7
3 Mounting
Rinsing connection • for VEGAPULS WL 61, 61, 64, 67 and 69
49552-EN-200717
3 Mounting
3.1 Mounting preparations
Required tools:
•
Torx wrench, size T25
3.2 Mounting steps compression flange, adapter
flange ASME 3"
Proceed as follows:
1. Apply flat seal (provided by the customer) to the process flange
2. Place rinsing connection (with the smooth lower surface) onto the
process flange
1
2
3
4
5
6
Fig. 4: Mounting of the rinsing connection with compression flange and adapter
flange ASME 3"
1 Compression or adapter flange ASME 3"
2 O-ring seal
3 Rinsing connection
4 Reflux valve
5 Process seal (provided by customer)
6 Process flange
3. Insert O-ring seal into the groove on the upper side of the rinsing
connection
4. Screw reflux valve (optional) into the rinsing connection
5. Set sensor with compression or adapter flange ASME 3" to rins-
ing connection
6. Tighten flange screws evenly, e.g. crosswise in two or three
passes. Tightening torque, see chapter "
Technical data
".
3.3 Mounting stepps adapter flanges from 4"/
DN 100
Proceed as follows:
1. Loosen mounting screws of the adapter ring, detach adapter ring
Tool