Velodyne HDL- 64E User Manual Download Page 9

6

.

w w w . v e l o d y n e . c o m

HDL-64E User’s Manual

W i r i n g  

The HDL-64E comes with a pre-wired connector, wired with power, DB9 serial, and standard
RJ-45 Ethernet connectors.The connector wires are approximately 25’ in length.  

Power

. Connect the red and black wires to vehicle power.  Be sure red is positive polarity.  THE

HDL-64E IS RATED ONLY FOR 12 VOLTS.  Any voltage applied over 16 volts could damage the
unit.  Expect the unit to draw 4-6 amps during normal usage.

NOTE:

The HDL-64E does not have a power switch.  It spins whenever power is applied.

The HDL-64E has a lockout circuit that prevents its lasers from firing at low RPMs.

Ethernet

. This standard Ethernet connector is designed to connect to a standard PC. See the

next section on usage for UDP packet formats.

Serial Interface.

The connector also features an RS-232 DB9 serial connector.  This connector

allows for a firmware update to be applied to the HDL-64E (Velodyne may release firmware
updates from time to time).  It also accepts commands to change the RPM of the unit.

Cable Diagram.

If you wish to wire your own connector, refer to Appendix B for a layout of the

wiring pins.  

O u t p u t

The HDL-64E outputs UDP Ethernet packets.  Each packet contains a data payload of 1206
bytes that consists of 12 blocks of 100-byte firing data followed by six bytes at the end of each
packet that contains a spin counter and firmware version information. Each packet can be for
either the upper or lower laser banks (called “laser blocks”) - each bank contains 32 lasers.
The packet format is as follows:

2 bytes of header info.

This header indicates whether the packet is for the upper block

or the lower block.  The upper block will have a header of 0xEEFF and the lower block
will have a header of 0xDDFF.

2 bytes of rotational info.

This is an integer between 0 and 35999.  Divide this

number by 100 to get degrees from 0.

32 laser returns broken into 3 bytes each.

Each return contains two bytes of

distance information in .2 centimeter increments, and one byte of intensity information
(0 – 255, with 255 being the most intense return). A zero return indicates no return
up to 65 meters.

2 bytes spin count (binary).

This field is incremented for each revolution. After

65,535 revolutions, the counter resets to 0.

Note:

The HDL-64E will ouput three upper block packets for every one lower block packet. This

provides more resolution when identifying objects at greater distances.

The minimum return distance for the HDL-64E is approximately three feet. 

Returns closer

than this should be ignored.

Usage

Summary of Contents for HDL- 64E

Page 1: ...HDL 64E U S E R S M A N U A L High Definition Lidar Sensor...

Page 2: ...Caution i w w w v e l o d y n e c o m HDL 64E User s Manual...

Page 3: ...stallation Overview 3 Mounting 3 Wiring 6 Usage 6 Output 6 Correction Angles 7 Controlling the Spin Rate 7 Firmware Update 7 Troubleshooting 8 Specifications 9 Appendix A Laser Correction Factors and...

Page 4: ...technology by providing exponentially more information about the surrounding environment than previously possible This guide first covers installation and wiring then addresses output packet construct...

Page 5: ...cloud than conventional designs The unit inherently delivers a 360 degree horizontal field of view FOV and a 26 8 degree vertical FOV Additionally state of the art signal processing and waveform analy...

Page 6: ...mounting options Figure 3 for side side mounting and Figure 4 for top mounting instructions Figure 2 Front and back HDL mounting illustration See Figure 2 This figure shows the HDL 64E s base plate sc...

Page 7: ...4 w w w v e l o d y n e c o m HDL 64E User s Manual Side Mounting Figure 3 Side side HDL mounting illustration Mounting Base...

Page 8: ...chment The unit need not be shock proofed it is designed to withstand standard automotive G forces The HDL 64E is weatherproofed to withstand wind rain and other adverse weather conditions The spinnin...

Page 9: ...UDP Ethernet packets Each packet contains a data payload of 1206 bytes that consists of 12 blocks of 100 byte firing data followed by six bytes at the end of each packet that contains a spin counter a...

Page 10: ...sensitive and must be CAPS The HDL64E will adopt the new spin rate Use the following serial parameters Baud 9600 Parity None Data bits 8 Stop bits 1 The HDL 64E has no echo back feature so no serial d...

Page 11: ...proper voltage should be 12 volts drawing about 3 4 amps Remove bottom cover and check inline fuse Replace if necessary Unit spins but no data Verify Ethernet wiring Verify packet output from another...

Page 12: ...view update user selectable 50 meter range for pavement 0 10 reflectivity 120 meter range for cars and foliage 0 80 reflectivity 1m points per second 0 05 miliseconds latency Class 1M eye safe 4 x 16...

Page 13: ...15 59649644 18 1 3978693300 2 0614092976 4 00 18 2 125897681 15 08695403 19 1 5130693300 4 4385907024 4 00 19 2 241097681 18 65304597 20 0 6215618777 4 0989635311 4 00 20 0 961172642 18 14350356 21 3...

Page 14: ...with 255 being the most intense reflection Six status bytes that alternate between packets The end of the packet will show either A reading showing the internal temperature of the unit You will see a...

Page 15: ...l J1 J2 D E I J F G H A B C KEY PIN 1 SERIAL CONNECTOR ETHERNET CONNECTOR P1 P1 3 J2 8 7 5 4 6 2 1 J1 EHTERNET OUT EHTERNET IN EHTERNET OUT EHTERNET IN GND 12 16VDC P5 P3 N C N C N C N C N C N C N C N...

Page 16: ...Resolution Post Lower Block Revolution Per Laser degrees Angular Resolution degrees 300 5 200000 6250 0 0576 0 1152 600 10 100000 3125 0 1152 0 2304 900 15 66667 2083 0 1728 0 3456 Notes The HDL 64E...

Page 17: ...5 Digital Drive Morgan Hill CA 95037 408 465 2800 voice 408 779 9227 fax 408 779 9208 service fax www velodyne com Service E mail service velodyne com Product E mail help velodyne com Technical E mail...

Reviews: