2. Set the Mail Settings in the system configuration as follows:
NOTE:
all necessary data can be obtained from your internet or mail
provider (POP3/SMTP server).
When the alarm is triggered, the alarm icon will appear above the displayed image as shown below:
11. FAQ
1. I do not have a network or internet connection. Can I still use the VWS2?
Yes, you can connect the
VWS2
directly to your PC or notebook for remote control and video storage purposes.
2. Can I use ISDN to connect to the VWS2?
No ; the
VWS2
can only be connected via ADSL or cable modem. It does not support ISDN connection.
However, a router that supports ISDN, RJ-45 and port forwarding, can be used with the
VWS2
.
3. What kind of frame rate can be expected?
This depends on the bandwidth and the average image size.
The formula to calculate the frame rate is: bandwidth / (8 x average image size) = number of images per second.
The average image size is: CIF: low=6Kb ; middle=9Kb ; high=12Kb ; VGA: low=24Kb ; middle=36Kb ; high=48Kb
Example: at a 512Kbs bandwidth and low CIF image quality (1 image = 6kb),
the frame rate is: 512 / (8x6) = 512 / 48 = 10.6 images/second.
12. Specifications
Video input
2 channels for both analogue and digital products, 1.0Vp-p, 75, composite, BNC
Alarm input
4 inputs
Watchdog
Yes
RS-485 port
Yes
Network interface Ethernet (10/100 Base-T)
Image compression JPEG
Video adjustment Brightness, Contrast, Saturation, Quality Level adjust
Protocols
TCP/IP, ICMP, SMTP, FTP, HTTP
Hardware
CPU: 16-bits RISC processor, 512KB Flash ROM, 8MB SDRAM, GPIO with e-mail/FTP trigger,
1 RJ-45 connector for 10/100Mbps Ethernet, LEDs to indicate link/act status
Resolution
VGA: 640x480 ; CIF: 320x240
Performance
video throughput: up to 15 (NTSC) / 12.5 (PAL) frames/sec. ; network throughput: up to 3MB/s.
Trigger & action
triggered by GPIO input, action: e-mail image to specific account or upload image to FTP site
Installation
assign static & dynamic IP address
Software upgrade from FTP-site
Security
password protection
Power
12V/500mA power