Set-up

In the window “Instrument data parameter
adjustment“, you can click on the functions
relevant for your measurement loop (e.g.
when you have a measurement loop with
VBUS-sensor, then only the button 

Sensor

optimisation

 is active). Move through the

functions 

Adjustment 

to 

Additional Func-

tion

, and then return to the VVO-main win-

dow with 

Quit

.

Summary of Contents for VEGALOG 571

Page 1: ...Level and Pressure in out Operating Instructions VEGALOG 571 on on on PC on VEGALOG 1 2 3 4 5 6 7 8 9 10 571 CPU VEGALOG 571 EA VEGALOG 571 EV VEGALOG 571 AR...

Page 2: ...Mounting in carrier 25 2 3 Selection of the plug position 26 2 4 Coding 26 2 5 Co ordination 27 3 Electrical connection 3 1 General connection instructions 28 3 2 Coupling of the carriers 29 3 3 Inter...

Page 3: ...s not take responsibility Note Ex area Please note the approval documents attached yellow binder and especially the included safety data sheet 4 Set up 4 1 Indicating and adjustment elements 38 4 2 Ad...

Page 4: ...signal 0 4 20 mA as voltage signal 0 2 10 V as relay transistor contact as digital signal RS 232 interface Adjustment surface The adjustment of VEGALOG 571 is made by a PC connected via an RS 232 cabl...

Page 5: ...ement loop Product description DCS components DCS telegram to VEGA COM 557 Functional components Parameter for meas loop 1 meas loop 2 meas loop 255 Input components Analogue inputs current inputs 0 2...

Page 6: ...on the number of measurement loops CPU cards in different performances of up to 15 30 60 or 255 measurement loops are available The CPU reads cyclically measured values from the peripheral cards with...

Page 7: ...n of different VBUS sensors via common two wire line This means that a transmission is avail able which is not only optimally adapted to the conditions of the level measurement but also has increased...

Page 8: ...rovides 10 relay outputs with floating spdt The following instruments can be connected acoustic or optic signallers magnet valves contactors etc The AR card is suitable for the output of level individ...

Page 9: ...d can be used exclu sively to provide the data of VEGALOG to the visualisation software Visual VEGA VV For this purpose the communication card is also available without interface converter function Ad...

Page 10: ...nologies Electrical protective measures Protection not mounted IP 00 in carrier BGT LOG 571 front side completely equipped IP 40 upper and lower side IP 20 wiring side IP 00 Protection class I in carr...

Page 11: ...ectrodes hydrostatic pressure transmitters vibrating level switches conductive electrodes process and differential pressure transmitters Further connection possibilities external current sources 0 20...

Page 12: ...asonic sensors radar sensors Sensor supply voltage 3 x 24 V DC 1 A short circuit proof for 5 sensors each Connection line 2 wire screening recommended Line length max 1000 m 1 Resistance per conductor...

Page 13: ...V Common potential between current outputs GND Indicating elements LED in front facia green on mains voltage on red fault signal AD card DISBUS output Number 1 output Function digital transmission of...

Page 14: ...cc to VDE 0106 from relays to the power supply and part 1 LOGBUS connection reference voltage 250 V isolation resistance 2 3 kV Galvanic isolation between among relays reference voltage 250 V isolatio...

Page 15: ...ecommended Line length max 1000 m Meas data input LOGBUS Data transmission LOGBUS digital data transmission Connection line connection via BUS plug PC interface Interface standard RS 232 C Line length...

Page 16: ...gulations of EMVG 89 336 EWG and NSR 73 23 EWG The conformity has been judged acc to the following standards VEGASTAB 593 594 VEGASTAB 593 60 EMVG Emission EN 50 081 1 EN 50 081 1 Susceptibility EN 50...

Page 17: ...0 Power supply Input voltage Unom 230 V AC 196 264 V 50 60 Hz 110 V AC 94 127 V 50 60 Hz 120 V AC 102 138 V 50 60 Hz Input current effective 230 V max 0 5 A 110 V 120 V max 1 0 A Fuse 5 x 20 mm in the...

Page 18: ...other module cards of VEGALOG CPU card 162 100 5 5 128 4 25 4 5 TE 9 on 571 CPU PC VEGALOG Multipoint connector 100 x 160 x 1 5 European size Multiple plug LOGBUS plug Power supply card VEGASTAB Produ...

Page 19: ...easurement loop Click in the main window of VVO on Configuration point to Measurement loop and click on New Then confirm the adjustment a new application with OK In the next window Create new measure...

Page 20: ...eal value correction Zero point correction Density correction Parameter Level Application Gauge measurement Sensor Hydrostatic pressure transmitters Ultrasonic sensors Radar sensors Mode Standard Opti...

Page 21: ...Level Application Connection of a switching contact Sensor External switching contact Mode Standard Option none Parameter Switching condition Application Connection of a 4 20 mA instrument Sensor 4 2...

Page 22: ...o point correction Real value correction Density correction Parameter Level Density Not corrected level Application Level difference Sensor Ultrasonic sensors Radar sensors Mode Difference Option Real...

Page 23: ...y measurement Sensor Hydrostatic pressure transmitters Process pressure transmitters Mode Standard Option Zero point correction Parameter Density Level Not corrected level Application Arithmetic measu...

Page 24: ...value e g 40 Real value correction Density correction incorrect course of measured values incorrect course of measured values higher density measured value too high lower density measured value too lo...

Page 25: ...arrier are mounted one above the other when more than 2 5 W TE are consumed in the carrier when there is no air circulation in the range of the carrier Mounting 2 2 Mounting in carrier The carrier BGT...

Page 26: ...stem avoids inter changing among the different module cards in the carrier It consists of two coded pins in the multipoint connector in the carrier two holes in the multiple plug of the appro priate c...

Page 27: ...r supply used Mounting 1 2 3 4 5 6 7 8 910111213141516 17181920212223242526272829303132 Module no Card max power re TE no quirement W 1 5 2 10 3 15 4 20 5 25 6 30 7 35 8 40 9 45 10 50 11 55 12 60 13 6...

Page 28: ...e neces sary wire cross sections must be main tained if overvoltages are expected we recom mend a sensors electronic with integral overvoltage protection or the installation of VEGA overvoltage arrest...

Page 29: ...le hook switch for termination resistor slide switch Configuration with one rack Hook switch closed Slide switch position M Configuration with two racks Rack 1 Hook switch closed Slide switch position...

Page 30: ...nic radar sensors or pressure transmitters max 5 ultrasonic radar sensors or pressure transmitters max 5 ultrasonic radar sensors or pressure transmitters Note All 10 sensor inputs z14 z32 are connect...

Page 31: ...6 8 4 Supply voltage Supply voltage Supply voltage Note The connections z14 z32 are connected broken line Relay output 1 d14 b14 z14 2 d16 b16 z16 3 d18 b18 z18 4 d20 b20 z20 5 d22 b22 z22 6 d24 b24 z...

Page 32: ...ne common power supply unit with additional voltage the connected sensors are galvanically connected among each other Each branch with max five sensors is short circuit proof The integral current limi...

Page 33: ...5 10 15 20 25 1000 900 800 700 600 500 400 300 200 100 0 0 5 10 15 20 25 For graphic determination the following pro cedure is recommended consider each branch separately determine the power consumpti...

Page 34: ...ts an own line pair not rec ommended VEGALOG 571 with EV card VEGALOG 571 with EV card VEGALOG 571 with EV card Line length up to 1000 m Line length up to 1000 m Line length max 100 m per sensor 3 7 S...

Page 35: ...s well as the used sepa rating facility must only be mounted out side the Ex area a separating wall must be added between connection parts of intrinsically and not intrinsically safe circuits so that...

Page 36: ...V Ex EV card Ultrasonic or radar on VEGALOG 571 EV 11 12 1 2 ia Trennbarriere Typ 145 Ausgang Zone 0 Eingang Ex area Not Ex area Pressure transmitter EA card Safety barrier type 145 The sum of the inn...

Page 37: ...0 1nF searched Determination of the line data Lint 1 mH 0 065 mH 0 13 mH 0 805 mH Cint 580 nF 0 nF 1nF 579 nF Calculation of the line length 0 805 mH l m 1 238 m 0 65 H 579 nF l m 4 825 m 120 pF Consi...

Page 38: ...fication of the min max adjustment the integration time etc The already configured measuring system is now optimally adapted to the appli cation Configuration of VEGALOG The plug position for the indi...

Page 39: ...X In this window you can modify sensor desig nations Sensor TAG and enter serial num bers manually Click on the appropriate sensor and then click on Configure Your VEGALOG is now shown in your con fig...

Page 40: ...s of the CPU e g a total power loss of the CPU With Quit you return to the main window of VVO Create new measurement loops A number of applications can be created in VEGALOG with the adjustment softwa...

Page 41: ...rd 4 ana logue inputs input no 2 If you now click on Info you see to which card terminals the sensor must be connected With OK you return to the window Create new measure ment loop Sensor configuratio...

Page 42: ...is possible to undo this co ordination When you have finished the current outputs click on OK Proceed in the same way for the other outputs It is also possible to adjust the mode standard reset of ala...

Page 43: ...an click on the functions relevant for your measurement loop e g when you have a measurement loop with VBUS sensor then only the button Sensor optimisation is active Move through the functions Adjustm...

Page 44: ...rief communication problems up to 1 sec on the LOGBUS do not effect the status indi cation Hardware failure Permanent lighting of the red LED means a hardware failure 5 3 Failure removal In order to d...

Page 45: ...then possible Furthermore levels and fault signals are displayed 6 2 Communication By means of the interface converter VEGA COM 557 measured data and status infor mation of the CPU and the peripheral...

Page 46: ...lly via VEGACON NECT VEGASON VEGAPULS via VEGACON NECT to the signal line or on the sensor Supplement 6 3 Components for configuration LOGBUS PLC DCS PC DISBUS 2 Visual VEGA Visualisation software for...

Page 47: ...EGACOM 557 5 VEGACONNECT 2 Connection cable interface converter be tween VEGA instruments pressure transmit ters VEGASON VEGAPULS VEGAMET and a PC in conjunction with the adjustment software VEGA Visu...

Page 48: ...lding 505 Yardley PA 19067 7706 Tel 215 321 6012 Fax 215 321 6067 Tech Support Toll Free 866 DrLevel or 888 NIVELCO Email info DrLevel com or info hitechtech com Web Site www DrLevel com or www hitech...

Reviews: