5.1.1 HYDRAUL /C CON NE CT/ONS
The following is a summary of how to install the unit on a sea water circuit and condensate drain:
CORRECT SYSTEM INSTALLATION
CORRECT
STEADY UPWARDFLOW FRO INLET TD UNIT THEN DOWNWARD TO OUTLET, HOSES DOUBLE CLAMPED
SELF CONTAINED UIIIT
WATER UNE
SEA WA
l
ER
OU[LEl
fHRU HULL INLET
The minimum nominai dia meter of the connecting pipes should be 1 /2 ".
lf the pump is not self-priming, the through hull inlet must be oriented forw ard in order to have the boot
speed helping the priming. No damages con be caused by the water pressure into the filter or propeller.
WRONG SYSTEM INSTALLATION EXAMPLES:
INCORRECT
HDSES MUST l,O HAVE
l<
Nl
l<
S
,
LOOPS OR HIGH SPO
T
S WHERE AIR CAN BE TRAPPED
SELF CONT AINED UM
I
T
lnstruction manual
Pag.10of28
SCOOP TIPE
THRU HULL INLE T
SEA WATER
OUTLET