8
All wires of the output section must be at least 2.5mm².
Power supply wiring can be done with 0.5mm² wire.
Use fuse ratings as indicated on the connection examples.
Put an extra layer of solder on all tinned PCB tracks, to improve their current handling capabilities.
This unit is suitable for use with resistive loads, such as regular incandescent light bulbs.
The unit is not suitable for use with transformer operated lighting or fluorescent lighting.
17. ASSEMBLY, HOOK-UP AND USE
Assembly, Hook-up & Use
Attention : There is no transformer isolating this circuit from the mains.
Therefore, all parts of the PCB carry a potentially lethal voltage. The circuit
must be mounted in an adapted enclosure according to the applicable norms,
so that no live parts can be touched or present any other danger.