English
- 45 -
Dafne chronothermostat, user’s manual
- 44 -
Dafne chronothermostat, user’s manual
DEFAULT VALUES
Parameter
min
max
step
default
winter manual setpoint
2.0°C
35.0°C
0.1°C
21°C
summer manual setpoint
2.0°C
35.0°C
0.1°C
25°C
T1 winter
2.0°C
T2
0.1°C
15.0°C
T2 winter
T1
T3
0.1°C
18.0°C
T3 winter
T2
35.0°C
0.1°C
21.0°C
T2 summer
10.0°C
T3
0.1°C
23.0°C
T3 summer
T2
35.0°C
0.1°C
25.0°C
antifreeze temperature
1.0°C
10.0°C
0.1°C
6.0°C
operating mode
winter
summer
-
winter
regulation type
ON/OFF
PROP
-
ON/OFF
ON/OFF differential
0.1°C
1.0°C
0.1°C
0.3°C
proportional band
0.5°C
5.0°C
0.1°C
0.5°C
proportional period
10’
30’
10’
10’
password
0
999
1
000
(deactivated)
winter hour meter
0
1
0
summer hour meter
0
1
0
winter/summer time
ON
OFF
-
ON
winter/summer time
change
Summer:
LAST DAY7
march 02:00
Winter: LAST
DAY7 october
03:00
activation delay
0’
45’
15’
0’
timed operations
0h
99d
1h
0h