VEGAPULS 56K
29
3.3 Approvals
When using radar sensors in Ex and StEx-
areas or on ships the instruments must be
suitable and approved for these explosion
zones and applications. The suitability is
checked by the approval authorities and is
certified in approval documents.
VEGAPULS 56 radar sensors are approved for
Ex-zone 1 and zone 0.
Please note the attached approval documents
(yellow binder) when you want to use a sensor
in Ex-area.
Test and approval authorities
VEGAPULS radar sensors are tested and
approved by the following monitoring, test and
approval authorities:
-
PTB
(Physikalisch Technische Bundesanstalt -
Physical Technical Approval Authority)
-
FM
(Factory Mutual Research)
-
ABS
(American Bureau of Shipping)
-
LRS
(Lloyds Register of Shipping)
-
GL
(German Lloyd)
-
CSA
(Canadian Standards Association)
Technical data
Ex-area zone 0/zone 1
Series 50 sensors require for use in Ex-areas
special safety barriers or separators providing
intrinsically safe (ia) circuits.
Following a choice of instruments with which
VEGAPULS 56 sensors work reliably. In
conjunction with safety barriers the resistor of
the signal line and the separator resistor
(separator voltage loss) must not exceed the
max. load (see load diagram in chapter
"3.1 Data“).
Ex-area zone 0/zone 1 without Exd-connec-
tion housing:
Separators and signal conditioning instru-
ments:
• VEGADIS 371 Ex
• VEGAMET 614 Ex
• A puissance 3 PROFSI 37-24070A
• Apparatebau Hundsbach
AH MS271-B41EEC010
Separator:
• Stahl 9303/15/22/11
• CEAG GHG 124 3111 C1206
• VEGATRENN 149 Ex
Separator/Safety barrier:
• Stahl 9001/01/208/110/10
• CEAG GHG 11 1 9140 V0728
• Type 9130 (VEGA)
• Stahl 9001/51/280/110/14
• MTL 787 St
• CEAG CS3/420-106