1. Introduction 

 

To all residents of the European Union 

Important environmental information about this product 

This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the 
environment. 
Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialised company for 
recycling. 

This device should be returned to your distributor or to a local recycling service. 
Respect the local environmental rules. 

If in doubt, contact your local waste disposal authorities. 

 

Thank you for buying the 

DIGITAL CALLIPER

! Read this manual carefully before bringing the device into service.  

 

2. Specifications & Functions 

 

Measuring range 

Resolution & Repeatability 

Accuracy 

0-150mm / 0-6" 

0.01mm / 0.0005" 

0.02mm / 0.0001" 

 

Data output 

Serial output for interface with host computer or printer 

Maximum measuring speed: 

1.5m/sec or 60"/sec 

Display:  

LCD, features minus sign "-", character in 6.35mm / 0.25" height for 5 digits, small digit "5" 
and "IN" indication for inch measuring unit 

Battery: 

one 1.5V silver oxide battery for one year of continuous use. 

 

Low-battery warning by flashing display. 

Operating temperature: 

0°C 

 +40°C 

Storage temperature: 

-20°C 

 +70°C 

Operating humidity: 

0 to 80% 

 

1.  ON / OFF key 
2.  METRIC / INCH change over key (true conversion) 
3.  Zero setting (resets any value to zero for reference) 
4.  Battery cover 

 

3. Maintenance Instructions 

 

1.  Keep the device and the battery compartment clean and prevent liquids from entering the electronic part to avoid damaged 

electronics. 

2.  Clean the device with petrol, lubricate the body with some clock oil. Acetone and alcohol should not be used. 

 

4. Troubleshooting 

 

Problem 

Cause 

Solution 

The 5 digits change every second 

Battery voltage is under 1.45V 

Replace battery. 

Displayed value doesn't change. 

Circuitry malfunction 

Remove the battery and put it back after 30 seconds. 

LCD shows 000.00mm / 00.000in 

One of the keys is short circuited 

Remove the cover & adjust key spring position 

Function keys do not work 

Key spring is bent or deformed 

Remove the cover & adjust key spring position 

Calliper does not measure 
accurately 

Sensor is dirty 

Remove the cover and slider assembly, clean the 
sensor with pressure air (

51kg/cm²), and clean it 

with a little petrol for dirt prevention. 

No display on LCD screen 

1) No battery contact. 
2) Battery voltage is under 1.1V. 

1)  Restore battery contact. 
2)  Replace battery 

 

5. Applications (see p. 6) 

 

For more info concerning this product, please visit our website www.velleman.eu. 

The information in this manual is subject to change without prior notice. 