4Kw Air Fuel Heaters
9
3.3.2
The installation location of the fuel pump shall avoid high
temperature components. Do not use the fuel pump at a
temperature higher than 20 °C.
3.3.3
The height difference between the fuel level and the fuel pump
and the height difference between the fuel pump and the fuel
inlet of the heater will generate pressure in the fuel line. As a
result, these dimensions should meet the following
requirements: a ≤ 3m, b ≤ 0.5m, c≤2m. (b ≤ 0.15m is required
for a sealed fuel tank due to negative pressure)
Note:
1. Check the air vent of the fuel tank during installation.
2. After the fuel line is cut, ensure that the nozzle shape is
regular and will not affect the fuel supply.
3.3.4
Installation of fuel filter
The fuel filter must be installed before the inlet of the fuel
pump. Notice the fuel flow direction icon. It should point