VELOCICALC 5725 Operation And Service Manual Download Page 5

 

Chapter 3

 

 

Operation 

Keypad Functions 

ON/OFF Key   

Press to turn the Model 5725 on and off. During the 

power up sequence the display will show the 

following:  Model Number, Serial Number, Software 

Revision and Last Date Calibrated.

 

Arrow (



) Keys 

Press to scroll through choices while setting a 

parameter. 

  (Enter) Key 

Press to accept a value or condition. 

Arrow (

 or 

) and 

Menu Soft Keys 

Press arrow keys to change choices while setting a 

parameter. Press the 

Menu 

soft key to select the 

Menu selections, which are Display Setup, 

Settings, Flow Setup, Data Logging and 

Calibration. 

Common Terms 

In this manual there are several terms that are used in different 

places. The following is a brief explanation of the meanings of those 

terms. 

 

Sample 

Consists of all of the measurement parameters 

stored at the same time.

 

Test ID 

A group of samples. The statistics (average, 

minimum, maximum, and count) are calculated for 

each test ID. The maximum number of test IDs is 

100. 

Time Constant 

The time constant is an averaging period. It is used 

to dampen the display. If you are experiencing 

fluctuating flows, a longer time constant will slow 

down those fluctuations. The display will update 

every second, but the displayed reading will be the 

average over the last time constant period. For 

example, if the time constant is 10 seconds, the 

display will update every second, but the displayed 

reading will be the average from the last 10 seconds. 

This is also referred to as a “moving average”. 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for 5725

Page 1: ...VELOCICALC AIR VELOCITY METER MODEL 5725 OPERATION AND SERVICE MANUAL P N 1980566 REVISION E FEBRUARY 2016 www GlobalTestSupply com uality Products Online at sales GlobalTestSupp...

Page 2: ...ension 3 Connecting to a Computer 4 CHAPTER 3 OPERATION 5 Keypad Functions 5 Common Terms 5 Menus 6 DISPLAY SETUP 6 SETTINGS 6 FLOW SET UP 6 DATA LOGGING 6 Measurements 6 Log Mode Log Settings 6 Delet...

Page 3: ...assed Be sure to provide the correct voltage and frequency which is marked on the back of the AC adapter The AC adapter will not recharge the batteries Attaching the Handle To attach the handle screw...

Page 4: ...act return measurements Kit includes instructions for usage Connecting to a Computer Use the Computer Interface USB Cable provided with the Model 5725 to connect the instrument to a computer for downl...

Page 5: ...g is a brief explanation of the meanings of those terms Sample Consists of all of the measurement parameters stored at the same time Test ID A group of samples The statistics average minimum maximum a...

Page 6: ...ings for each option and use the key to accept settings FLOW SET UP In Flow Setup mode there are 3 types Round Duct Rectangle Duct and Duct Area Use the or soft keys to scroll through the types and th...

Page 7: ...vailable LogDat2 Downloading Software The Model 5725 comes with special software called LogDat2 Downloading Software which is designed to provide you with maximum flexibility and power To install this...

Page 8: ...ibrated in the field using the CALIBRATION menu These field adjustments are intended to make minor changes in calibration to match a user s calibration standards The field adjustment is NOT intended a...

Page 9: ...e batteries or plug in AC adapter Dirty battery contacts Clean the battery contacts Velocity reading fluctuates unstable Fluctuating flow Reposition probe in less turbulent flow or use longer time con...

Page 10: ...s 40 to 113 F 5 to 45 C Storage 4 to 140 F 20 to 60 C Instrument Operating Conditions Altitude up to 4000 meters Relative humidity up to 80 RH non condensing Pollution degree 1 in accordance with IEC...

Reviews: