5. Technical Specifications 

 

Measurement Range 

-20°C ~ 270°C (-4°F ~ 518°F) 

Accuracy 

+/- (2% of rdg + 3°C/6°F) 

Ambient Temperature Measurement Range 

0°C ~ 50°C (32°F ~ 122°F) 

Resolution 1°C/1°F 
Emissivity 0.95 

Distance-to-Spot Ratio 

6:1 

Overrange Indication 

“OL” or “-OL” 

Auto Power-Off 

20s 

Power Supply 

2 x AAA battery (order code LR03C, incl.) 

Dimensions 

94 x 59 x 28mm 

Weight 75g 
 

6. Measurement Principle 

 
Non-contact thermometers detect the infrared ray of an object, focus the infrared energy of the object onto a sensor through a lens, and 
transfer the surface temperature into an electric signal. A microcomputer calculates and displays the measurement temperature on the LCD. 

The laser is only used to aim the thermometer. 
 

7. Operation 

 

 

How to Measure an Object’s Temperature 

 
Point the infrared sensor towards the object and press the SCAN button. The thermometer emits a laser beam. Read the measured 
temperature value from the LCD display. Release the SCAN button. The thermometer will automatically power off after 20 seconds. Refer to 

8. D:S Ratio” for accurate results. 
 