Velleman PI150BN Manual Download Page 5

PI150W // 12V & 24V                                                                             VELLEMAN

 

 

6. SPECIAL RECOMMENDATIONS 
 
Unplug the AC inverter when not in use or when starting the vehicle's motor. 
 
If the AC inverter makes a beeping sound : switch off your appliance, unplug the inverter 
and restart your vehicle's engine. The beeping sound is simply the battery-low indication, 
warning you that the voltage of your battery is getting low. Your inverter will shut down 
automatically if you do not restart your engine and continue to use your inverter. This will 
leave your vehicle's battery at about 10.5VDC (12V-version) / 21VDC (24V-version), 
enabling you to start your engine and resume operation of the inverter. It also eliminates 
the possibility of being stranded with a dead battery. 
 
To avoid over-discharging the battery, it is advisable to let your engine run for 10 to 20 
minutes after every 2-3 hours of using the AC inverter. This allows your vehicle's battery 
to recharge. 
 
Please remember to disconnect the AC inverter before connecting the battery charger in 
order to replenish your battery. Failure to disconnect the inverter prior to connecting a 
charger may result in an input spike that will damage the inverter. 
CONNECTING THE INVERTER'S INPUT TO A BATTERY CHARGER WILL VOID THE 
WARRANTY AND MAY DAMAGE THE INVERTER. 
 
Make sure the voltage never exceeds 15VDC (12V-version) or 30VDC (24V-version). 
CONNECTING THE INVERTER TO A DC POWER SOURCE SUPERIOR TO 15VDC 
(12V-version) or 30VDC (24V-version) WILL VOID THE WARRANTY AND MAY 
DAMAGE THE INVERTER. THE INVERTER WILL BE SHUT DOWN 
AUTOMATICALLY. 
 
Pay attention when connecting a device to a PI. The manuals of many devices list the 
nominal power and NOT the startup power. The PI’s are protected against overload and 
this can cause the connected devices to start up with difficulty or not at all. Read the 
manual of the device to know the peak power or consult the manufacturer. 
The PI of the type ...MN/...BN has a modified sine output (viz. square wave). Read the 
manual of your PI. This means that a 150W device may experience difficulties starting up 
or may not work at all when connected with e.g. a PI150…N. 

 
7. ADDING EXTENSION CORDS 
 
We recommend that the buyer refrain from using an extension cord between the 
DC power source and the inverter's DC input. Connecting an extension cord to the 
DC input will create a voltage drop which, in turn, entails reduced efficiency. 
Instead, we recommend using an extension cord to link the AC output and the AC 
appliance. You can use up to 100ft (30m) of high-quality extension cord. A longer 
cord may result in reduced power. 

Summary of Contents for PI150BN

Page 1: ...et des piles éventuelles parmi les déchets ménagers il doit arriver chez une firme spécialisée pour recyclage Vous êtes tenu à porter cet appareil à votre revendeur ou un point de recyclage local Respectez la législation environnementale locale Si vous avez des questions contactez les autorités locales pour élimination A los ciudadanos de la Unión Europea Importantes informaciones sobre el medio a...

Page 2: ...ADIGD INDIEN U HET OVERBELAST OF ER EEN INDUCTIEVE BELASTING vb koelkast boormachine ventilator OP AANSLUIT DE GARANTIE VERVALT DAN AUTOMATISCH LA SURCHARGE DE L APPAREIL OU LA CONNEXION D UNE CHARGE INDUCTIVE p ex ventilateur réfrigérateur perceuse ENDOMMAGERONT L APPAREIL ET LA GARANTIE SERA INVALIDEE AUTOMATIQUEMENT SOBRECARGAR EL APARATO O CONECTAR UNA CARGA INDUCTIVA p ej ventiladores refrige...

Page 3: ... the cigarette plug if the blackout indicator is not lit during operation Replace a blown fuse with an identical one Please refer to 13 SPECIFICATIONS 4 OUTPUT CAPACITY The inverter will switch off automatically if the total wattage of the electrical appliances exceeds the inverter s output capacity This will also happen if the temperature of the inverter exceeds 55 C due to pro longed use 1 DESCR...

Page 4: ...he inverter The buzzer will sound when the battery voltage is very low indicating that the inverter will be disconnected in a couple of minutes In case of overload the inverter will automatically try to engage the soft start mode until the user diminishes the load and the appliance second Turn the inverter on first ...

Page 5: ...E INVERTER S INPUT TO A BATTERY CHARGER WILL VOID THE WARRANTY AND MAY DAMAGE THE INVERTER Make sure the voltage never exceeds 15VDC 12V version or 30VDC 24V version CONNECTING THE INVERTER TO A DC POWER SOURCE SUPERIOR TO 15VDC 12V version or 30VDC 24V version WILL VOID THE WARRANTY AND MAY DAMAGE THE INVERTER THE INVERTER WILL BE SHUT DOWN AUTOMATICALLY Pay attention when connecting a device to ...

Page 6: ...m radius These precautions are necessary to protect the device against overheating 10 CAUTION In case of trouble with the AC output e g short circuit overload etc the protection circuit will automatically cut off the output In such cases A switch off the power at once B disconnect all devices C check the connected devices D you can use the devices again as soon as the problems have been solved Sto...

Page 7: ...without prior notice WARNING DO NOT DISASSEMBLE THIS DEVICE AS DOING SO MAY CAUSE HAZARDOUS VOLTAGES RETURN THIS DEVICE TO THE DEALER IN CASE OF TROUBLE 13 SPECIFICATIONS DC input voltage DC 10 15V 12V DC 20 30V 24V Output power 150W Output power surge 450W Battery high shutdown 15 5 0 5V 12V 30 1V 24V Battery low alarm 10 5 0 5V 12V 21 1V 24V Battery low shutdown 10 0 5V 12V 20 1V 24V Short circu...

Page 8: ...stroomuitvalindicator niet brandt terwijl u de inverter gebruikt Vervang een gesprongen zekering door een identiek exemplaar Lees 13 SPECIFICATIES 4 UITGANGSVERMOGEN De inverter wordt automatisch uitgeschakeld indien de totale wattage van de elektrische apparaten het uitgangsvermogen van de spanningsinverter overstijgt Hetzelfde geldt indien de temperatuur van de inverter door te intensief gebruik...

Page 9: ...zer weerklinkt wanneer de batterijspanning zeer laag is Dit wijst erop dat de inverter binnen enkele minuten automatisch zal worden uitgeschakeld Bij overbelasting zal het toestel automatisch proberen de soft start mode in te schakelen zolang u de belasting niet heeft verminderd en dan pas het toestel Eerst inverter inschakelen ...

Page 10: ... BATTERIJLADER Zorg ervoor dat de spanning nooit de 15VDC 12V versie of 30VDC 24V versie overschrijdt DE GARANTIE WORDT ONGELDIG EN DE INVERTER KAN WORDEN BESCHADIGD INDIEN U HEM AANSLUIT OP EEN DC VOEDINGSBRON DIE KRACHTIGER IS DAN 15VDC 12V versie of 30VDC 24V versie DE INVERTER WORDT DAN AUTOMATISCH UITGESCHAKELD Let op wanneer u een toestel aansluit op een PI Bij vele toestellen wordt het nomi...

Page 11: ...zijn nodig om het toestel te beschermen tegen oververhitting 10 WAARSCHUWING Het beveiligingscircuit zal de AC uitgang automatisch afsnijden in geval van problemen zoals bv kortsluiting of overbelasting In zo n gevallen A inverter uitschakelen B alle verbindingen verbreken C de apparaten controleren D zodra de problemen opgelost zijn kunt u de apparaten opnieuw gebruiken Bewaar de inverter altijd ...

