VELUX INTEGRA
®
KLF 200
4 VELUX
®
VELUX
®
5
ENGLISH
ENGLISH
Product overview
Default settings
Contents of packaging
1
Light-emitting diode
2
ETHERNET/service
(for internal use only)
3
Power supply
4
Key button
5
RESET
6
Outputs
7
Inputs
Default settings
Inputs (control)
An external control signal shorter than 1.5 second makes the VELUX
product travel to end position.
• Even inputs (2, 4, 6, 8) are used for close/down: The product travels to
end position
• Odd inputs (1, 3, 5, 7) are used for open/up: The product travels to end
position
An external control signal longer than 1.5 second makes the VELUX
product travel until the signal stops or until the product has reached end
position.
Default speed is used for all window operators including those supporting
silent mode.
As default, io-homecontrol
®
channel 3 is used for communication and no
channels or signals are blocked.
Outputs (signals)
The output relay is activated for 2 seconds when an action has been suc-
cessfully executed.
The default settings can be adjusted by using the web interface.
See enclosed instruction leaflet
B
.
Product overview
A B C D E
1 2 3 4
5 6 7 8 9 10
A B C D E
1 2 3 4
5 6 7 8 9 10
ETHERNET
ETHERNET
RESET
RESET
USB
USB
2
4
6
3
5
7
1
7