13
Configuration
1. Push 'setup'-button repeatedly to configure either left relay (LD2 lights) or right relay
(LD3 lights).
2. Confirm your selection with a long push (LD4 flashes 3 times). The selected relay will
remain ON.
3. Push 'setup'-button a number of times, depending on the desired mode (see table). At
each press, LD1 will flash a # of times, indicating the current mode.
4. Confirm with a long push (LD4 flashes 3 times). The selected relay will turn off and the
unit is ready for use.
The unit will return to normal operation when left idle for 10s. The current mode will not
be changed.
If necessary, repeat sequence for the remaining channel.
Factory defaults: left relay-output: 0.5s timer right relay-output: 1h timer
20. Configuration of left and right relay output
flashes
Mode
1
2
3
4
5
6
7
8
9
ON/OFF
0.5s timer
5s timer
30s timer
1min timer
5min timer
15min timer
30min timer
1h timer
21. Use
Pressing a transmitter button will operate both outputs simultaniously.
Each relay will behave according to the selected mode.
In '0.5s timer'-mode, the relay will remain on for as long as the remote button is held.
In 'ON/OFF'-mode, the relay will toggle between ON and OFF every time the remote button is pushed.