dimensions ..................................................... 138 x 67 x 30 mm
weight (with battery) ......................................................... 120 g
storage environment
temperature ................................................. -20 °C to 60 °C
humidity ............................................................ < 90 % RH
test lead probe .............................. CAT III 600 V, 10 A; L = 70 cm
IP rating ........................................................................... IPx0
9.1
DC VOLTAGE
Do not measure circuits that may contain voltages
> 500 VDC or > 500 VAC
range
resolution
accuracy
200 mV
0.1 mV
± (1.0 % rdg + 2 digits)
2 V
1 mV
20 V
10 mV
200 V
100 mV
500 V
1 V
± (1.2 % rdg + 2 digits)
Overload protection: 500 V DC or AC rms
Impedance: 1 MΩ
9.2
AC VOLTAGE
Do not measure circuits that may contain voltages
> 500 VDC or > 500 VAC
range
resolution
accuracy
200 V
100 mV
± (1.5 % rdg + 3 digits)
500 V
1 V
Average sensing, calibrated to rms of sine wave
Frequency range: 40-500 Hz
Overload protection: 500 V DC or AC rms