Page 12: ...T MET GEVAARLIJKE SPANNINGEN EN U MAG HET DUS NIET ZELF DEMONTEREN RAADPLEEG UW HANDELAAR IN GEVAL VAN PROBLEMEN 13 SPECIFICATIES DC ingangsspanning DC 10 15V 12V DC 20 30V 24V Uitgangsvermogen continu 150W Uitgangsvermogen piek 450W Uitschakeling bij te hoge ingangsspanning 15 5 0 5V 12V 30 1V 24V Batterij laag alarm 10 5 0 5V 12V 21 1V 24V Uitschakeling door zwakke batterij 10 0 5V 12V 20 1V 24V...

Page 13: ...si l indicateur de panne d électricité n est pas allumé pendant l usage de l inverseur Remplacez un fusible sauté par un exemplaire identique Lisez 13 SPECIFICATIONS 4 PUISSANCE DE SORTIE L inverseur se débranchera automatiquement si la puissance en watts des appareils électriques dépasse la puissance de sortie de l inverseur La même règle s applique lorsque la température dépasse 55 C à cause d u...

Page 14: ...marche quand la tension de l accu ne suffit plus pour alimenter l inverseur Par conséquent l inverseur sera automatiquement désactivé dans les 5 minutes En cas de surcharge l appareil essaiera automatiquement d activer le mode soft start tant que l utilisateur ne diminue pas la charge et puis l appareil Activez d abord l inverseur ...

Page 15: ...S CONNECTEZ L ENTREE DE L INVERSEUR A UN CHARGEUR D ACCUS La tension de l accu ne peut pas dépasser 15VCC version 12V 30VCC version 24V LA GARANTIE SERA INVALIDEE ET L INVERSEUR PEUT ETRE ENDOMMAGE SI VOUS LE CONNECTEZ A UNE SOURCE D ALIMENTATION DEPASSANT 15VCC version 12V 30VCC version 24V DANS CE CAS L INVERSEUR SERA DESACTIVE AUTOMATIQUEMENT Faites attention lorsque vous connectez un appareil ...

Page 16: ...r l appareil contre la surchauffe 10 AVERTISSEMENTS Le circuit de protection coupera la sortie CA automatiquement lors de problèmes comme p ex les courts circuits ou la surcharge Dans un cas pareil il faut A interrompre l alimentation tout de suite B couper toutes les connexions C contrôler les appareils D rebrancher les appareils dès que les problèmes sont résolus Stockez l inverseur dans un envi...

Page 17: ...MONTER L APPAREIL A CAUSE DU RISQUE DE TENSIONS DANGEREUSES RAMENEZ L APPAREIL AU POINT DE VENTE EN CAS DE PROBLEMES 13 SPECIFICATIONS Tension d entrée CC CC 10 15V 12V CC 20 30V 24V Puissance de sortie en continu 150W Puissance de sortie crête 450W Désactivation en cas d une tension d entrée trop élevée 15 5 0 5V 12V 30 1V 24V Alarme accu faible 10 5 0 5V 12V 21 1V 24V Désactivation en cas d accu...

Page 18: ...urante el uso del convertidor controle el fusible del conector mechero Reemplace el fusible fundido por uno del mismo tipo Véase 13 ESPECIFICACIONES 4 POTENCIA DE SALIDA El convertidor se desactivará automáticamente si la potencia de salida total de los aparatos eléctricos utilizados sobrepasa la potencia de salida del convertidor Se desactivará también si las temperaturas sobrepasan los 55 C por ...

Page 19: ...i la tensión de la batería se vuelve demasiado débil para alimentar el convertidor Por lo tanto el convertidor se desactivará automáticamente después de unos 5 minutos En caso de sobrecarga el aparato intentará activar automáticamente el modo de arranque suave Soft Start hasta que el usuario haya disminuido la carga Luego el aparato Primero active el convertidor ...

Page 20: ...e la tensión de batería nunca sobrepase los 15VCC versión de 12V 30VCC versión de 24V SE INVALIDARÁ LA GARANTÍA Y SE PODRÍA DAÑAR EL CONVERTIDOR SI LO CONECTA A UNA FUENTE DE ALIMENTACIÓN CC QUE SOBREPASE LOS 15VCC versión de 12V 30VCC versión de 24V EN ESTE CASO EL CONVERTIDOR SE DESACTIVARÁ AUTOMÁTICAMENTE Cuidado al conectar un aparato a un PI El manual de usuario de la mayoría de los aparatos ...

