Vemer TRILLO User Manual Download Page 1

Vemer S.p.A.

I - 32032 Feltre (BL) • Via Camp Lonc, 16

Tel +39 0439 80638 • Fax +39 0439 80619
e-mail: [email protected]  -  web site: www.vemer.it 

DIMENSIONS

CONNECTION DIAGRAMS

DEFAULT SETTING

DEVICE STATUS

 

Mod.

 TRILLO

TRILLO-B

V3IS00501-013

72

6

45

87

Out
ON

SET

TRILLO

 

1

2

7

8

9

Power supply

OUT 

8 A / 250 V ~

•   The status of the device is segnalated by the bicolor led  :

 

OFF: 

 system not fed

 

BLINKING RED: 

 sim not inserted or pin code in activity

 

FIXED RED: 

 GSM field insufficient

 

FIXED GREEN: 

 starting system/network research

 

BLINKING GREEN: 

 connected to GSM network

 

QUICKLY BLINKING GREEN: 

 arriving in command (ring or sms)

 

QUICKLY BLINKING RED: 

 programming mode active

 

BLINKING YELLOw 

 connected to gsm field but low level battery (Trillo-B only)

User manual

GSM COMMUNICATION INTERFACE

Read all instructions carefully

  The communication interfaces 

Trillo

 and 

Trillo-B

 gsm technology based permit the remote 

control of the electic services by own mobile phone. The output relay canbe controlled by sending 

a text message or by ringing from an enabled number, thus saving the cost of the text message. 

 

Both the instruments offer the option of receiving a text message confirming activation.

 

Moreover, Trillo-B has a backup battery that permits to the instrument to operate for an hour in 

the case of power fail.

 SAFETY WARNINGS

During the installation and operation of the device observe the following instructions:

1)   The device must be installed by a qualifi ed person

2)   The device is aimed to be used in household premises and similar environments

3)   Do not use the device for purposes other than indicated

4)   The device must be installed in a electric closed panel well protected.

5)   A two-pole disconnect device shall be provided as part of the building installation

6)   A protection device against over-currents should be installed in the electrical system, 

upstream of the device

7)   When installing the device, carefully respect the wiring diagrams

8)   Disconnect the device from the power supply before accessing to the terminals

9)   Do not power or connect the instrument if any part of it is damaged

10) The use of a GSM device can cause interference with the functioning of electronic devices 

non-screened from radiofrequency signals (electromedical devices, pacemakers, hearing 

aids etc.)

11) In case of fault, do not service the device yourself but contact the after-sales service.

12) The device is aimed for use in place with over-voltage category III and pollution degree 2, 

as per standards EN 61010-1.

Code 

Model 

Description

VE245700 

Trillo 

GSM communication interface

VE293700 

Trillo-B 

GSM communication interface with backup battery

 TECHNICAL CHARACTERISTICS

•  Power supply: 

 

− TRILLO: 230V ac (-10% ÷ +10%) 50Hz

 

− TRILLO-B: 15÷40V dc / 11÷28V ac 50Hz

•  Consumption:  

 

− TRILLO: 30mA max

 

− TRILLO-B: 100mA max

•   Connection:

 

− cables with max 6 mm

2

 section

•  Output

 

− a bistable relay with exchange contact

 

− breaking capacity: 8(5)A / 250V ac

 

− red led for signal output status

•  Signalling device status:

 

− multicolour green/red led (only Trillo)

 

− multicolour green/red/yellow led (only Trillo-B)

•  GSM Dual Band module (900-1800 MHz)

•  SMA-F connector for external aerial (included in the box)

•   You can store up to 100 numbers

•  Operating temperature: 0 ÷ 50 °C

•  Operating humidity: 10 ÷ 90% noncondensing

•  Storage temperature: -10 ÷ +65°C

•  Protection: IP40

•  Insulation class: II 

•  Container: 4 DIN modules

•  Backup battery capacity: about 1 hour (Trillo-B only)

 INSTALLATION

•   In order for the instrument to operate, a sim card enabled for telephone traffic needs to be 

inserted in the relative slot, 

with the pin code and the answerphone deactivated

.

 

 To insert the sim card, remove the cover and use a sharp object to press the slot release 

mechanism, as illustrated in the alongside:

 

Attention.  Ensure that the power cables are disconnected before inserting/remove 

the sim card.

•  Once it has been connected, the instrument will become fully operative within around 30 

seconds, during which the instrument status LED will be a fixed green colour (the time needed 

to search for the network and initialise the instrument may vary on the basis of the GSM field 

in which the instrument is installed and the provider used).

 

Once the initialisation phase is completed, the green LED will start to flash with a frequency of 

1Hz and the instrument will be ready to receive commands via text message or a ring on the 

telephone. 

 

 

Note. If the device will be installed into a screened panel, it is possible to replace  

the antenna included in the kit with an another one with 3 meters cable.  

The longer antenna is available as optional. Ensure that the power cables are 

disconnected before replace the antenna.

 OPERATION

TURN ON/OFF INSTRUMENT (only Trillo-B) 

•   Trillo-B can be turn off without unlink the power cables simply pressing for at least 10 

seconds for the key “Set” while all leds turn off. During the pression of the key, the output 

led blinks quickly and the led   blinks green (or yellow) for the first 5 seconds and green/

red for the other 5 seconds.

 

To turn on the instrument, press the key “Set”.

RESET THE DEVICE

   The reset cancels all data and the parameters saved and restore the default parameters (see 

the relative box). 

 

To do a reset, proceed as follow:

•  

Trillo

 

Switch on the instrument and press the key “Set” shortly in 3 seconds. The led relative to 

the output will blink for few seconds.

•  

Trillo-B

 

 

Switch on the instrument and wait that the output led turn off. Then press the key “Set” 

shortly in 3 seconds. The led relative to the output will blink for few seconds.

SET THE CERTIFIED NUMBERS

   In order to use the instrument, it is necessary to begin by setting the admin number 

and the users number enabled (if any). Pressing the key “Set”

 

for a long time (at least 5 

seconds) allows you to enter the programming mode, where you can enable/disable the 

various telephone services. 

• 

Setting the admin number

 

 

After switching the instrument on and after esch reset, for the first time and having 

entered programming mode, the first telephone number that makes a call will 

automatically be configured as the admin number. The admin number can be changed 

later on by sending a text message from the current admin number with the command:

 

ADMIN 

[new admin number]    (the new admin number must be in international format 

+39…)

 

Nota. If you lose the admin number, it can only be changed by forcing an 

instrument reset. To retrieve automatically all the user numbers, see the 

section “Sim management”.

• 

Setting the user number (for admin only)

 

The user numbers can be entered/removed simply via a telephone call when the 

instrument is in programming mode. The caller’s number will be entered/removed on the 

basis of whether it is respectively not present/present in the phone book. A confirmation 

text message will be sent to the caller, indicating the number of locations occupied out of 

the total number available. Alternatively, the user numbers can be added or removed by 

sending a text message from the admin number with the commands:

 

USERADD

   [list of numbers to be added]   

 

USERDEL

   [list of numbers to be removed]   

 

The numbers to be added must be in international 39… and separated by an 

empty space between each number.

• 

Sim card managment (for admin only)

 

The certified numbers are saved in the device memory. For this, in case of reset, these 

numbers will be lose. To avoid to enter again all users numbers it is possible to create a 

backup copy in the sim card, using the follow commands:

 

STORE

  

copy in sim card all the number saved in the device

 

RESTORE

 

restore only the numbers saved with the command STORE

 

For this, we raccomand you to do a STORE when all numbers are abilitated.

COMMANDS

 

It is possible to work on the output as follows:

 

−   with the key present on the front panel

 

−   with ring from a certified number

 

−  with a sms from a certified number (without password) or not certified number (with 

password)

 

  Sms syntax

 

The structure for all the commands is:

 

[password] [separator] [command] [separator] [parameter1] [separator]..[parameterN]

 

  where:

 

  [password] 

 numerical field of a maximum of 8 figures

 

  [separator] 

 comprised of one or more space characters

 

  [command] 

 command recognised by the device

 

  [parameter..] 

 series of parameters relative to the command

  

 Password can be omitted if the command is imparted from a certified number 

(admin or user).

 

Some commands can be give from the admin number only. 

 

 Several commands may be included in one text message. In this case, the commands 

executed will only be those whose response is contained in a standard message (160 

characters). To enter numbers with the decimal separator, you need to use a full stop.

  

 The structure of a response to a command is similar to the command itself, with the 

addition of the “=” symbol to indicate the current status. For example:

 

OUTKEY BLOCK  

  OUTKEY=BLOCK

  Key function

 

 If press shortly, the key permits to command the output relay. The admin number can set 

the output action.

Password

12345678

Relay output status

OFF

ADMIN number

Undefined

USER numbers

Not defined

Caller control

Active

Automatic call answer

Disabled

Response to sms commands

Active

Forward unknown sms

Active

Advise power fail (only Trillo-B)

Active

Reviews: