VTBAL29
V. 03 – 28/10/2015
5
©Velleman nv
6.4
Tare Function
1.
Switch on the scales.
2.
Place the tare item on the platform.
3.
Press the tare button once and wait for the display to show “0.00”.
4.
Add the net weight.
6.5
Calibration
1.
Switch on the scales.
2.
Press and hold the mode button and wait for the display to show “CAL”. The required calibration
weight will flash on the display. Put the calibration weight in the centre of the platform.
3.
Calibration is complete when the display shows “PASS”.
4.
The scales go back to the normal weighing mode.
7.
Cleaning and Maintenance
The scales do not need any particular maintenance. However, it is advisable to clean them occasionally to
keep them looking like new.
8.
Technical Specifications
capacity
40 kg
resolution
5 g
tare range
0-40 kg
operating temperature
0 °C ~ 40 °C
power supply
scales
2 x AAA batteries (R03, incl.) or 6 V AC or DC power adapter (not incl.)
dimensions
scales
200 x 200 mm
display
57 x 30 mm
Use this device with original accessories only. Velleman nv cannot be held responsible in the
event of damage or injury resulting from (incorrect) use of this device. For more info
concerning this product and the latest version of this manual, please visit our website
www.velleman.eu. The information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights reserved.
No part
of this manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise
without the prior written consent of the copyright holder.