ISCOM058-1708
Mod.
Sensor LED
Sensor 2LED
User manual
Movement detectors with LED headlight
Read all instructions carefully
The
Sensor LED
and
Sensor 2LED
proximity switches and are electronic switching devices
containing micro-disconnection (μ) according to EN 60669-2-1. They have an LED headlight
(single for Sensor LED, double for Sensor 2LED) that is activated when a heat source moves in
front of the device and is deactivated when no movement is intercepted, after a settable period
of elapsed time. They also have a relay for the connection of an external device (an auxiliary
headlight, an audible alarm, ...) which is activated simultaneously with the headlight.
SAFETY WARNINGS
During installation and operation of the device, comply with the following instructions:
1) The device must be installed by a skilled person, in strict compliance with the
connection diagrams
2) Do not power on or connect the device if any part of it is damaged
3) In the building where the device is to be installed, there must be a switch and a
device for protection from overloads
4) Before touching the connector terminals make sure that the wires to be connected
are not live.
Code Model Description
VE767200
Sensor LED
Movement detector 200° with LED headlight 13W
VE767300
Sensor 2LED
Movement detector 200° with 2 LED headlights 2x13W
TECHNICAL CHARACTERISTICS
• Power supply: 230V AC 50Hz
• Type of LED headlight:
- Sensor LED: 1x13W, 1000 lm
- Sensor 2LED: 2x13W, 2000 lm
- Colour temperature: 4000K
• Relay with breaking capacity of 10A / 250V AC (on resistive load)
• Maximum cables section: 2 x 1.5 mm2
• Range of brightness: 5-1000 lux
• Intervention time: from 3 seconds to 30 minutes (approximate)
• Angle of detection: 200°
• Range of detection: − frontal 12m at 20°C
− lateral 8m at 20°C
• Operating temperature: -20 °C ÷ +40 °C
• Protection degree: IP55
• Insulation: class II
INSTALLATION
• The device must be installed far from inductive loads (motors, transformers, telephone
antennas, transformer plants, industrial machinery, etc.) as especially strong magnetic
fields may alter operation. The device must also be protected from sunlight. It must not
be placed near lights, near devices that are subject to temperature changes (heating, air
conditioning). It must be located far from highly reflective surfaces.
Remove the cover by loosening the screw at the bottom. Fasten the base cover at the point
on the wall where you want to install it, at a height of 2-3 metres.
The direction of movement of the heat source must be transversal to lens of the device,
because detection occurs by means of intersection of bands. Therefore, if source moves
parallel to the bands, detection will occur at a lesser distance. The ambient temperature
also affects the sensitivity of the device. The higher the temperature, the poorer sensitivity
will be.
• The head can rotate horizontally of about 180° and vertically of about 45°. To adjust the
field of detection:
− turn the intervention time selector to the minimum and the brightness selector to (
);
− check coverage by moving inside the field of detection.
The device is also equipped with limiters of the detection area which, if applied to the lens,
make it possible to exclude one or more sectors of the field of detection.
• To adjust the brightness, turn the selector towards (
); when the ambient brightness
is as desired for operation, start turning the selector the other way, until illumination
occurs.
• To adjust the intervention time, turn the selector (
) to the desired position. You can
choose from a minimum of 3 seconds to a maximum of 30 minutes. This time is reset
each time there is an interception by the detector.
OPERATION
• At start and after each restoring of the power supply after a blackout, the sensor activates
the LED headlight and the load connected for 30 seconds, regardless of the brightness
level and the actual presence of movement in the field of detection.
• During normal operation, when the level of brightness drops below the set level, the
device sets up for detection, and signals this condition via flashing of the internal LED.
REFERENCE STANDARDS
Conformity to the EU directives:
2014/35/EU (LDV)
2014/30/EU (EMCD)
is declared with reference to harmonized standard:
EN 60598-1/EN 60598-2-1
Dimensions
Connection diagrams
Wall-mounting
A1
A2
L
P1
Sensor LED
Sensor 2LED
A1
100
135
A2
150
185
L
175
205
P1
155
170
P2
P2
175
190
A1
A2
L
P1
Sensor LED
Sensor 2LED
A1
100
135
A2
150
185
L
175
205
P1
155
170
P2
P2
175
190
A1
A2
L
P1
Sensor LED
Sensor 2LED
A1
100
135
A2
150
185
L
175
205
P1
155
170
P2
P2
175
190
Sensitivity
GREATER SENSITIVITY
direction of
movement
direction of
movement
LESS SENSITIVITY
L'
N
L
L
N
L'
N
L
230 V AC
LAMPADINA
µ
230 V AC
LAMPADA
SUPPLEMENTARE
L'
N
L
Incandescent
Non-compensated fluorescent
Compensated fluorescent
Halogen (230V)
LED
Low consumption lamp (CFL)
1000 W
500 VA
150 VA
1000 W
125 VA
250 VA
ADDITIONAL
LAMP