Connection precautions.
1.
Disconnect the power supply before installing or maintaining the luminaire.
2.
It is strictly mandatory to connect the ground wire (Yellow / Green) with the ground connection of the installation.
3.
Do not touch the power supply when the lamp is running.
4.
To avoid damage, electric shock or fire, do not disassemble or replace the lamp (PCB CHIP LED).
5.
To avoid damage, falls, electric shock or fire, please do not modify or replace the original accessories with others that are not,
without consulting and being authorized by Venalsol in advance.
6.
Only qualified personnel can replace or install the luminaire and make sure that you follow the instructions in the manual. If
the installation is not done properly, it may cause falls, electric shock, fire or other damage.
7.
Disconnect the power supply if smoke comes out or produces an odor, as it could cause a fire or electric shock.
8.
Consult qualified personnel for the inspection and maintenance of the lamp.
9.
If the luminaire's own wiring is damaged, it can only be replaced by Venalsol.
Applicable regulations
It has passed the necessary tests and verifications to obtain the CE Mark. This product complies with
the application standards for Low Voltage (LVD) 2014/35 / EU: EN60598-1: 2015, EN60598-2-24: 2013,
EN60598-2-1: 1989, EN62031: 2008, EN62471: 2008, EN62493: 2010 and Electromagnetic Compatibility
(EMC) 2014/30 / EU: EN61000-3-2: 2014, EN61000-3-3: 2013, EN61547: 2009, EN55015: 2013.
This symbol indicates that the product at the end of its useful life must be disposed of separately from
other waste, since it is identified as an electrical or household appliance according to Royal Decree
208/2005. Therefore, at the end of use, you must take care of delivering the product to a selective
collection center or an authorized waste manager. Venalsol is registered in the National Registry of
Electrical and Electronic Devices with registration number 3493 and is attached to a Waste
Management System of Electrical and Electronic Devices for products with the category of "lighting
equipment".
Venalsol LED luminaires are environmentally friendly. They do not contain mercury and the electronic
components used comply with the provisions of the RoHS regulation transposing Royal Decree
208/2005.
Technical Parameters
Product specifications
600W
Input voltage
AC100-277V 50/60Hz Clase I (Need grounding)
Spectrum composition
(P17) Seoul + Prolight Opto LED / (P17) Seoul + Prolight Opto LED
Luminous flux
1260µMol/s
Light Beam Angle
120º
IP Rating
IP65
Dimensions (mm)
∅
454 x 244 mm
Net weight of the luminaire
11.9 ± 0.3kg
Power factor
0.95
Operating temperature
0 ~ +40°C
Operating humidity
15% ~ 90%RH
Storage temperature
-40 ~ +70°C
Installation Instructions
A.
Dimensions and installation of the suspended luminaire.
PHYSICAL DIMENSIONS
Wiring diagram
Brown
Yellow/green
Blue
Blue
Dim+
Dim-
Dimensions expressed in mm
Brown
244
IMPORTANT - DIM CONNECTION
The luminaire can be regulated by a control signal of 1-10Vcc.
IN THE EVENT OF NOT USING THE
REGULATION, IT IS
RECOMMENDED TO ISOLATE
AND SUBJECT
THE TERMINATIONS OF THIS
CONNECTION, TO AVOID CONTACT.
∅
454
∅
30