Velleman-Kit K2636 Assembly Manual Download Page 8

Test & connection 



ATTENTION:

 

  A PART OF THE CIRCUIT IS ALWAYS UNDER MAIN 

VOLTAGE. TAKE ALL POSSIBLE PRECAUTIONS, SO 
THAT  

 

NO-ONE CAN TOUCH ANY PART. FOR YOUR OWN  

  SECURITY AS FOR THE USERS' SECURITY. MOUNT 

THIS KIT PREFERABLY IN AN ISOLATING HOUSING. 
THE FUSE WILL MELT IN CASE OF AN OVERLOAD, RE-
PLACE IT BY EXACTLY THE SAME TYPE. 

 
 

 
 

 
 
 
 
 
 
 
 

 



Connect the load to the screw connector marked by "LOAD" see fig. 1. Consider the max. load (5,5A) 



Connect the mains voltage on the screw connector "MAINS". 

 



See whether you have mounted the right jumper (J1 or J2). 

 



The power voltage for the load is put on the connector. "VAC" (24 … 240VAC).  

 



See that this voltage and the "MAINS" voltage have the same frequency and that they are either in phase 
or in the opposite phase. Owing to the fact that the supply voltages of the load and the control circuit are 
completely separated, one can also connect low voltage loads. This makes this circuits fits for regulations 

M

110 - 240VAC

MAI

NS

LO

A

D

VA

C

L

N

L

N

Fig 1.0 

17. Test & connection 

Summary of Contents for K2636

Page 1: ...UNIVERSAL AC MOTOR CONTROL K2636 ILLUSTRATED ASSEMBLY MANUAL H2636IP 1 Easy speed control of AC collector motors...

Page 2: ...ac is protected against inductive voltage peaks from the motor The control circuit is powered by the mains but the load supply may be derived from a different AC source Both voltages should have the s...

Page 3: ...vers A basic range is fine For some projects a basic multi meter is required or might be handy 1 2 Assembly Hints Make sure the skill level matches your experience to avoid disappointments Follow the...

Page 4: ...DO NOT BLINDLY FOLLOW THE ORDER OF THE COMPONENTS ONTO THE TAPE ALWAYS CHECK THEIR VALUE ON THE PARTS LIST REMOVE THEM FROM THE TAPE ONE AT A TIME...

Page 5: ...tch the polarity D CATHODE R1 4K7 4 7 2 B R2 3K3 3 3 2 B R3 680 6 8 1 B R4 22K 2 2 3 B R5 22K 2 2 3 B R6 1K5 1 5 2 B R8 100K 1 0 4 B R12 1K 1 0 2 B R15 2K2 2 2 2 B 3 Resistors R Mount jumper according...

Page 6: ...C5 47nF C6 100nF 275VAC X2 C7 47nF 400V 8 Capacitors F1 250mA slow F2 5A slow 11 Fuse holders fuses F RV1 100K 12 Trim potentiometer RV L1 1mH 5A 1Khz 14 Coil TRAFO1 2 x 6V 2 x 0 3A Mount the 6V conn...

Page 7: ...7 Construction TR1 BT137F 600 Place the heatsink and the triac on the PCB Fix the two components with a M3 bolt and nut Now the triac may be soldered 16 Triac mm 3 BOLT M3 NUT LOCK WASHER 10mm M3 BOLT...

Page 8: ...r the max load 5 5A Connect the mains voltage on the screw connector MAINS See whether you have mounted the right jumper J1 or J2 The power voltage for the load is put on the connector VAC 24 240VAC S...

Page 9: ...er do not touch it Adjust RV2 so that the motor will have the lowest speed It is important for the motor to start at any time even where RV1 is put in its minimal position otherwise there might be lar...

Page 10: ...10 PCB PCB...

Page 11: ...11 Diagram Schematic diagram...

Page 12: ...odifications and typographical errors reserved Velleman nv Legen Heirweg 33 9890 Gavere Belgium H2636IP 1 2014 rev 5 5 4 1 0 3 2 9 3 1 1 4 1 4 VELLEMAN NV Legen Heirweg 33 B 9890 GAVERE Belgium Europe...

Reviews: