veito AERO S User Manual Download Page 4

Do not allow the supply cord to sit or hang in front of the heater while in use and 

keep it away from the body of the heater which will get hot during operation.

Keep the cable away from sharp edges during handling and installation.

Regularly inspect the power cord and plug for wear or damage and do not 

operate the heater with a damaged cord, plug or loose socket or after the heater 

malfunctions, has been dropped or damaged in any manner.

If the supply cord is damaged, it must be replaced by the manufacturer, it’s service 

agent or similarly qualified persons in order to avoid a hazard.

Do not locate the heater immediately above or below a fixed socket outlet or 

connection box. This is because the heat radiated from the appliance may damage 

the electricity outlet or plug.

Always unplug the heater when not in use.

The supply cable must be at the lower end of the heater if the heater is installed at 

an angle or vertically.

For installation use only the supplied accessories or original accessories approved 

by the manufacturer.

Do not place articles on or against this appliance.

A minimum safety distance of 1500 mm should always be left in front of the 

appliance.

This heater must be mounted at a minimum of 1800 mm above the floor.

INTRODUCTION

The AERO S carbon infrared heater is engineered as a robust indoor-outdoor heater. 

Every component in the AERO S heater is optimized for performance. That includes 

the veito carbon infrared tube producing mid-wave infrared heat. The AERO S 

heater has weatherproof design, which means you can use it for patios, terraces, 

smoking areas, conservatories, restaurants, hotels, garages, workshops, factories, 

warehouses and many more.

Model 

  AERO 

S

Voltage   

 

220-240V AC, 50/60 Hz

Power 

  2500W

Dimensions (W x H x D)  820 x 180 x 55 mm 

Weight 

  3 

kg

IP Rating 

 

IP44

4

Summary of Contents for AERO S

Page 1: ...veito User manual THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE AERO S...

Page 2: ...electric shock or injury to persons Do not install the heater directly near a bathtub shower or swimming pool Any switches or controls must not be within reach of a person in the bathtub shower or swi...

Page 3: ...liquids or vapours are stored Do not cover the heater Clothing or other flammable materials should not be hung from the heater or placed on or near the heater After unpacking make sure the appliance...

Page 4: ...heater when not in use The supply cable must be at the lower end of the heater if the heater is installed at an angle or vertically For installation use only the supplied accessories or original acces...

Page 5: ...the position or attempting to work on it If the heater has collected dust or dirt inside the unit or around the heating element have the unit cleaned by a qualified service agent Do not operate the he...

Page 6: ...inimum clearance of 500 mm from a ceiling and adjacent walls Mark and drill the mounting holes on the wall Attach the mounting bracket to the wall Bring the heater up to mounting bracket Insert M6 bol...

Page 7: ...Min 500mm Min 1800mm clearance to floor Max 45 angle 7 Min 500mm Max 90 angle...

Page 8: ...hin the European Community At the end of the electrical products useful life it should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or...