background image

13 

 
 

 
 
 

17. PCB Layout

 

SK15

SK6

SK7

SK21

24VAC

LOAD1

N

1

C

VELLEMAN P8006'1

R7

D9

F2

R8

R6

D3

R9

R3

D7

F1

2.5A SLOW

LD1

R4

R2

D2

R5

L

SUPPLY

N

nc

L

L

nc

LD

LOAD

DATA

C

E

IC1

1

IC2

1

SK1

1

SK2

1

C

3

1

4

5

2

OPEN

COLLECTOR

INPUTS

LD6

D1

R1

LD7

R22

D17

R23

SK11

C

SK12

SK13

D8

SK16

LOAD2

N

SK17

LOAD3

N

SK18

LOAD4

N

SK19

LOAD5

N

SK20

N

LD2

D10

10

10

SK14

1

2

3

4

5

DANGER

HIGH

VOLTAGE

C

1

5

INPUTS

OPEN COLLECTOR

24VAC INDICATION

2.5A SLOW

2

C

SK9

SK10

4

C

5

C

SK8

3

C

C2

R11

D11

F3

R12

R10

D4

R13

IC3

1

SK3

1

LD3

D12

10

2.5A SLOW

C3

R15

D13

F4

R16

R14

D5

R17

IC4

1

SK4

1

LD4

D14

10

2.5A SLOW

C4

R19

D15

F5

R20

R18

D6

R21

IC2

1

SK5

1

LD2

D16

10

2.5A SLOW

C5

C1

SW1

SW2

SW3

SW4

SW5

2K2

2K2

PUSH BUTTON INPUTS

ZD1

ZD2

PCB Layout 

Summary of Contents for K8006

Page 1: ...computer inter face card or with IR remote control receiver K6711 Local control pushbuttons included LED power and mains indicator LED operation indicator for each channel Low voltage control circuit...

Page 2: ...VELLEMAN COMPONENTS Legen Heirweg 33 9890 Gavere Belgium http www velleman be...

Page 3: ...cutting excess leads hold the lead so they cannot fly towards the eyes Needle nose pliers for bending leads or to hold compo nents in place Small blade and phillips screwdrivers A basic range is fine...

Page 4: ...1 3 Soldering Hints 1 Mount the component against the PCB surface and carefully solder the leads 2 Make sure the solder joints are cone shaped and shiny 3 Trim excess leads as close as possible to th...

Page 5: ...Oranssi Orange Orange Orange Orange Orange Orange Oranje 3 4 Giallo Amarelo Amarillo Keltainen Gul Gul Gul Gelb Yellow Jaune Geel 4 5 Verde Verde Verde Vihre Gr n Gr n Gr nn Gr n Green Vert Groen 5 6...

Page 6: ...W q ZD2 47V 1 3W 4 Zener diode check the polarity CATHODE ZD q R2 180 1 8 1 B 9 q R3 180 1 8 1 B 9 q R4 2K2 2 2 2 B 9 q R5 2K2 2 2 2 B 9 q R6 180 1 8 1 B 9 q R7 180 1 8 1 B 9 q R8 2K2 2 2 2 B 9 q R9 2...

Page 7: ...W q LD1 3mm RED 2 q LD2 3mm RED 2 q LD3 3mm RED 2 q LD4 3mm RED 2 q LD5 3mm RED 2 q LD6 3mm RED 2 q LD7 3mm RED 2 7 LEDs Watch the polarity COLOR 2 5 LD CATHODE q SK1 10 POLE q SK2 10 POLE q SK3 10 PO...

Page 8: ...blocks Slide the terminal blocks one into each other q SK14 2 POLE wide q SK15 2 POLE wide q SK16 2 POLE wide q SK17 2 POLE wide q SK18 2 POLE wide q SK19 2 POLE wide q SK20 2 POLE wide q F1 2 5A SLOW...

Page 9: ...pacitors Check the polarity C Construction q SK21 6 POLE 12 Modular Jack SK q IC1 4N27 TIL111 or eq q IC2 4N27 TIL111 or eq q IC3 4N27 TIL111 or eq q IC4 4N27 TIL111 or eq q IC5 4N27 TIL111 or eq 13 I...

Page 10: ...6 will light Connect the 110 240V mains to the SUPPLY Neutral and Live connector LD7 will light Push button SW1 The module will be activated and the light bulb will light For dimmer timer module opera...

Page 11: ...hows a connection example Make sure your wiring complies with the local safety requirements If doubt consult a licensed technician 15 Final Connection 24VAC LOAD1 N 1 C 2 C 3 C C VELLEMAN K8006 L SUPP...

Page 12: ...which allows easy and fast connection to a control circuit 16 Interfacing with open collector outputs 24VAC LOAD1 N 1 C 2 C 3 C C VELLEMAN K8006 L SUPPLY C LOAD2 N LOAD3 N LOAD4 N LOAD5 N N 1 2 3 4 5...

Page 13: ...SK13 D8 SK16 LOAD2 N SK17 LOAD3 N SK18 LOAD4 N SK19 LOAD5 N SK20 N LD2 D10 10 10 SK14 1 2 3 4 5 DANGER HIGH VOLTAGE C 1 5 INPUTS OPEN COLLECTOR 24VAC INDICATION 2 5A SLOW 2 C SK9 SK10 4 C 5 C SK8 3 C...

Page 14: ...1 6 4 5 4N27 IC3 R11 82 0 6W D12 1N4007 C3 22u 50V D11 1N4007 R13 2K2 6W R10 82 0 6W D4 1N4148 R16 2K2 0 6W LD4 LED3RL 4 2 1 6 4 5 4N27 IC4 R15 82 0 6W D14 1N4007 C4 22u 50V D13 1N4007 R17 2K2 6W R14...

Page 15: ...15...

Page 16: ...VELLEMAN Components Legen Heirweg 33 9890 Gavere Belgium Europe Info http www velleman be Modifications and typographical errors reserved Velleman H8006IP 2001 ED2...

Reviews: