background image

User Manual

AMBIENT GAS MEMBRANE THERMOST

Read all the instruction carefully

    This thermostat is designed for automatic regulation of heating and 

conditioning systems in houses, hotels, schools, offices, workshops and many 

other environments, both domestic and industrial. It is also ideal for heating 

and air conditioning numerous industrial and civil applications.

 SAFETY WARNINGS

   During installation and operation of the device, it is necessary to comply 

with the following instructions:

1)  The device must be installed by a skilled person, in strict compliance with 

the connection diagrams

2)  Do not power on or connect the device if any part of it is damaged 

3)  After installation, inaccessibility to the connection terminals without 

appropriate tools must be granted

4)  The device must be installed and activated in compliance with current 

electric systems standards

5)  Before accessing the connection terminals, verify that the leads are not live

Code  Model  Contact Functions

VE018800

 

KLIMA 2 

NA 

-

VE019600

 

KLIMA 3 

NA + NC 

-

VE020400

 

KLIMA 3L 

NA + NC 

Power on warning lamp

VE021200

 

KLIMA SI 

NA + NC 

ON/OFF + Power on warning lamp

VE022000

 

KLIMA IN 

NA + NC 

ON/OFF

VE023800

 

KLIMA SW 

NA + NC 

Summer/Winter

VE024600

 

KLIMA 2V 

NA + NC 

2 speed + Summer/Winter/OFF

VE268900

 

KLIMA 3V 

NA + NC 

3 speed + OFF

 TECHNICAL SPECIFICATIONS

•  Free mounted single-pole mechanical thermostat

•  Setting range: +5 / +30°C

• Differential: 

Δ

 1°C

•  Capacity of the contacts:  16(2,5)A 250V ~ for models KLIMA 2 e KLIMA 3 

 

 

10(1,5)A 250V ~ for models  KLIMA 3L, KLIMA SI, KLIMA IN, 

KLIMA SW, KLIMA 2V, KLIMA 3V

•  Thermal gradient: 1°C / 15 min.

•  Sensitive element: vapour expansion lung

•  Class I equipment

•  Protection degree: IP20

•  Type of action: 1B

•  Silver contacts 1000/1000

•  Break or switching contacts

•  Pollution degree: 2 (normal)

•  Voltage pulse: 4kV 

•   Operating temperature: 0 ÷ 40°C

•   Operating humidity: 20 ÷ 90 %RH noncondensing

 INSTALLATION

  You are advised to position the thermostat as far as possible in a place that reflects the 

average temperature of the whole area. Avoid positioning it near doors, windows, sources 

of heat and in places where there is too much or too little ventilation.

 

The thermostat should be fitted at approximately 1.5 m from the ground.

1)

  The thermostat can be fitted to the flush-mounting box of the electric system (centre 

distance 60 mm) or directly to the wall (centre distance 60 mm);

2)

  Remove the knob, unscrew the screw of the cover and remove it as shown in the drawing;

3)

  a) fix the base to the wall

 

b) connect the thermostat earth by using the terminal marked with the earth symbol

 

c)  follow the wiring diagram inside the cover; fix the flexible inseparable wires to the 

relative screw terminals

 

d)  replace the cover, screws and knob.

 USER’S GUIDE

1)

  Set the temperature required by turning the knob;

2)

  To limit the setting field:

 

a) Isolate the power supply line

 

b) Remove the knob

 

c)  Insert the limit markers in the housing  

under the knob (17°C ÷ 23°C

 

d) Return the knob to its housing.

 REFERENCE STANDARDS

Conformity with EU directives:

2014/35/EU (LVD)

2014/30/EU (EMCD)

is declared with reference to the following standard:

 

EN 60730-2-9:

 Automatic electric command devices for household and similar use. 

 

Part 2: particular provisions for thermosensitive command devices.

ISCOM004-1604

Mod.

 KLIMA

DIMENSIONS

INSTALLATION

CONNECTIONS

Vemer S.p.A.

I - 32032 Feltre (BL) • Via Camp Lonc, 16

Tel +39 0439 80638 • Fax +39 0439 80619
e-mail: [email protected]  -  web site: www.vemer.it 

KLIMA 2

T

+°C

16(2,5)A 250V~

N
L

KLIMA 3

T

+°C

16(2,5)A 250V~

N
L

KLIMA 3L

T

+°C

10(1,5)A 250V~

N
L

KLIMA IN

ON

OFF

T

+°C

N
L

10(1,5)A

  250V~

KLIMA SI

ON

OFF

T

+°C

N
L

10(1,5)A

  250V~

KLIMA SW

T

+°C

N
L

10(1,5)A

  250V~

KLIMA 2V

OFF

I

II

T

+°C

N
L

10(1,5)A

  250V~

KLIMA 3V

T

+°C

III

OFF

I

II

N
L

10(1,5)A

  250V~

83,7

76,5

82,9

60

60

31

39

Note:

 

for “heating” operation 

mode, remove the cable 

terminal which is inside 

the device from terminal 

3 to teminal 2.