DCM266                                                                                                                                  GB

4

2.1 Function and range selector

A rotary switch is used to measurement Functions and Ranges. When the
switch is set to OFF position, the meter does not operate.

2.2 Transformer jaws

Pick up the AC current flowing through the conductor. Press the TRIGGER
to open the transformer jaws. When the finger press on the TRIGGER is
released, the jaws will close again.

2.3 Data hold

A push switch (Push ON, Push OFF. All ACA, ACV, DCV ranges with this
feature)

2.4 Input jacks

This meter has three input jacks that are protected against overload to the
limits.
During use connect the black test lead to COM jack and connect red test
lead to V 

 jack. The red test lead is depended on function selected.

The EXT jack is used for accept insulation tester unit EXT banana plugs, when
measurement insulation resistance.

Summary of Contents for DCM266

Page 1: ...DCM266 Digital Clamp meter OPERATION MANUAL GEBRUIKERSHANDLEIDING MANUEL D UTILISATEUR...

Page 2: ...ll compliance with safety standards can be guaranteed only if used with test leads supplied If necessary they must be replaced with the same model or same electronic ratings Measuring leads must be in...

Page 3: ...ulating material 1 3 Symbols 1 4 Maintenance l Before opening the meter always disconnect test leads from all sources of electric current l If any faults or abnormalities are observed the meter can no...

Page 4: ...measuring DC and AC voltage AC current resistance continuity test and insulation test Full overload protection low battery indication and over range indication are provided Transformer jaws Trigger Da...

Page 5: ...finger press on the TRIGGER is released the jaws will close again 2 3 Data hold A push switch Push ON Push OFF All ACA ACV DCV ranges with this feature 2 4 Input jacks This meter has three input jacks...

Page 6: ...insulation tester unit range switch to the 2000M position 4 Use the insulation tester unit of the test leads connect its L E input connect to being tested installation s Test installation s must be po...

Page 7: ...test lead to the V jack 2 Set the rotary switch at desired position and connect test leads across the resistor under measurement NOTE 1 If the resistance being measured exceeds the maximum value of th...

Page 8: ...RTH GROUND CAT II 600V OPERATING TEMPERATURE 0 C to 40 C 32 F to 104 F STORAGE ENVIRONMENT 10 C to 50 C 14 F to 122 F POWER SUPPLY 9V battery ACCESSORIES operating manual set of test leads LOW BATTERY...

Page 9: ...C Voltage Range Resolution Accuracy 600V 1V 1 0 of rdg 4 digits Input Impedance 9M on all ranges Overload protection 600V peak or 600Vrms AC on all ranges Frequency Range 50Hz to 500Hz Response Averag...

Page 10: ...Accessories Test leads Battery Operating manual 6 Battery replacement If the sign BAT appears on the LCD display it indicates that battery should be replaced Remove the battery cover of case Replace...