DVM1090                                                                                                                                                                  GB 

8

2.  Set the range switch at the desired V-range position. 
3.  Connect the test leads with the source or load under measurement. 
4.  Read the measured value from the LCD. The polarity of the red lead connection is also indicated. 
 

REMARKS 

 

• 

The LCD displays the overrange indication “1” if the measured value is too high for the range you are using. 
Select a higher range. 

• 

Place the range selector in the highest position if the value to be measured is unknown beforehand. 

 
 

5.7. Measuring 

AC 

Voltage 

 

 

WARNING

 

 
The input voltage should not exceed 700Vrms AC. Be very careful and avoid electroshocks when working with high 

voltages. 
1.  Connect the black test lead with the COM jack and the red test lead with the V jack. 
2.  Set the range switch at the desired V-range position. 
3.  Press the DC/AC button to install the AC measuring mode. 

4.  Connect the test leads with the source or load under measurement. 
5.  Read the value from the LCD. 
 

REMARKS 

 

• 

The LCD displays the overrange indication “1” if the measured value is too high for the range you are using. 
Select a higher range. 

• 

Place the range selector in the highest position if the value to be measured is unknown beforehand. 

 
 

5.8. Measuring 

DC 

Current 

 

 

WARNING

 

 
Deactivate the circuit to be tested before connecting it to the meter. 

 
1.  Connect the black test lead with the COM jack and the red test lead with the A jack for current measurements up 

to 200mA. Move the red lead to the 10A jack for measurements up to 10A. 

2.  Select the desired A-range with the range switch. 

3.  Connect the test leads in series with the load under measurement. 
4.  Read the measured value from the LCD. The measured voltage value and the polarity of the red connection are 

displayed. 

 

REMARKS 

 

• 

The LCD displays the overrange indication “1” if the measured value is too high for the range you are using. 
Select a higher range. 

• 

Place the range selector in the highest position if the value to be measured is unknown beforehand. 

• 

Respect the limit values 

 : the max. current for socket A is 200mA, the max. current for the 10A socket is 10A. 

The fuse will blow if the limit values are exceeded. 

Summary of Contents for DVM1090

Page 1: ...DVM1090 DIGITAL THERMOMETER DIGITALE THERMOMETER THERMOMETRE NUMERIQUE DIGITALES THERMOMETER MULT METRO DIGITAL User Manual Gebruikershandleiding Manuel d utilisation Gebrauchsanleitung Manual...

Page 2: ...erminals when the meter is connected to a circuit Place the range selector switch in the highest position if the value to be measured is unknown beforehand Do not measure voltages 1000V above earth gr...

Page 3: ...F position when the device is not being used Remove the batteries to keep them from leaking if the device is to be stored for a prolonged period of time 3 Front Panel Description 1 LCD display 2 L C b...

Page 4: ...ction F 200mA 250V quick acting max resistance 2 F 10A 250V quick acting Power Supply 9V battery e g 6F22 Operating Temperature 0 C to 40 C 32 to 104 F Storage Temperature 10 C to 50 C 10 to 122 F Dim...

Page 5: ...2 3 DC Current Range Resolution Accuracy 2mA 1 A 1 0 of rdg 3 digits 20mA 10 A 1 0 of rdg 3 digits 200mA 100 A 1 5 of rdg 5 digits 10A 10mA 2 0 of rdg 10 digits Overload Protection F1 F 200mA 250V fu...

Page 6: ...gits 20 F 10nF 4 0 of rdg 5 digits Overload Protection F1 F 200mA 250V fuse quick acting max resistance 2 4 2 7 Inductance Range Resolution Accuracy 2mH 0 001mH 4 0 of rdg 8 digits 20mH 0 01mH 4 0 of...

Page 7: ...ES from the display 4 2 11 Diode Range Resolution Function 1mV Read the diode s approximate forward voltage value from the display Forward DC Current 1mA Reversed DC Voltage 2 8V Overload Protection 2...

Page 8: ...ressed in for AC voltage and AC current measurements 5 4 Selecting L or C Put the button in the pressed down position for inductance and capacitance measurements The component can now be tested Put th...

Page 9: ...splays the overrange indication 1 if the measured value is too high for the range you are using Select a higher range Place the range selector in the highest position if the value to be measured is un...

Page 10: ...make sure that all capacitors are fully discharged before measuring the in circuit resistance 1 Connect the black test lead with the COM jack and the red test lead with the jack 2 Select the desired r...

Page 11: ...on socket included with the COM V A sockets Insert the inductor s pins in the and connectors of the multifunction socket REMARKS Keep in mind that precise inductance measurements are impossible in clo...

Page 12: ...suring the circuit s continuity 1 Connect the black test lead with the COM jack and the red test lead with the jack 2 Place the range switch in the desired range position 3 Connect the test leads with...

Page 13: ...est leads before replacing the fuse in order to avoid electroshocks In order to avoid unnecessary fire risks you should only use fuses with the following ratings F1 F 200mA 250mV quick acting resistan...

Reviews: