I-2.
ALARM SET – ALARM INPUT
Input alarm ways provide two different ways as NC (Normal Close) or NO (Normal Close)
The default setting is OFF
I-3.
ALARM SET – ALARM ACT
Alarm activates various surveillance modes with Preset number from1~64 and 100~200, Group tour up to 8,
Pattern up to 8. Move joystick to the right or left direction to select any preset number, group tour no. or
pattern no.
I-5.
ALARM SET – AUX ACT
You can select one of BLK(No Aux triggering)/AUX(triggering AUX1)/AUX2(triggering AUX2). The default
value is BLK.
I-5.
ALARM SET – SAVE
After set the alarm input ways and activation, to save the data, move joystick to the right direction when
the cursor is on SAVE. After saving the data, the cursor moves to Alarm NO.2 automatically to prepare the
next alarm.
I-6.
ALARM SET –EXIT
To escape this page, move joystick to the right direction
* Before activate Alarm, user must set ALARM ENABLE at Dome Setup – ALARM – ENABLE (Refer
to page 16)
J. SECTOR SET
Up to 8 programmable sectors are available with 16 characters.
This feature is useful to memory the certain location such as parking zone or so on.