background image

N

umber of bytes

S

ign

I

denti

er

1

?

B

egin

1

3

001

030

or

1

30

S

eparator

1

L

or

I

Q

uantity

1

3

001

030

or

1

30

E

nd identi

cation

1

CR

l

I

denti

er

:

"

?

"

(

1

character

)

l

S

tart

:

N

o

.

of the requested

PC

/

DCS

output

(

1

3

characters

)

l

S

eparator

:

"

L

"

or

"

I

"

(

1

sign

)

l

Q

uantity

:

N

umber of requested

PC

/

DCS

outputs

(

1

3

signs

)

l

E

nd identi

cation

:

C

arriage

R

eturn

CR

(

1

sign

)

T

otal length of the telegram

:

5

9

characters

"

Q

uantity

"

-

times repetition of the following telegram

N

umber of bytes

S

ign

T

1

1

=

DCS

no

.

3

001

030

T

2

1

#

V

alue

7

-

000673

T

3

1

#

U

nit

0

n

xxx

E

nd identi

cation

1

CR

l

T

1

:

"="

(

1

sign

)

l

DCS

no

.:

N

o

.

of the

PC

/

DCS

output as

3

-

digit decimal

number

l

T

2

:

"

#

"

(

1

character

)

l

V

alue

:

N

umerical value of the

PC

/

DCS

output or in case of

faulty measured value the text

"

FAULT

"

F

ormatting of the value

:

S

ign

M

eaning

1

"

-

"

:

M

inus with negative numbers

" "

:

S

pace with positive numbers

2

7

6

-

digit number after the decimal point

E

nquiry of the control system

A

nswer from the signal con

-

ditioning instrument

M

odbus

-

TCP

,

VEGA ASCII

protocol

-

VEGAMET

624

/

625

,

VEGASCAN

693

,

PLICSRADIO

27

VEGA ASCII

protocol

30768

-

EN

-

070730

Summary of Contents for VEGAMET 624

Page 1: ...Supplementary instructions manual Modbus TCP VEGA ASCII protocol VEGAMET 624 625 VEGASCAN 693 PLICSRADIO C62 Signal conditioning instruments and communication in out...

Page 2: ...11 2 3 Version enquiry with command VERSION 12 2 4 Help with command HELP 12 2 5 Delete the settings with the command CLEARSTORE 13 2 6 Measured value enquiry with command 13 2 7 Measured value enqui...

Page 3: ...uiry of the relay values l Function code 02 Read Input Status enquiry of the relay values l Function code 03 Read Holding Registers enquiry of the PC DCS values l Function code 04 Read Input Registers...

Page 4: ...DCS output 3 Measured value 30006 PC DCS output 3 Status 30007 PC DCS output 4 Measured value 30008 PC DCS output 4 Status 30009 PC DCS output 5 Measured value 30010 PC DCS output 5 Status 30011 PC D...

Page 5: ...e Low Byte High Byte Low Byte The status describes the condition of the associated measured value The content of the measured value is only valid if the corresponding status has the value zero If ther...

Page 6: ...sure ment loops 4 6 the value 0 switch open and 100 switch closed are transmitted as measured values the units are deleted The switching conditions of the relay are transferred as bit information The...

Page 7: ...ured value 31011 PC DCS output 3 Status 31013 PC DCS output 4 Measured value 31015 PC DCS output 4 Status 31017 PC DCS output 5 Measured value 31019 PC DCS output 5 Status 31021 PC DCS output 6 Measur...

Page 8: ...easure ment loops 4 6 the value 0 switch open and 100 switch closed are transmitted as measured values the units are deleted 984 Floating point Intel single precision real First register contains bits...

Page 9: ...s l 0 Switching status O l 1 Switching status On The following equivalencies apply to the fail safe relay l 0 Failure message O relay switching condition On l 1 Failure message O relay switching condi...

Page 10: ...default l Coding system 8 Bits ASCII l Baud rate 9600 Bits sec l Data bits 8 l Parity none l Stop bits 1 For direct connection between signal conditioning instrument and PC or DCS the RS232 modem conn...

Page 11: ...Enquiry of the protocol version help Indication of the command formats clearstore Settings of the option Store will be deleted in the EEPROM memory Measured value enquiry with three places in front of...

Page 12: ...ved up to the STORE option and executed after a restart only available with RS232 interface SUM A check sum is transmitted for each line which is sent Information For commands and options no di erence...

Page 13: ...gn Identi er 1 Begin 1 3 001 030 or 1 30 End identi cation 1 CR l Identi er 1 character l Start No of the requested PC DCS output 1 3 signs l End identi cation Carriage Return CR 1 sign Total length o...

Page 14: ...d value is transmitted with three positions in front of the decimal point and one position after the decimal point without unit Number of bytes Sign Identi er 1 End identi cation 1 CR l Identi er 1 ch...

Page 15: ...int l T3 1 character l End identi cation Carriage Return CR 1 sign Total length of the telegram N 12 13 signs Note The sign is a separator not the unit Enquiry Answer 001 067 3 002 824 6 003 067 3 004...

Page 16: ...r of bytes Sign T1 1 DCS no 3 001 030 T2 1 Value 5 6 067 3 T3 1 End identi cation 1 CR l T1 1 sign l DCS no No of the PC DCS output as 3 digit decimal number l T2 1 character l Value Numerical value o...