Page 21: ...ra el sobrecalentamiento 10 CUIDADO El circuito de protección desconectará la salida CA automáticamente si hay problemas p ej cortocircuitos o sobrecargas En tales casos A desconecte la alimentación inmediatamente B desconecte los aparatos C controle los aparatos D vuelva a conectar los aparatos tan pronto como se hayan resueltos los problemas Guarde el convertidor en un lugar A bien aireado B que...

Page 22: ...SAR TENSIONES PELIGROSAS EN CASO DE PROBLEMAS CONTACTE CON SU DISTRIBUIDOR 13 ESPECIFICACIONES Tensión de entrada CC CC 10 15V 12V CC 20 30V 24V Potencia de salida nominal 150W Potencia de salida de pico 450W Desactivación en caso de una tensión de entrada demasiada elevada 15 5 0 5V 12V 30 1V 24V Alarma de batería baja 10 5 0 5V 12V 21 1V 24V Desactivación en caso de batería baja 10 0 5V 12V 20 1...

Page 23: ... der Spannungsabfallindikator bei der Verwendung des Spannungswandlers nicht brennt Ersetzen Sie eine defekte Sicherung immer durch eine solche gleichen Typs Siehe 13 TECHNISCHE DATEN 4 AUSGANGSLEISTUNG Der Spannungswandler schaltet automatisch ab wenn die gesamte Versorgungsleistung der elektrischen Geräte die Ausgangsleistung des Spannungswandlers übersteigt Der Spannungswandler schaltet ebenfal...

Page 24: ...weißt es darauf hin dass die Batteriespannung sehr niedrig ist und dass der Spannungswandler innerhalb von einigen Minuten automatisch ausgeschaltet werden wird Bei Überlast wird das Gerät automatisch versuchen den Softstart Modus einzuschalten solange Sie die Last nicht verringern dann das Gerät Zuerst Spannungs wandler einschalten ...

Page 25: ...ANDLER KÖNNTE BESCHÄDIGT WERDEN WENN SIE DEN EINGANG DES SPANNUNGSWANDLERS AN DAS LADEGERÄT FÜR BATTERIEN ANSCHLIEßEN Sorgen Sie dafür dass die Spannung nie 15VDC Version 12V oder 30VDC Version 24V überschreitet DIE GARANTIE ERLISCHT UND DER SPANNUNGSWANDLER KÖNNTE BESCHÄDIGT WERDEN WENN SIE IHN MIT EINER DC STROMQUELLE ÜBER 15VDC Version 12V oder 30VDC Version 24V VERBINDEN DER SPANNUNGSWANDLER W...

Page 26: ... um das Gerät vor Überhitzung zu schützen 10 ACHTUNG Bei Problemen wie z B Kurzschluss oder Überlastung wird der Ausgang automatisch von einer Sicherheitsschaltung ausgeschaltet In solchen Fällen A schalten sie den Spannungswandler sofort aus B trennen Sie alle angeschlossenen Geräte vom Spannungswandler C überprüfen Sie die Geräte D benutzen sie die Geräte erst wieder wenn die Probleme behoben wu...

Page 27: ...IBT LEBENSGEFÄHRLICHE SPANNUNGEN REPARATUREN SOLLTEN NUR DURCH FACHLEUTE ERFOLGEN WENDEN SIE SICH BEI PROBLEMEN AN IHREN FACHHÄNDLER 13 TECHNISCHE DATEN DC Eingangsspannung DC 10 15V 12V DC 20 30V 24V Ausgangsleistung ständig 150W Ausgangsleistung Spitze 450W Ausschaltung bei zu höher 15 5 0 5V 12V 30 1V 24V Eingangsspannung Lo Bat Alarm 10 5 0 5V 12V 21 1V 24V Ausschaltung durch schwache Batterie...

Reviews: