background image

 

   

Connection precautions.

 

 

1. 

Disconnect the power supply before installing or maintaining the luminaire. 

2. 

It is strictly mandatory to connect the ground wire (Yellow / Green) with the ground connection of the installation. 

3. 

Do not touch the power supply when the lamp is running. 

4. 

To avoid damage, electric shock or fire, do not disassemble or replace the lamp (PCB CHIP LED). 

5. 

To avoid damage, falls, electric shock or fire, please do not modify or replace the original accessories with others that are not, 

without consulting and being authorized by Venalsol in advance. 

6. 

Only qualified personnel can replace or install the luminaire and make sure that you follow the instructions in the manual. If 

the installation is not done properly, it may cause falls, electric shock, fire or other damage. 

7. 

Disconnect the power supply if smoke comes out or produces an odor, as it could cause a fire or electric shock. 

8. 

Consult qualified personnel for the inspection and maintenance of the lamp.

 

9. 

If the luminaire's own wiring is damaged, it can only be replaced by Venalsol.

 

 

  

Applicable regulations

 

 

 

 

 

It has passed the necessary tests and verifications to obtain the CE Mark. This product complies with 

the application standards for Low Voltage (LVD) 2014/35 / EU: EN60598-1: 2015, EN60598-2-24: 2013, 

EN60598-2-1: 1989, EN62031: 2008, EN62471: 2008, EN62493: 2010 and Electromagnetic Compatibility 

(EMC) 2014/30 / EU: EN61000-3-2: 2014, EN61000-3-3: 2013, EN61547: 2009, EN55015: 2013. 

 

 

 

This symbol indicates that the product at the end of its useful life must be disposed of separately from 

other waste, since it is identified as an electrical or household appliance according to Royal Decree 

208/2005. Therefore, at the end of use, you must take care of delivering the product to a selective 

collection center or an authorized waste manager. Venalsol is registered in the National Registry of 

Electrical and Electronic Devices with registration number 3493 and is attached to a Waste 

Management System of Electrical and Electronic Devices for products with the category of "lighting 

equipment". 

 

Venalsol LED luminaires are environmentally friendly. They do not contain mercury and the electronic 

components used comply with the provisions of the RoHS  regulation transposing Royal Decree 

208/2005. 

 

 

Technical Parameters

 

 

 

 

 

Product specifications 

600W 

 

Input voltage 

AC100-277V 50/60Hz Clase I (Need grounding) 

Spectrum composition 

(P17) Seoul + Prolight Opto LED / (P17) Seoul + Prolight Opto LED 

Luminous flux 

1260µMol/s 

Light Beam Angle 

120º 

IP Rating 

IP65 

Dimensions (mm) 

454 x 244 mm 

Net weight of the luminaire 

11.9 ± 0.3kg 

 

Power factor 

0.95 

Operating temperature 

0 ~ +40°C 

Operating humidity 

15% ~ 90%RH 

Storage temperature 

-40 ~ +70°C 

 

Installation Instructions 

 

A.

 

Dimensions and installation of the suspended luminaire. 

 

 

  

PHYSICAL DIMENSIONS

 

 

           

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wiring diagram 

 

 

 

 

Brown  

Yellow/green 

Blue 

Blue  

 Dim+ 

 Dim- 

Dimensions expressed in mm 

 Brown 

244

   

IMPORTANT - DIM CONNECTION 

The luminaire can be regulated by a control signal of 1-10Vcc.

 

IN THE EVENT OF NOT USING THE

 

REGULATION, IT IS

 

RECOMMENDED TO ISOLATE 

AND SUBJECT

 

THE TERMINATIONS OF THIS

 

CONNECTION, TO AVOID CONTACT.

 

454

 

30

 