Page 17: ...ithout unit Number of bytes Sign Identi er 1 Begin 1 3 001 030 or 1 30 Separator 1 End 1 3 001 030 or 1 30 End identi cation 1 CR l Identi er 1 character l Start Start no of the requested PC DCS outpu...

Page 18: ...er 5 Decimal point 6 1 digit number after the decimal point l T3 1 character l End identi cation Carriage Return CR 1 sign Total length of the telegram End Start 1 12 13 Note The sign is a separator n...

Page 19: ...l DCS no No of the PC DCS output as 3 digit decimal number l T2 1 character l Value Numerical value of the PC DCS output or in case of faulty measured value the text FAULT Formatting of the value Sig...

Page 20: ...the telegram 2 characters N times repetition of the following telegram N total number of assigned PC DCS outputs Number of bytes Sign T1 1 DCS no 3 001 030 T2 1 Value 7 000673 T3 1 End identi cation...

Page 21: ...alues is delivered The measured value is transmitted with six decimal places without decimal point and unit Number of bytes Sign Identi er 1 Begin 1 3 001 030 or 1 30 Separator 1 L or I Quantity 1 3 0...

Page 22: ...2 7 6 digit number after the decimal point l T3 1 character l End identi cation Carriage Return CR 1 sign Total length of the telegram Quantity 14 signs Note The sign is a separator not the unit Enqui...

Page 23: ...ng telegram Number of bytes Sign T1 1 DCS no 3 001 030 T2 1 Value 5 6 000673 T3 1 End identi cation 1 CR l T1 1 sign l DCS no No of the PC DCS output as 3 digit decimal number l T2 1 character l Value...

Page 24: ...ix decimal places with decimal point and unit Number of bytes Sign Identi er 1 Begin 1 3 001 030 or 1 30 End identi cation 1 CR l Identi er 1 character l Start No of the requested PC DCS output 1 3 ch...

Page 25: ...2 8 1 Block enquiry As answer to the block enquiry all assigned PC DCS values in the instrument are transmitted The measured value is trans mitted with six decimal places without decimal point and wi...

Page 26: ...ter the decimal point l T3 1 character l Unit Unit as text 0 n unit l End identi cation Carriage Return CR 1 sign Total length of the telegram N 14 characters Unit character Enquiry Answer 001 000673...

Page 27: ...g telegram Number of bytes Sign T1 1 DCS no 3 001 030 T2 1 Value 7 000673 T3 1 Unit 0 n xxx End identi cation 1 CR l T1 1 sign l DCS no No of the PC DCS output as 3 digit decimal number l T2 1 charact...

Page 28: ...tes Sign Identi er 1 Begin 1 3 001 030 or 1 30 Separator 1 End 1 3 001 030 or 1 30 End identi cation 1 CR l Identi er 1 character l Start Start no of the requested PC DCS output 1 3 characters l Separ...

Page 29: ...decimal point l T3 1 character l Unit Unit as text 0 n unit l End identi cation Carriage Return CR 1 sign Total length of the telegram End Start 1 14 signs Unit sign Enquiry 001 003 Answer 001 000673...

Page 30: ...umber l T2 1 character l Value Numerical value of the PC DCS output or with interferred measured value the error code Exxx Formatting of the value Sign Meaning 1 Minus with negative numbers Space with...

Page 31: ...f assigned PC DCS outputs Number of bytes Sign T1 1 DCS no 3 001 030 T2 1 Value 11 824 6 T3 1 Unit 0 n xxx End identi cation 1 CR l T1 1 sign l DCS no No of the PC DCS output as 3 digit decimal number...

Page 32: ...er 1 Begin 1 3 001 030 or 1 30 Separator 1 L or I Quantity 1 3 001 030 or 1 30 End identi cation 1 CR l Identi er 1 character l Start No of the requested PC DCS output 1 3 characters l Separator L or...

Page 33: ...Unit as text 0 n unit l End identi cation Carriage Return CR 1 sign Total length of the telegram Quantity 14 signs Unit sign Enquiry 001L003 Answer 001 67 3 kg 002 824 3 003 67 3 m 2 9 1 Block enquiry...

Page 34: ...l T1 1 sign l DCS no No of the PC DCS output as 3 digit decimal number l T2 1 character l Value Numerical value of the PC DCS output or in case of faulty measured value the error code Exxx Formatting...

Page 35: ...al places l ss seconds with 2 decimal places Note The character string is terminated with CR Enquiry 001 time Answer 2005 04 07 09 00 50 001 24 44 2 11 Option REPEAT x By attaching the attribute REPEA...

Page 36: ...09 02 19 001 27 55 002 28 44 2005 04 07 09 02 29 001 27 55 002 28 44 Voltage interruption If the instrument is switched o now and then switched on again the instrument sends automatically the answer...

Page 37: ...Modbus TCP VEGA ASCII protocol VEGAMET 624 625 VEGASCAN 693 PLICSRADIO 37 VEGA ASCII protocol 30768 EN 070730...

Page 38: ...38 Modbus TCP VEGA ASCII protocol VEGAMET 624 625 VEGASCAN 693 PLICSRADIO VEGA ASCII protocol 30768 EN 070730...

Page 39: ...Modbus TCP VEGA ASCII protocol VEGAMET 624 625 VEGASCAN 693 PLICSRADIO 39 VEGA ASCII protocol 30768 EN 070730...

Page 40: ...om www vega com ISO 9001 All statements concerning scope of delivery application practical use and operating conditions of the sensors and processing systems correspond to the information avail able a...

Reviews: