its 2 rec...

Page 16: ...rts bag Insert 2 screws per side in the slots as shown in insets on illustration below 8 For frameless cabinet secure the hood to the cabinet using 4 no 8 x 5 8 round head wood screws included in part...

Page 17: ...not included VERTICAL DUCT ACCESS HOLE 1015 16 5 5 CENTER LINE HOOD MOUNTING SCREWS 4 ELECTRICAL ACCESS HOLE IN CABINET BOTTOM WOOD SHIMS RECESSED BOTTOM CABINETS ONLY CABINET FRONT 3 4 1 1 7 16 12 47...

Page 18: ...od back towards wall until mounting screw heads are engaged in narrow end of keyhole slots in top of hood While holding the hood tighten screws securely Attach power cable to the hood using the strain...

Page 19: ...abs on inner top of hood are engaged in their corresponding slots in wiring cover Also take care not to pinch wires while reinstalling wiring cover SCREW 2 Reinstall wiring cover and attach it to the...

Page 20: ...BK O R FAN MOTOR BN BN W G Y R Low BK High W 120 V AC Line Neutral Ground BK BK Motor Switch Light Switch BL W W BK BK COLOR CODE BK BL BN BN W BLACK BLUE BROWN BROWN WHITE G Y O R W GREEN YELLOW ORAN...

Page 21: ...unted to J10 on back of control board J1 Transformer J2 Power Motor 5 4 3 2 1 5 4 3 2 1 6 7 Control Board R R BL BL BK W BK BK W G Y R Low O Medium BK High W 120 V AC Line Neutral Ground G Y W BK O R...

Page 22: ...CLUDING 4 METAL SCREWS NO 8 18 X 1 2 6 ROUND HEAD NO 8 X 5 8 WOOD SCREWS 6 NO 8 X 1 2 COUNTERSUNK WOOD SCREWS 1 1 S97020466 NON DUCTED FILTER TYPE XC SET OF 2 NON DUCTED INSTALLATION ONLY 1 1 S9952758...

Page 23: ...CREWS 1 S97020452 WIRE HARNESS 1 1 1 S98011637 WIRING COVER 1 1 1 S97020360 PARTS BAG INCLUDING 4 METAL SCREWS NO 8 18 X 1 2 6 ROUND HEAD NO 8 X 5 8 WOOD SCREWS 6 NO 8 X 1 2 COUNTERSUNK WOOD SCREWS 1...

Page 24: ...ct or replacement parts to you at no charge You are responsible for all costs for removal reinstallation and shipping insurance or other freight charges incurred in the shipment of the Product or part...

Page 25: ...Num ro de s rie 99045657 004D WWW VENMAR CA WWW VENMAR CA HOTTE DE CUISINI RE S ries VCQDD1 et VCQSEN1 MANUEL D INSTALLATION D UTILISATION ET D ENTRETIEN...

Page 26: ...allation par une personne EZ1 12 14 Installation de la hotte avec supports EZ1 15 16 Installation standard 17 Installation de la hotte installation standard 18 Branchement lectrique 19 Installation de...

Page 27: ...ons et aux standards de s curit des manufacturiers d quipement de chauffage tel qu ils sont publi s par la National Fire Protection Association NFPA et l American Society for Heating Refrigeration and...

Page 28: ...naissez le fonctionnement B Le feu est petit et limit l endroit o il a d but C Les pompiers ont t avis s D Vous pouvez combattre le feu en ayant acc s une sortie de secours Tir es du Kitchen Fire Safe...

Page 29: ...itesse de ventilateur est activ e un bip se fait entendre et un ou des t moins DEL s allument pour indiquer la vitesse choisie DEL du bas pour la BASSE vitesse DEL du bas et centrale pour la vitesse M...

Page 30: ...e solution d eau chaude et de d tergent NETTOYAGE DE L ACIER INOXYDABLE faire Laver r guli rement les surfaces l aide d un chiffon propre imbib d eau chaude et de savon doux ou de d tergent liquide va...

Page 31: ...SOFFITE DE 18 PO MIN 24 PO MAX AU DESSUS DE LA SURFACE DE CUISSON ARMOIRE CONDUIT DE 3 PO X 10 PO POUR VACUATION HORIZONTALE CAPUCHON DE MUR CAPUCHON DE TOIT CONDUIT DE 3 PO X 10 PO OU 7 PO ROND POUR...

Page 32: ...LA HOTTE 2 SUPPORTS D INSTALLATION POUR ARMOIRE AVEC FOND EN RETRAIT 2 SUPPORTS D INSTALLATION POUR ARMOIRE AVEC FOND R GULIER 1 GABARIT POUR CONDUITS IMPRIM SUR LES DEUX C T S COMPOSANTS EZ1 LES SUPP...

Page 33: ...ulant 3 D tacher les supports EZ1 de l int rieur de la hotte en coupant leur attache autobloquante Retirer les deux vis retenant l adaptateur volet la hotte Retirer l adaptateur volet de l int rieur d...

Page 34: ...ion lectrique du dessus c blage vertical ou de l arri re de la hotte c blage horizontale Installer un serre fils appropri de 1 2 po de diam tre non inclus 7 Retirer les 3 vis retenant la plaque couvra...

Page 35: ...O RONDE RETIRER AUSSI L OUVERTURE PR AMORC E VERTICALE OUVERTURE PR AMORC E VERTICALE DE 3 PO X 10 PO OUVERTURE PR AMORC E HORIZONTALE DE 3 PO X 10 PO FIGURE 1 A PLAQUE POUR CONDUIT ROND DE 7 PO VIS F...

Page 36: ...ne installation sous une armoire fond en retrait utiliser les lignes pour mesurer l paisseur du d calage caus par le mur de l armoire et plier le gabarit en cons quence To be translated in Spanish P C...

Page 37: ...ter l op ration pour l autre c t de l armoire 7 Installer les supports d installation appropri s selon le type d armoire fond en retrait ou fond gal Voir ci dessous 4 Percer un avant trou de 1 8 po d...

Page 38: ...e le mur Tracer une ligne le long du rebord externe du support tel qu il est illustr Glisser le support vers le centre de l armoire et aligner ses c t s ext rieurs sur la ligne trac e en gardant l ext...

Page 39: ...hotte passer le c ble d alimentation lectrique dans la hotte travers le serre fils install pr c demment l tape 6 en page 10 4 D crocher les trous arri re de la hotte des supports et accrocher la hott...

Page 40: ...dans le sac de pi ces Ins rer deux 2 vis par c t dans les fentes tel qu il est d montr dans les m daillons de l illustration ci dessous 8 Pour une armoire fond gal fixer la hotte l armoire l aide de...

Page 41: ...TION LECTRIQUE DANS LE DESSOUS DE L ARMOIRE CALES DE BOIS SEULEMENT POUR ARMOIRES BASE EN RETRAIT DEVANT DE L ARMOIRE 3 4 PO 1 PO 1 PO 7 16 PO 12 PO 47 16 PO DESSOUS DE L ARMOIRE 12 PO TROU POUR CONDU...

Page 42: ...z la hotte vers le mur de mani re engager la t te des vis dans la partie troite des trous en forme de serrure du dessus de la hotte Tout en retenant la hotte serrer les vis fermement Fixer le fil d al...

Page 43: ...remise en place du couvercle LANGUETTES DU DESSUS INTERNE DE LA HOTTE ENGAG ES DANS LES FENTES DU COUVERCLE DU COMPARTIMENT LECTRIQUE VIS 1 Connecter le c ble lectrique de la maison avec les fils de...

Page 44: ...limentation DEL N N V J R Basse N Haute BLA Ligne Neutre Mise la terre CODE DES COULEURS BLA BLE BR BR BLA BLANC BLEU BRUN BRUN BLANC N O R V J NOIR ORANG ROUGE VERT JAUNE Commutateur d clairage Commu...

Page 45: ...rri re de la carte lectronique J1 Transformateur J2 Alimentation Moteur 5 4 3 2 1 5 4 3 2 1 6 7 Carte lectronique R R BLE BLE N BLA N N BLA V J R Basse O Moyenne N Haute BLA 120 V CA V J BLA N O R BR...

Page 46: ...SAC DE PI CES COMPRENANT 4 VIS M TAUX N 8 18 X 1 2 PO 6 VIS BOIS T TE RONDE N 8 X 5 8 PO 6 VIS T TE FRAIS E N 8 X 1 2 PO 1 1 S97020466 FILTRES DE RECIRCULATION TYPE XC ENSEMBLE DE 2 INSTALLATION SANS...

Page 47: ...S98011637 COUVERCLE DU COMPARTIMENT LECTRIQUE 1 1 1 S97020360 SAC DE PI CES COMPRENANT 4 VIS M TAUX N 8 18 X 1 2 PO 6 VIS BOIS T TE RONDE N 8 X 5 8 PO 6 VIS T TE FRAIS E N 8 X 1 2 PO 1 1 1 S97020466...

Page 48: ...e ou de tous autres frais de transport pour l envoi du produit ou de la pi ce la Soci t Si vous devez envoyer le produit ou la pi ce la Soci t tel que la Soci t vous l indiquera vous devrez l emballer...

Reviews: