Specifications & features
Specifications and features
SPECIFICATIONS*
5 Digital inputs (0= ground, 1= open). On board test buttons provided.
2 Analog inputs (0 …+5V) with attenuation and amplification option. Internal test +5V provided.
8 Digital open collector output switches (max 50V/100mA). On board LED indication.
2 Analog outputs
0 to 5V, output resistance 1K5.
PWM 0 to 100% open collector outputs
max 100mA / 40V. On board LED indication.
General conversion time: 20mS per command
Power supply through USB approx. 70mA.
Diagnostic software and communication DLL included
*Modifications and typographical errors reserved.
DIAGNOSTIC / TEST SOFTWARE
Features:
Separate output / input test
Clear all / set all function
Counter function on inputs 1 and 2 with adjustable debounce (max 2KHz depending on the total I/O load).
Analogue output with sliders
Analogue input with bar graph indication