6
ENGLISH
3. Address selection
In order to identify each module in your system it is necessary to set an unique address for each module.
This address will also be used by the PC software to scan all the addresses and to identify the modules.
0
1
Example of a valid address: “0 1”
1. Press and HOLD the ‘Menu’ button to open the extended menu.
2. Scroll through the extended menu using
↑
or
↓
buttons until the ‘’Configuration”
menu appears, select using the
→
button.
3. Scroll through the Configuration menu using
↑
or
↓
buttons until the ‘’Address”
menu appears
4. Select the Address menu using the
→
button.
5. Enter a unique address (‘01’...‘FE’) using the
↑
or
↓
button.
6. Confirm the address using the
→
button.
7. Exit the menu using the
button.
VMB1TC : ADDRESS SETTING USING THE MENU
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
↑
3
4
2
1
6
7
5
Each module on the Velbus system must have its own unique
address, write down the address for later use!
VMB1TSW / VMB1TCW
VMB1TS : ADDRESS SETTING USING THE 2 ADDR ROTARY SWITCHES.
CAUTION:
Addresses 81,91,A1, B1, C1, D1, E1, F1 & FF can NOT be used. Examples of valid
addresses: 01, 02, 03…. 0A, 0B…, 1A, 1B…
A total of 248 valid addresses can be selected for this module.
Adress setting trough Velbuslink©
Summary of Contents for VELBUS VMB1TSW
Page 17: ...17 Program step overview ENGLISH...
Page 23: ......