I n t r o d u c t i o n
This document outlines Chrysalis’ InstallAdvantage (IA) RS-232 protocol specification. This protocol indicates how IA products receive
run-time commands from devices such as Creston Universal Remote Controls.
C o m P o r t S e t u p
Use standard communications settings: Baud Rate: 9600, Data Bits: 8, Parity: None, Stop Bits: 1
I A I N a n d O U T P o r t P i n C o n f i g u r a t i o n
IA serial ports use a standard configuration that allows direct connection to a PC via a FEMALE to MALE serial cable. It uses only
three pins (Transmit, Receive, Ground).
The pin configurations are:
IN:
Pin 2 = Transmit
Pin 3 = Receive
Pin 5 = Ground
OUT:
Pin 2 = Receive
Pin 3 = Transmit
Pin 5 = Ground
R u n t i m e C o m m a n d F o r m a t
Byte Number
Byte Description
Notes
0‘#’
Header Character
1 to 3 or 4
Command and
3 to 4 ASCII characters see formats below
Parameter Data
Case sensitive - CAPS ONLY!
4 or 5
‘$’
Termination Character (required or command is ignored)