background image

Velbus manual VMB1DM – edition 1 – rev.1.0 

 

1

 

VMB1DM 

 

Dimmer Module for 
Velbus

®

  

system 

Summary of Contents for VMB1DM

Page 1: ...Velbus manual VMB1DM edition 1 rev 1 0 1 VMB1DM Dimmer Module for Velbus system ...

Page 2: ...transformer capacitive load 5 Use with low mains halogen through a wound transformer inductive load 6 Troubleshooting 6 Low voltage connection 7 Direct control using several push buttons 7 Control via VELBUS system 8 Combination of direct push buttons and VELBUS control 9 Connection 10 Termination 10 Addressing 11 Time setting 11 Operation mode 12 Operation 13 LED indication 13 Learning mode 13 ...

Page 3: ...table through hexadecimal rotary switch moment 5s 10s 15s 30s 1min 2 min 5min 10min 15min 30min 1u 2u 5u 1dag on off Controllable by connecting several push buttons in parallel Push button input debounce 65ms Control through VELBUS Programmable without PC Easy learning process by operating the desired push buttons in the learning mode 7 different control possibilities Using push buttons turning on...

Page 4: ...ms 1s 2s of 3s which can be saved in the non volatile memory The module can react to push button messages sent over the VELBUS A modification of the dim status will be reported on the VELBUS When modifying the dim status the module will send instructions to adjust the status of the LEDs on the control modules Instructions will be accepted when calling up the module type module name module status r...

Page 5: ... electronic transformer capacitive load L H PB BUS VMB1DM 12V L N230 N115 LOAD N L 115V AC POWER MODE TIME ADDR 12VAC PRIM electronic transformer Dimmable 1 5mm2 1 5mm2 0 5mm2 1 5mm2 L H PB BUS VMB1DM 12V L N230 N115 LOAD N L 230V AC POWER MODE TIME ADDR 12VAC PRIM electronic transformer Dimmable 1 5mm 2 1 5mm2 0 5mm2 1 5mm2 Opgelet Place the MODE rotary switch on one of the following positions 0 ...

Page 6: ... E or F The electronic transformer must be short circuit and thermal protected Make sure to always connect a lamp on the transformer an unloaded transformer has an inductive behavior and could damage the dimmer This dimmer is not suited for toroidal transformers Troubleshooting The dimmer module features a non resettable fuse which will melt in case of a short circuit or overload In this case retu...

Page 7: ... button input by using the VELBUS or a combination of both possibilities Direct control using several push buttons L H PB BUS VMB1DM 12V L N230 N115 LOAD N L 230V AC POWER MODE TIME ADDR 1 5mm2 1 5mm2 0 5mm2 12V SUPPLY PUSH BUTTONS 1 5mm2 Remark Position the address on 00 to switch off the communication with the VELBUS Also erase all learnt push buttons In the other case de dimmer module will caus...

Page 8: ...30 N115 LOAD N L 230V AC POWER MODE TIME ADDR 1 5mm2 1 5mm2 0 5mm2 12V SUPPLY L H 0 5mm PAIR TWISTED BUS 2 1 5mm2 Remark For connection between the modules use twisted pair cable ex EIB 2x2x0 8mm2 UTP 8x0 51mm CAT5 or other Use minimum 0 5mm cable Connect the bus mind the polarity to the module ...

Page 9: ...2V L N230 N115 LOAD N L 230V AC POWER MODE TIME ADDR 1 5mm2 1 5mm2 0 5mm2 12V SUPPLY PUSH BUTTONS L H 0 5mm PAIR TWISTED BUS 2 1 5mm2 Remark For connection between the modules use twisted pair cable ex EIB 2x2x0 8mm2 UTP 8x0 51mm CAT5 or other Use minimum 0 5mm cable Connect the bus mind the polarity to the module ...

Page 10: ...the TERM jumper Remove the jumper in all other cases Remark If different cable wiring topologies tree star loop are used place a jumper on the end module of the longest cable only NOT on each end point MODE TIME ADDR TERM VELBUS Direct push button control 12V supply Manual control Termination Operation mode LED 230VAC N Forwarding LED Reception LED Power LED Address setting Operation mode Time set...

Page 11: ...mer or 10s dimming speed in slow on off dimmer mode 3 15 timer or 15s dimming speed in slow on off dimmer mode 4 30s timer or 30s dimming speed in slow on off dimmer mode 5 1min timer or 1min dimming speed in slow on off dimmer mode 6 2min timer or 2min dimming speed in slow on off dimmer mode 7 5min timer or 5min dimming speed in slow on off dimmer mode 8 10min timer or 10min dimming speed in slo...

Page 12: ...happened more than 5 seconds ago the lamp will turn off After the set time see TIME rotary switch has elapsed the lamp will turn off 5 or D Slow on dimmer Operating the push button will turn on the lamp gradually The time needed for the lamp to burn at full intensity depends on the rotating switch used to determine the time setting see TIME rotary switch Operating the push button while the lamp is...

Page 13: ...sh buttons switching off the lamp E1 ON Learning push buttons turning on the lamp to full intensity D1 TGL Learning push buttons turning on the lamp to full intensity or turning the lamp off C1 DIM Learning push buttons sliders activating the set mode on the module B1 UP Learning push buttons increasing the lamp s intensity A1 DWN Learning push buttons decreasing the lamp s intensity 91 ATM Learni...

Page 14: ...earning mode by resetting the dimmer module s original address When using firmware version 0735 you will be able to delete all push buttons and sliders saved into the memory of the dimmer module at once Set the address to one of the learning addresses Maintain the manual control on the dimmer module pressed for 10 seconds The relay will activate and deactivate again after 7 seconds to confirm the ...

Page 15: ...Velbus manual VMB1DM edition 1 rev 1 0 15 ...

Reviews: