Summary of Contents for VS500

Page 1: ......

Page 2: ...3 1 Operating Instructions 9 3 2 Export Images 13 3 3 Focus 14 3 4 Projected ImageDescription 15 4 Cleaning and Maintenance 16 4 1 Cleaning 16 4 2 Maintenance 17 5 Battery 18 5 1 Built in Battery 18...

Page 3: ...to the physical characteristics of the patient the depth of the vein search is limited VeinSight vein finder is used to find the location of superficial veins which cannot be used as diagnostic infor...

Page 4: ...interference or high frequency interference in the vicinity of the deviceto ensure that the instrument is not in an environment of strong sources of electromagnetic interference such as interference...

Page 5: ...veins beneath the skin then projects the image of the veins on the skin surface directly above the veins Medical practitioners can refer to the projected image to find a vein of the right size and lo...

Page 6: ...finder has no waterproof protection Please prevent water ingress during use and storage No training is required to operate the VeinSight vein finder VeinSight vein finder requires no routine or preven...

Page 7: ...U Directive 93 42 EEC Materials can be recycled DC power Caution Manufacturer Date of manufacture Refer to the user manual IPX0 Waterproof grade Not waterproof Must not be directly discarded in the ho...

Page 8: ...ng interface of imaging unit Charging interface of charging cradle TYPE C port Temperature limit Humidity limit Atmospheric pressure limit Fragile handle with care No rain keep dry Upward direction No...

Page 9: ...VS500 VEIN FINDER USER GUIDE 7 2 4 Product Diagram Imaging Unit...

Page 10: ...by hand with ease and rapidly find and locate the veins of patients VS500 comprises the imaging unit and the charging cradle The imaging unit is used to project vein image Optional supports are avail...

Page 11: ...ling or setting is required before using the VeinSight vein finder 3 1 Operating Instructions Main Switch Switch to OFF to turn the device off Switch to ON and press Power button to turn the device on...

Page 12: ...tion color There are five colors to choose from including cyan green skin color red and blue The default color is cyan Long press this button to inverse the vein image The projection of the vein is di...

Page 13: ...on to enter the image gallery In this mode short press this button to browse the saved images long press the button again to exit this mode Short press these two buttons together to enter the venipunc...

Page 14: ...the device is in sleep mode waving a hand beneath the device can wake it up Note In the universal or fine detail mode Inverse and image size can be selected If one mode is selected the former mode wi...

Page 15: ...he device Operate according to the prompts of the software Note Please download the driver and the VS_Image_Viewer software on our website www veinsight com Note Please connect the device and the comp...

Page 16: ...be thicker or thinner than the actual width due to factors such as the distance between the VS500 to the skin the patient s physical features and even the different observation modes It is recommended...

Page 17: ...n below At the bottom area of the image information such as current mode battery status etc are shown in texts or graphics Current mode in use Distance sensing function on off indicator Distance indic...

Page 18: ...en air dry naturally or wipe it with a dust free cloth It is recommended that the body of the imaging unit be cleaned every two months Use a dust free cloth dipped in 70 alcohol to wipe it then air dr...

Page 19: ...terilize the device by heating or pressurizing Do not use other organic solvents or rough cleaning tools to wipe any parts of the device to avoid damage Note If there is abrasion or dirt on the lens w...

Page 20: ...ischarge the battery needs to be charged to recover Check the battery every 2 months to see if the charging and discharging work properly If there is any abnormality please contact the dealer or manuf...

Page 21: ...o power the charging cradle 2 Switch the main switch on the imaging unit to OFF 3 Mount the imaging unit onto the charging cradle 4 The indicator light is blue whenthe device is charging Note Make sur...

Page 22: ...ontinue charging When the indicator light turns green the battery is fully charged it is recommended to remove the imaging unit from the charging cradle Whentheindicatorlight flashes thebatterytempera...

Page 23: ...n condensing temperature 20 C to 50 C Please keep the device away from flammable and explosive gas source and handle with care to avoid impact or vibration when transporting 7 Technical Specifications...

Page 24: ...Adapter specifications Model FJ SW328U0502000N Rated Input 100 240V AC 50 60Hz 0 4A Rated Output 5V DC 2A Peak wavelength of infrared light About 850nm Valley wavelength of visible light About 530nm...

Page 25: ...device is five years from the manufacture date To properly dispose of used device after the expiry date please contact the dealer or the manufacturer and follow local regulations The proper disposal...

Page 26: ...s can be repaired or replaced free of charge The replaced parts will come with a Return of Material Authorization RMA number The newly repaired or replaced parts will enjoy a 90 day warranty period fr...

Page 27: ...acturer BLZ Technology Wuhan Co Ltd Address Room 2166 2176 Building E Cyberport Dongxing Road East Lake New Technology Development Zone 430074 Wuhan China European Representative MedPath GmbH Address...

Page 28: ...27 V1 0...