14
4 Mounting
VEGAMIP R62 • Receiving unit
41911-EN-200522
Medium type
Medium
Min. medium thickness
Foodstuffs and wood
Flour
> 100 mm
Cereals, corn, rice
> 100 mm
Wood chips (dry)
> 500 mm
Wood chips (moist)
> 100 mm
Mineral products / Ore
Stones (e.g. limestone)
> 100 mm
Cement, clinker
> 100 mm
Glass (crushed)
> 100 mm
Coal
> 50 mm
Bauxite
> 100 mm
Ore
> 100 mm
If VEGAMIP 62 is mounted in the filling stream, unwanted false meas
-
urement signals can be generated. For this reason, mount VEGAMIP
62 at a position in the vessel where no disturbances, e.g. from filling
openings, agitators, etc., can occur.
Microwaves can penetrate non-conductive materials. Hence, it is pos-
sible to measure through the wall of non-conductive vessels.
Fig. 7: Bulk solids vessel of plastic
In metal vessels, you have to mount VEGAMIP 62 on flanges or
threaded sockets. It is also possible to measure through a window. In
general, all products such as glass, ceramic and plastic are suitable
as window material.
Max. thickness of the window material:
Type of material
Window material
Max. thickness
Plastics
PTFE, PS
< 5000 mm
PP, PE, HDPE, POM
< 1000 mm
PA, PVC, PVDF
< 500 mm
Rubber
< 50 mm
Inflowing medium
Non-metallic vessels
Metal vessels