background image

 
 
 
 
 
 

DC TO AC POWER INVERTER 

 

POWER : 300W 

PI300M 

for input voltage 12V 

PI30024

 for input voltage 24V 

User Manual 
Gebruikershandleiding
Manuel d'utilisation 
Bedienungsanleitung 

ATTENTION – OPGELET - ACHTUNG 

 

OVERLOADING THIS DEVICE OR CONNECTING IT WITH AN INDUCTIVE LOAD (e.g. refrigerator, fan, 
drill) WILL DAMAGE IT AND AUTOMATICALLY VOID THE WARRANTY !! 
 
HET TOESTEL ZAL WORDEN BESCHADIGD INDIEN U HET OVERBELAST OF ER EEN INDUCTIEVE 
BELASTING (vb. koelkast, boormachine, ventilator) OP AANSLUIT. DE GARANTIE VERVALT DAN 
AUTOMATISCH !! 
 
LA SURCHARGE DE L’APPAREIL OU LA CONNEXION D’UNE CHARGE INDUCTIVE (p.ex. ventilateur, 
réfrigérateur, perceuse) ENDOMMAGERONT L’APPAREIL ET LA GARANTIE SERA INVALIDEE 
AUTOMATIQUEMENT !! 

 

DIE GARANTIE ERLISCHT UND DER SPANNUNGSWANDLER KANN BESCHÄDIGT WERDEN, WENN SIE 
IHN ÜBERLASTEN ODER MIT EINER INDUKTIVEN LAST VERBINDEN (z.B. Kühlschrank, Lüfter, 
Bohrmaschine). 

Summary of Contents for PI300M

Page 1: ... WARRANTY HET TOESTEL ZAL WORDEN BESCHADIGD INDIEN U HET OVERBELAST OF ER EEN INDUCTIEVE BELASTING vb koelkast boormachine ventilator OP AANSLUIT DE GARANTIE VERVALT DAN AUTOMATISCH LA SURCHARGE DE L APPAREIL OU LA CONNEXION D UNE CHARGE INDUCTIVE p ex ventilateur réfrigérateur perceuse ENDOMMAGERONT L APPAREIL ET LA GARANTIE SERA INVALIDEE AUTOMATIQUEMENT DIE GARANTIE ERLISCHT UND DER SPANNUNGSWA...

Page 2: ... cable is 2m Please verify if you have chosen the right operating voltage for both input and output 3 OPERATION When connected to an appliance remember to turn on the inverter before turning on the appliance If the buzzer sounds during operation this indicates that the battery voltage is very low and that the inverter will be disconnected in 5 minutes power switch AC output socket voltage indicato...

Page 3: ...stranded with a dead battery To avoid over discharging the battery it is advisable to let your engine run for 10 to 20 minutes after every 2 3 hours of using the AC inverter This allows your vehicle s battery to recharge Please remember to connect the wire to the terminal and the wire to the terminal if you choose to use an adapter for a direct connection between the AC inverter and the battery te...

Page 4: ... not you need this terminal Always use heavy duty yellow and green wiring for this connection In a stationary land based installation the earthing terminal should be connected to a metal earthing stake driven into the ground to a minimum depth of 1 2m One of the battery terminals preferably the negative one should also be connected to the earthing stake if the battery system powering the inverter ...

Page 5: ...e the AC output voltage you must use an AUTHENTIC RMS VOLT METER Using any other type of voltage measuring device will result in an AC voltage reading that is up to 20 to 30 volts lower than the rated value The reading will only be accurate when using an authentic RMS voltmeter 10 VENTILATION IMPORTANT During operation make sure the fan keeps revolving Check the inverter for possible malfunctions ...

Page 6: ...e power at once B disconnect all units C check the connected devices D use the units again as soon as any problems concerning the connected devices have been solved When in use for a prolonged period of time the AC output may suddenly be cut off although the battery voltage is still very strong This may be caused by excessive temperatures If this happens please proceed as follows A Switch off the ...

Page 7: ...tput wave modified sine wave Efficiency 90 typical No load current 0 65A Input current at 100 load 29 5A for a 12V inverter 16A for a 24V inverter Output current at 100 load 1 266A Battery low alarm shutdown 10 5 0 5VDC for 12V input 21 1VDC for 24V input Overheating protection 55 5 C Dimensions 232 x 104 x 58mm Weight 0 9kg Power switch DC input ON OFF control 15 NOTE All specifications are typic...

Reviews: