Velleman-Kit K5201 Manual Download Page 2

 

5%

4K7= ( 4  -  7  -  2  -  B )

            

1%

4K7= ( 4 - 7 - 0 - 1 - 1 )

                  

COLOR= 2… 5

 

 

SF 

DK 

GB 

NL 

 

C
O
D

 

CODICE 

COLORE

 

CODIGO 

DE 

CORES 

CODIGO 

DE COL-

ORES

 

VÄRI 

KOODI 

FÄRG 

SCHEMA

 

FARVE

KODE 

FARGE

KODE 

FARB 

KODE 

COLOUR 

CODE

 

CODIFI-
CATION 
DES 
COU-
LEURS

 

KLEUR

KODE

 

C
O
D

Nero 

Preto 

Negro 

Musta 

Svart 

Sort 

Sort 

Schwarz  Black 

Noir 

Zwart 

Marrone  Castanho 

Marrón 

Ruskea 

Brun 

Brun 

Brun 

Braun 

Brown  Brun 

Bruin 

Rosso 

Encarnado  Rojo 

Punainen  Röd 

Rød 

Rød 

Rot 

Red 

Rouge  Rood 

Aranciato  Laranja 

Naranjado  Oranssi 

Orange  Orange  Orange  Orange 

Orange  Orange  Oranje 

Giallo 

Amarelo 

Amarillo 

Keltainen  Gul 

Gul 

Gul 

Gelb 

Yellow  Jaune 

Geel 

Verde 

Verde 

Verde 

Vihreä 

Grön 

Grøn 

Grønn 

Grün 

Green  Vert 

Groen 

Blu 

Azul 

Azul 

Sininen 

Blå 

Blå 

Blå 

Blau 

Blue 

Blue 

Blauw 

Viola 

Violeta 

Morado 

Purppura  Lila 

Violet 

Violet 

Violet 

Purple  Violet 

Paars 

Grigio 

Cinzento 

Gris 

Harmaa 

Grå 

Grå 

Grå 

Grau 

Grey 

Gris 

Grijs 

Bianco 

Branco 

Blanco 

Valkoinen  Vit 

Hvid 

Hvidt 

Weiss 

White 

Blanc 

Wit 

Argento 

Prateado 

Plata 

Hopea 

Silver 

Sølv 

Sølv 

Silber 

Silver 

Argent  Zilver 

Oro 

Dourado 

Oro 

Kulta 

Guld 

Guld 

Guldl 

Gold 

Gold 

Or 

Goud 

Summary of Contents for K5201

Page 1: ...n selection with rotary switch þ Adjustable effect speed þ External oscillator input þ Daisy chain units to create even bigger light shows þ Special setting for two linked units to create 14 channel operation þ 7 LED pattern indication Specifications þ Power supply 7 5 9VAC or 12VDC 250mA þ Load 24 240VAC þ 1 5A channel max þ Not suitable for inductive loads þ Dimensions 134x79mm 5 3 x3 1 modifica...

Page 2: ... 3 Aranciato Laranja Naranjado Oranssi Orange Orange Orange Orange Orange Orange Oranje 3 4 Giallo Amarelo Amarillo Keltainen Gul Gul Gul Gelb Yellow Jaune Geel 4 5 Verde Verde Verde Vihreä Grön Grøn Grønn Grün Green Vert Groen 5 6 Blu Azul Azul Sininen Blå Blå Blå Blau Blue Blue Blauw 6 7 Viola Violeta Morado Purppura Lila Violet Violet Violet Purple Violet Paars 7 8 Grigio Cinzento Gris Harmaa G...

Page 3: ...eads or to hold components in place Small blade and phillips screwdrivers A basic range is fine For some projects a basic multi meter is required or might be handy 1 2 Assembly Hints þ Make sure the skill level matches your experience to avoid disappointments þ Follow the instructions carefully Read and understand the entire step before you perform each operation þ Perform the assembly in the corr...

Page 4: ... 10K 1 0 3 B q R5 10K 1 0 3 B q R6 10K 1 0 3 B q R7 10K 1 0 3 B q R8 2K2 2 2 2 B q R9 2K2 2 2 2 B q R10 2K2 2 2 2 B q R11 2K2 2 2 2 B q R12 2K2 2 2 2 B q R13 2K2 2 2 2 B q R14 2K2 2 2 2 B q R15 100 1 0 1 B q R16 100 1 0 1 B q R17 100 1 0 1 B q R18 100 1 0 1 B q R19 100 1 0 1 B q R20 100 1 0 1 B q R21 100 1 0 1 B 3 DIODES Watch the polarity CATHODE D q D1 1N4148 q D2 1N4148 q D3 1N4148 q D4 1N4148 ...

Page 5: ...ETS Watch the posi tion of the notch q IC1 8P q IC2 14P q IC3 28P 5 PCB PINS q L1 L2 L3 L4 L5 L6 L7 N OSC SIG RST 2xJ1 6 CAPACITORS C q C1 10nF 103 q C2 100nF 104 q C3 100nF 104 q C4 100nF 104 7 ELECTROLYTIC CAPACITORS Watch the polarity C q C5 1µF q C6 1µF q C7 1000µF 8 TRANSISTORS q T1 BC547B q T2 BC547B q T3 BC547B q T4 BC547B q T5 BC547B q T6 BC547B q T7 BC547B ...

Page 6: ... CATHODE 23mm 0 9 q LD1 q LD2 q LD3 q LD4 q LD5 q LD6 q LD7 10 TRIM POTENTIOMETER q RV1 1M 11 VOLTAGE REGULATOR VR q VR1 7805 12 TRIACs 19mm 0 7 q TR1 T410 600T TIC216 or eq q TR2 T410 600T TIC216 or eq q TR3 T410 600T TIC216 or eq q TR4 T410 600T TIC216 or eq q TR5 T410 600T TIC216 or eq q TR6 T410 600T TIC216 or eq q TR7 T410 600T TIC216 or eq 13 PUSHBUTTON q SW1 14 SWITCH q SW2 ...

Page 7: ..._________________________________________________________________________________________________________________________________ 7 15 ROTARY SWITCH q SW3 16 ICs Watch the position of the notch q IC1 555 q IC2 4024 q IC3 VK5201 ...

Page 8: ...up the unit as shown in the diagram To use the internal speed adjustment connect OSC OUT with SIG IN by means of a wire jumper A external 5V CMOS clock signal e g generated by a beat detector can be connected between GND and SIG IN Cascading of two units Two units can be hooked up in cascade configuration to create a 14 channel lightshow Hook up both units as shown in the diagram The RE SET button...

Page 9: ..._________________________________________________________________________________________________________ 9 18 CONNECTION EXAMPLE FOR A SINGLE UNIT PRIM SEC RESET BANK SELECT PROGRAM SELECT 7 5 9VAC 0 25A FUSE 10A FUSE 50mA SLOW MAINS 1 5A CHANNEL MAX ...

Page 10: ..._______________________________________________________________________________________________________________________________________________________ 10 19 CASCADE OPERATION OF TWO UNITS ...

Page 11: ..._________________________________________________________________________________________________________________________________________________________ 11 20 DRILL PATTERN All values are in mm 1mm 0 04 ...

Page 12: ..._______________________________________________________________________________________________________________________________________________________ 12 21 PCB LAYOUT ...

Page 13: ...__________________________________________________________________________________________________________________________________________________________ 13 22 DIAGRAM ...

Reviews: