User manual

Movement detectors with LED headlight

Read all instructions carefully

  The 

Sensor LED

 and

 Sensor 2LED

 proximity switches and are electronic switching devices 

containing micro-disconnection (μ) according to EN 60669-2-1. They have an LED headlight 

(single for Sensor LED, double for Sensor 2LED) that is activated when a heat source moves in 

front of the device and is deactivated when no movement is intercepted, after a settable period 

of elapsed time. They also have a relay for the connection of an external device (an auxiliary 

headlight, an audible alarm, ...) which is activated simultaneously with the headlight.

 SAFETY WARNINGS

During installation and operation of the device, comply with the following instructions:

1)   The device must be installed by a skilled person, in strict compliance with the 

connection diagrams

2)  Do not power on or connect the device if any part of it is damaged

3)  In the building where the device is to be installed, there must be a switch and a 

device for protection from overloads

4)   Before touching the connector terminals make sure that the wires to be connected 

are not live.

Code Model  Description

VE767200

 

Sensor LED

 

Movement detector 200° with LED headlight 13W

VE767300

 

Sensor 2LED

 

Movement detector 200° with 2 LED headlights 2x13W

 TECHNICAL CHARACTERISTICS

•  Power supply: 230V AC 50Hz

•  Type of LED headlight:

 

- Sensor LED: 1x13W, 1000 lm

 

- Sensor 2LED: 2x13W, 2000 lm

 

- Colour temperature: 4000K

•  Relay with breaking capacity of 10A / 250V AC (on resistive load)

•  Maximum cables section: 2 x 1.5 mm2

•  Range of brightness: 5-1000 lux

•  Intervention time: from 3 seconds to 30 minutes (approximate)

•  Angle of detection:  200°

•  Range of detection: − frontal 12m at 20°C

 

 

− lateral 8m at 20°C

•  Operating temperature: -20 °C ÷ +40 °C

•  Protection degree: IP55

•  Insulation: class II

 

INSTALLATION

•  The device must be installed far from inductive loads (motors, transformers, telephone 

antennas, transformer plants, industrial machinery, etc.) as especially strong magnetic 

fields may alter operation. The device must also be protected from sunlight. It must not 

be placed near lights, near devices that are subject to temperature changes (heating, air 

conditioning). It must be located far from highly reflective surfaces.

 

Remove the cover by loosening the screw at the bottom. Fasten the base cover at the point 

on the wall where you want to install it, at a height of 2-3 metres.

 

The direction of movement of the heat source must be transversal to lens of the device, 

because detection occurs by means of intersection of bands. Therefore, if source moves 

parallel to the bands, detection will occur at a lesser distance. The ambient temperature 

also affects the sensitivity of the device. The higher the temperature, the poorer sensitivity 

will be.

•  The head can rotate horizontally of about 180° and vertically of about 45°. To adjust the 

field of detection:

 

− turn the intervention time selector to the minimum and the brightness selector to (

 

);

 

− check coverage by moving inside the field of detection.

 

The device is also equipped with limiters of the detection area which, if applied to the lens, 

make it possible to exclude one or more sectors of the field of detection.

•  To adjust the brightness, turn the selector towards (

 

); when the ambient brightness 

is as desired for operation, start turning the selector the other way, until illumination 

occurs.

•  To adjust the intervention time, turn the selector (

 

) to the desired position. You can 

choose from a minimum of 3 seconds to a maximum of 30 minutes. This time is reset 

each time there is an interception by the detector.

 OPERATION

•   At start and after each restoring of the power supply after a blackout, the sensor activates 

the LED headlight and the load connected for 30 seconds, regardless of the brightness 

level and the actual presence of movement in the field of detection.

•   During normal operation, when the level of brightness drops below the set level, the 

device sets up for detection, and signals this condition via flashing of the internal LED.

 REFERENCE STANDARDS

Conformity to the EU directives:

2014/35/EU (LDV)

2014/30/EU (EMCD)

is declared with reference to harmonized standard:

EN 60598-1/EN 60598-2-1

Dimensions

Connection diagrams

Wall-mounting

A1

A2

L

P1

Sensor LED

Sensor 2LED

A1

100

135

A2

150

185

L

175

205

P1

155

170

P2

P2

175

190

A1

A2

L

P1

Sensor LED

Sensor 2LED

A1

100

135

A2

150

185

L

175

205

P1

155

170

P2

P2

175

190

A1

A2

L

P1

Sensor LED

Sensor 2LED

A1

100

135

A2

150

185

L

175

205

P1

155

170

P2

P2

175

190

Sensitivity

GREATER SENSITIVITY

direction of

movement

direction of

movement

LESS SENSITIVITY

 

L'

N

L

L

N

L'

N

L

230 V AC

LAMPADINA

µ

230 V AC

LAMPADA

SUPPLEMENTARE

L'

N

L

 

Incandescent  
Non-compensated fluorescent

 

Compensated fluorescent

 

 

Halogen (230V)

 

LED

 

Low consumption lamp (CFL)

1000 W

500 VA

150 VA

1000 W

125 VA

250 VA