3. Technical Specifications
Working Voltage
12VDC via reversing light
Rated Current
12mA ~ 120mA
Detection Range / Angle
0.3m ~ 1.5m / H > 60°, V > 60°
Working Temperature
-20°C ~ 70°C
Dimensions
Control Unit
85 x 45 x 25mm
Sensor
Ø 25 x 21mm
Buzzer
60 x 42 x 16mm
Weight 279g
How To Interpret the Alarm Sounds
Stage Distance
Awareness
Alarm Sound
1
150 ~ 100cm
Safe
bi - - - - - bi - - - - - bi
2
90 ~ 50cm
Alarm
bi - - - bi - - - bi
3
40 ~ 30cm
Alarm
bi - bi - bi
4
0 ~ 20cm
Danger
bi- - - - - - - - - - - - - -
4. Connection Diagram
•
Connect the buzzer to the ALM output. There is only one way to insert the plug. Do not force.
•
Connect the power cable to the PWR input. There is only one way to insert the plug. Do not force. Connect the black cable (-)
to the mass of the vehicle (usually the chassis). Connect the +12VDC red cable (+) to the reverse light.
•
Connect each sensor to either one of the A, B, C or D inputs. There is only one way to insert the plug. Do not force.