background image

 

8

After having installed the hotplate, the GPO must always be in an accessible position. 

   

Wiring diagram

 

 

 

4. Gas Connection 

Install in accordance with relevant gas standards and/or codes of practice applicable.   

Connect the elbow fitting to the appliance gas manifold connection, and check that seals between the elbow and 

manifold connection are in place and in good condition.   

 

For Natural gas: connect the natural gas appliance regulator (pictured opposite) with integral test point using 

approved gas thread tape or compound to the elbow fitting.   

 

For Universal LPG: change the natural gas regulator to LPG set by adjusts the 

spring to make sure the outlet pressure be set at 2.75kPa.   

 
 

Ensure the supply connection point, test point and natural gas regulator adjustment 

screw (for Natural gas installation) are accessible for testing and/or adjustment with the 

hotplate in the installed position.   

Where a flexible hose assembly is used, ensure it is approved to 

AS/NZS 1869, Class B. Any hose assembly used must be restrained 

from accidental contact with the flue outlet of an under bench oven. 

This hose assembly shall be suitable for connection to a fixed 

consumer piping outlet located as follows: 

Hotplates at a point 800 mm to 850 mm above the floor and in the 

region outside the width of the appliance to a distance of 250 mm. 

 

After connecting to gas, check for leaks using soapy solution, never a 

naked flame.   

 

Fit the duplicate data plate (supplied in separate bag) on a surface adjacent to the hotplate, for example, the 

inside of the cupboard door so it is clearly visible for any service technician.   

 

SETTING THE GAS PRESSURE:   

Fit a manometer with a 6 mm rubber hose to the test point on the regulator (for natural gas).   

Light Triple Ring and Auxiliary burner on and adjust test point pressure to 1.00 kPa. Turn the two burners off and 

on again and recheck the pressure is same as set previously or adjust as required.   

TEST FOR CORRECT OPERATION:   

After installation and adjusting burner pressure using test point, each burner ignition and operation must be 

tested individually and with all burners operating. This testing must be done by the installer before leaving. 

 

Inlet connection region for flexible hose

 

 

Summary of Contents for VCG64

Page 1: ...venini com au user manual 2 year warranty VCG64 60cm Gas Cooktop...

Page 2: ...l sensory or mental capabilities or their inexperience or ignorance are not able to use the device safely should not use this device without supervision or instruction by a responsible person This app...

Page 3: ...er connecting to gas check for leaks using soapy solution never a naked flame Where a flexible hose assembly is used ensure it is approved to AS NZS 1869 Class B 10mm diameter and no more than 1 0metr...

Page 4: ...HS604B G2CI GFC60 VGF60 1R 2SR 1A With 2 types for option Front LPG 27 5MJ h NG 26 0MJ h 3 GH614AS G2CI 1W 2SR 1A With 2 types for option Right LPG 30 5MJ h NG 29 5MJ h 4 GH614BS G2CI 1R 2SR 1A With 2...

Page 5: ...s Screws ST4 2x24 4 pcs LPG Injectors 4 pcs Elbow Washers 1 Elbow 3 washers Natural gas regulator 1 Technical Specifications Model Product Dimensions h x w x d mm Cut out Size w x d mm App x net weigh...

Page 6: ...mm Horizontal surfaces adjacent the hob less than or equal to the hob height Ensure there is sufficient clearance to fit the regulator and or flexible hose connection with the hotplate in the install...

Page 7: ...ame for correct operation If burner is placed correctly it will not rotate on its supports The Triple Ring Wok burner diagrams below does not fit over the igniter or thermocouple but must be placed on...

Page 8: ...st be restrained from accidental contact with the flue outlet of an under bench oven This hose assembly shall be suitable for connection to a fixed consumer piping outlet located as follows Hotplates...

Page 9: ...1 0kPa ADJUSTED FOR ULPG 2 75KPa NOZZLES DIAMETER mm Gas consumption MJ h NOZZLES DIAMETER mm Gas consumption MJ h WOK 1 70 13 0 WOK 0 98 13 0 Rapid 1 40 9 5 Rapid 0 90 10 0 SEMI RAPID 1 10 6 0 SEMI...

Page 10: ...rsist refer to the TROUBLESHOOTING section of these instructions If power is not available light a match or similar then turn the gas control knob for the burner to be lit to the High Flame setting On...

Page 11: ...Note S Ignition pin T Thermocouple Use a cotton bud tooth brush or some other item to clean out any incrustations or dirt from the four holes marked H The spark gas is 4 6mm Replace burners and ensure...

Page 12: ...circuit breaker Loose sparker cable Call authorised representative Burner not aligned properly Remove and re fit burner Burner not lighting when spark ignition working Gas supply off Check gas supply...

Page 13: ...venini com au...

Reviews: