background image

Cronotermostato

Digitale

TUO WI-FI BATTERIA

Manuale d’Uso

User Manual
DIGITAL CHRONOTHERMOSTAT

PDF

Summary of Contents for VE788600

Page 1: ...Cronotermostato Digitale TUO WI FI BATTERIA Manuale d Uso User Manual DIGITAL CHRONOTHERMOSTAT PDF ...

Page 2: ......

Page 3: ...ulation Page 66 parameters for regulation type Page 66 antifreeze temperature Page 67 adjustment of the measured temperature Page 67 modem Wi Fi NET Page 68 Wi Fi menu Page 69 minimum maximum settable temperature Page 70 activation deactivation of the keypad lock Page 70 operating hour meter Page 71 battery charge level Page 71 Q Other functions of the device Page 72 display of minimum maximum dai...

Page 4: ...uring the initial configuration this choice can however be changed by the user at any time Code Model Description VE788600 TuoWi Fi Batteria Bianco Wi Fi chronothermostat with batteries colour white VE788700 Tuo Wi Fi Batteria Nero Wi Fi chronothermostat with batteries colour black Q During installation and operation of the device it is necessary to comply with the following instructions 1 The devi...

Page 5: ...y programming updates The basic setting factory configuration requires the device to log in to the Cloud in the winter period from October 1st to April 30th once every 15 minutes in the time slot from 6 00 to 24 00 and once every hour in the time slot from 24 00 to 6 00 in the summer period from May 1st to September 30th once every 8 hours This setting should ensure the ideal compromise between bat...

Page 6: ...English 44 Tuo Wi Fi Batteria Chronothermostat User Manual DIMENSIONS CONNECTION DIAGRAM 1 12 130 85 28 ...

Page 7: ...imed operation Connection to the Vemer Cloud in progress Connection to the active Wi Fi network Configuration menu ADV advanced parameters of the device TIMER timings SET automatic operating temperatures T1 T2 T3 PROG automatic operating programs CLOCK date and time Local active operation In this status the device is disconnected from the Cloud Vemer and any change in operation must be made using t...

Page 8: ...tilation to avoid that the reading of the temperature measured by the probe is in some way offset Device installation Preliminary operations If you intend to use the device by remote control before proceeding with the installation and configuration make sure you have a Vemer account available To create a Vemer account proceed as follows 1 Install and start the Clima Wi Fi app on your smartphone or ...

Page 9: ...dule recessed box using the supplied screws B and connect the relay to the boiler or air conditioner control circuit 4 close the cover of the terminal block and tighten the sealing screw C 5 insert the batteries observing the correct polarity and taking care not to bend the contact strips D 6 reposition the display on the base first coupling the teeth on the upper side E 7 turn the display until i...

Page 10: ...he device 5 Now choose the Wi Fi network to connect the device to and enter the password be careful to digit faithfully all characters uppercase lowercase spaces digits that compose them Confirm to continue Important before proceeding make sure that the icon on the device display is still on Otherwise access the Wi Fi settings of the smartphone to manually reconnect to the iwm network 6 The device ...

Page 11: ...een the app and the device 5 Now enter the complete name of the Wi Fi network where connect the device and enter the password be careful to digit faithfully all characters uppercase lowercase spaces digits that compose them Confirm to continue Important before proceeding make sure that the icon on the device display is still on Otherwise access the Wi Fi settings of the smartphone to manually recon...

Page 12: ...t the seconds reset only Set the minutes Set the time Set the year Set the month Set the day To exit the date and time setting press the key for a long time to return to the home screen to change the settings of the summer winter time change press the key for a long time see Configuration of the summer winter time change on page 60 NOTE if the device has been configured without remote control and la...

Page 13: ...lows you to group several devices Page Devices list Main page This screen shows the TUO Wi Fi Batteria status indicates the measured temperature 25 0 C the operating mode Heating the system status red on gray off indicates the set temperature and running program name touch this area to access the program list indicates operating mode touch this area to change the operating mode heating cooling and...

Page 14: ... Copy function It is also possible to set a delay of switching by tapping on the desired time To know what a switching delay is see page 62 Modify a program to create a new program to select to modify to delete or to rename an existing program Note the padlock to the left of the name WINTER DEFAULT indicates that the program can not be modified or canceled Programs List page From the Program List s...

Page 15: ... BATTERIA modify the icon that identifies it set the themperature values TO T1 T2 and T3 NOTE the chronothermostat is compatible with Google Home and Amazon Echo By the association with Google or Amazon account is possible to interact with the device by giving voice commands by speaking to the Voice Assistant via the voice activated speaker Tuo Wi Fi Batteria settings bol on the upper right to ac ...

Page 16: ...n choosing the time zone and energy saving battery management enter the user email who will receive the alarm set temperature thresholds low battery warning and delay to activate the alarm NOTE LOCAL OPERATION When the chronothermostat keyboard is operated the device activates local operation In this way the device does not check if there are new settings on the Cloud and adjusts the temperature a...

Page 17: ...tat menu scheduled With this function you can set the frequency with which the device connects to the Cloud BASIC setting from October 1st to April 30th every 15 minutes in the time slot from 6 00 to 24 00 and every hour in the time slot from 24 00 to 6 00 from May 1st to September 30th every 8 hours CUSTOM setting to set the time interval between one connection and the other Minimum value 10 minu...

Page 18: ...le the device adjusts the temperature based on the value of T2 from 00 00 to 6 00 and from 8 00 to 17 00 T3 from 6 00 to 8 00 and from 17 00 to 21 00 T1 from 21 00 to 24 00 The values of T1 T2 and T3 can be set by the user Manual mode It allows you to use the device as a thermostat and the regulation is according to the temperature Tm Off mode It is suitable when long periods of absence are expect...

Page 19: ...c to manual operation Manual operation Tm operation Automatic operation To switch from manual to automatic operation To switch from automatic operation or manual to the one switched off and viceversa Manual operation Automatic operation Tm operation Automatic operation Off operation ...

Page 20: ...res of the automatic operation T1 T2 T3 The TIMER menu allows setting of one of the 3 timed operations The PROG menu allows you to change the programming of the automatic operating mode The ADV menu allows you to configure the general operating parameters of the device The CLOCK menu allows you to set date and time It also allows the configuration of the daylight saving time change ...

Page 21: ...vice acquires the date and time settings from the server and no settings are required If instead the device is not connected to the Wi Fi network proceed as follows To exit the date and time setting press the key once to return to the configuration menu press the key twice to exit the menu and return to the initial screen to change the settings of the summer winter time change press and hold for a ...

Page 22: ...ntified by the symbol the summer time change winter time is identified by the symbol For example in Italy the summer time starts the last LST Sunday 7 of March 03 at 2 00 o clock and the last LST Sunday 7 of October 10 at 3 00 o clock ee o r a mo You can configure the device to independently manage the summer time update The factory setting includes the passage winter time summer time 1h the last Sun...

Page 23: ...gram for one or more days of the week modify one or more existing programs by personalizing the profile that is assigning different temperature levels for one or more hours of the day How to choose a different program for the day Y If the program meets the needs press the key once to confirm and choose another day to which to assign a different program press the key twice to return to the configurati...

Page 24: ...e to set delays of 15 30 45 minutes independent for every hour of the day How to customize the profile of a Px program starting from midnight 00 00 press the keys and to assign to each hour of the day one of the 3 possible temperatures T1 T2 T3 and the key to confirm and go to the next hour to enter a switching delay for the selected hour hold down the key for a long time For more information about ...

Page 25: ...ter operation T1 off T2 23 C T3 25 C conditioning summer operation How to change the temperature values T1 T2 T3 Per uscire dalla modifica delle temperature premere una volta il tasto per tornare al menù di configurazione premere due volte il tasto per uscire dal menù e tornare alla schermata iniziale Nota sono ammessi valori di temperatura compresi tra L0 valore minimo e HI valore massimo Questi va...

Page 26: ... Timed automatic set a timing during the automatic operation to maintain this operation until the timing has elapsed At the end of the timing the device activates the off operation Off timed set a timing during off operation to maintain this operation until timing has elapsed At the end of the timing the device activates automatic or manual operation depending on which operation was active before ...

Page 27: ...posed in sequence Press the keys and to change the value of the selected parameter the key to go to the next parameter the key to exit and confirm the changes Note the device exits the menu after about 40 seconds without any key being pressed Operating mode Setting up AISC if the device is connected to a heating system winter operation Cond if the device is connected to an air conditioning system s...

Page 28: ...n the characteristics of the on off and proportional regulation logic see Regulation types on page 74 Parameters for the regulation type this menu varies depending on the chosen regulation type If the chosen regulation type is on off set the differential OIF Allowed values 0 1 C 1 C Factory value 0 3 C If the chosen regulation type is proportional set the band bndand the period PEr Allowed values ...

Page 29: ...cludes the antifreeze function in this case when the device is off no minimum temperature is guaranteed Adjustment of the measured temperature In particular installation conditions it can happen that the temperature measured by the device deviates from the average temperature present in the room In this case introduce an adjustment temperature with the AOJmenu Allowed values 5 C 5 C Factory value ...

Page 30: ... been connected to a Wi Fi network attempts to connect to the Wi Fi network with the previously saved parameters The symbol on the home screen indicates the connection status On fixed modem on and device connected to the Cloud Off modem off Blinking modem on and connection problem Field 14 indicates the cause Lan no connection to the Wi Fi network If this condition persists check that the router is...

Page 31: ...with the access point values higher than 60dB excellent signal quality values between 60dB and 90dB good signal quality values below 90dB poor signal quality which could compromise communication between the device and access point In this case move the device closer to the access point The MAC address of the device is a sequence alphanumeric that uniquely identifies a device within a network of dev...

Page 32: ... value 2 C HIis the upper limit Allowed values L0 50 C Factory value 50 C Activation deactivation of the keypad lock Under particular installation conditions for example in public buildings hotels etc it may be necessary to lock the keypad to prevent changes to the settings by unauthorized persons To activate the keypad lock set a password between 001 and 999 To deactivate the lock keep the key pr...

Page 33: ...0h Battery charge level Indicates the battery charge level as a percentage For values greater than 20 Guaranteed operation no alarm signal For values below 20 the device display flashes the Home screen of the app shows the indication replace the batteries the user receives a low battery alarm email if the function is enabled for values equal to 0 the device display flashes the app shows a popup with...

Page 34: ...sing a key the display shows the writing bLOc To unlock the keypad 1 While displaying the writing bLOc hold down any of the 4 keys for a long time until the display shows 2 Enter the correct password using the keys and and confirm with the key The keypad remains unlocked for about 45 seconds from the last press of a key after which the keypad reactivates the lock To deactivate the keypad lock see p...

Page 35: ...lay 3 when the display shows all the segments keep the key pressed until dEF appears SET SET Initial screen Configuration menu Operationmode heating winter Regulationtype on off Differential on off 0 3 C Band proportional 0 5 C Period proportional 10minutes AntifreezetemperatureOFF 6 C Adj ADJtemperature 0 C Min settabletemperature 2 C Max adjustabletemperature 50 C Hourmeteroperation 0h Automatics...

Page 36: ...nd that a low differential 0 1 C 0 2 C leads as a consequence more frequent ignitions of the system but the temperature will be more uniform than a high value 0 9 C 1 C Proportional regulation only for operation heating The proportional regulation allows to keep the ambient temperature more constant and is based on the concept of band and period The regulation band is the temperature range centere...

Page 37: ...aces digits that compose them Confirm to continue e Exit the app without entering the name and PIN serial number If it is necessary to assign control of the device to another user typical situation for example when the device is installed in a rented house and the tenants change proceed as follows 1 Disconnect the device from the old user via one of the following two alternative ways a Access the ...

Page 38: ...rement update every 20 seconds Measurement accuracy 0 5 C Temperature regulation on off with adjustable differential between 0 1 C and 1 C proportional with settable band and regulation period Operating mode heating winter or conditioning summer Automatic winter time summer time Keypad lock with password for installation in public places Wall installation or covering the box 503 Terminal block for...

Page 39: ...s area of at least 400 m2 if they measure less than 25 cm An efficient sorted waste collection for the environmentally friendly disposal of the used device or its subsequent recycling helps avoid the potential negative effects on the environment and people s health and encourages the re use and or recycling of the construction materials It is necessary to remove the batteries before the instrument ...

Page 40: ...Q Q Q Q Q 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P4 T3 Q Q Q Q Q Q Q Q Q Q Q T2 Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q T1 Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P5 T3 Q Q Q Q Q Q Q Q Q Q T2 Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q T1 Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q 0 1 2 3 ...

Page 41: ...Q Q Q Q Q Q Q 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P4 T3 Q Q Q Q Q Q Q Q Q Q Q Q Q T2 Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q T1 Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P5 T3 Q Q Q Q Q Q Q Q Q Q Q Q Q Q T2 Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q T1 Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q ...

Page 42: ...V3IS01092 011 202304 Vemer S p A I 32032 Feltre BL Via Camp Lonc 16 e mail info vemer it web site www vemer it 04 2023 ...

Reviews: