PROGRAMMING OPTION DEFINITIONS:

CHANGING THE BATTERY:

Lock operates on a 3V lithium coin cell CR2450 battery located on back side of 

device. Remove screw located on cover of battery and replace it with new battery. 

Battery life is up to 10 years. The red LED light blinks 5 times after each operation 

when battery is low and it is possible to open and close lock for 100-150 times 

after you get the initial low battery warning.

0

Restoring factory settings: All factory default settings are restored (see program 

menu).  User  password  becomes  <1-0-1-0>  and  master  password  becomes              

<1-0-1-0-1-0>.

1

Locker mode: Factory default is Personal mode. Personal mode allows one 4-digit 

code to be entered that would remain the same code for one user. Locker mode is 

for multiple users whereby each user walks up to an open miniK10 and enters in their 

own unique code to close the lock and then to open it again. When open, next user 

enters in a new code, etc.

2 Audible volume control: All audio warnings can be turned off if mute operation is 

selected (except warning beeps).

3

Penalty  operation: Prevents tampering of lock by unauthorized people. Lock is 

blocked for 5 min if wrong password is entered three times consecutively. Factory 

default is that this feature is not active.

4 User code reset: Sets user factory default to <1-0-1-0>.

5

Service password: Lock can be opened with service password if user password is 

forgotten. Factory service default password is <1-0-1-0-1>. No programming features 

can be accessed with service password. Factory default is that this feature is not 

active.

6 Closing modes: Factory default - miniK10 does not require a password to lock. The 

other option is it can require a password to lock.

7 Door open warning: After door is open for one minute, lock gives an audible warning 

to user with 8 beeps every 5 sec to notify user that the door has been left open.

8

Resetting user password: If the lock is opened with service password (and service 

password is active), user password can be reset. (see program #5 on service 

passwords). Factory default is that the service password access does not allow the 

user password to be reset (only opens up the lock).

9

Blocking the lock: If lock opened with service password, it can be blocked from 

further user password access.This would. insure service password is only used 

to access locks for emergency lockouts. Master password access would then be 

required to set up user password again (0-1 Factory default reset). Factory default 

is that this feature is passive.

Summary of Contents for Kilitronik miniK 10

Page 1: ...unique electronic cam lock OPERATING MANUAL cabinets lockers boxes Please read this manual before using the miniK10...

Page 2: ...6 Opening With Service Password 6 Changing Service Password 6 Master Password 6 Opening With Master Password 6 Changing Master Password 6 Programming The miniK10 7 Accessing The Program Menu 7 Progra...

Page 3: ...ad 4 Lock Body 5 Closing Position 6 Knob Indicator 7 Opening Position 8 Knob 9 Mounting Nut 10 Lock Body 11 Battery Cover 12 Battery Cover Screw 13 ID Label 14 Hand Knob Frame 15 Cam 16 Cam Screw 17 C...

Page 4: ...your password OPERATING MODES The miniK10 can operate in two different modes 1 Personal Mode Fixed password The user will open lock each time with the same own password 2 Locker Mode factory default...

Page 5: ...SER PASSWORD If personal mode is selected default press and old password Press button again and enter new 4 digit user password Press button again and approve new password You will get a confirmation...

Page 6: ...n and enter new 5 digit service password Press button again and approve new password You will get a confirmation beep from lock and green LED lights will blink MASTER PASSWORD Opens lock and grants ac...

Page 7: ...Operation individual operation 1 Locker Mode Operation multiple user 2 0 Mute operation except for warnings 1 Audible operation button feedback warnings and confirmations 3 0 Penalty passive 1 Penalt...

Page 8: ...5 min if wrong password is entered three times consecutively Factory default is that this feature is not active 4 User code reset Sets user factory default to 1 0 1 0 5 Service password Lock can be op...

Page 9: ...master password Lock gives a warning beep when incorrect passwords have been entered in repeatedly Not possible for front side of lock to be opened by breaking or trying to force open lock Use CR2450...

Page 10: ...ental conditions of the product is used ATTENTION Remember to write down your passwords after programming and prior to installing lock It is not possible to open lock if it is in installed and you for...

Page 11: ...ANGING MASTER PASSWORD CHANGING USER PASSWORD Opening direction depends on which to type of door miniK10 is installed All opening illustrations depict right handed door installation Page 11 ATTENTION...

Page 12: ...in C 14 16220 Nil fer BURSA 90 224 411 10 30 90 224 411 10 31 and are trademarks of VEMUS End striyel Elektronik Ltd ti Rev 01 011 580 0425 www kilitronik com Hospitals Spa and Baths Schools In Mailbo...

Reviews: