![Vega VEGACAP 60 Series Operating Instructions Manual Download Page 7](http://html1.mh-extra.com/html/vega/vegacap-60-series/vegacap-60-series_operating-instructions-manual_3836009007.webp)
8
C
ompare the settings of the two electronics modules
.
S
et the
adjustment elements of the new electronics module to the same
setting of the old one
.
I
nformation
:
M
ake sure that the housing is not rotated during the electronics
exchange
.
O
therwise the plug may be in a di
ff
erent position later
.
9
I
nsert the electronics module carefully
.
M
ake sure that the plug is
in the correct position
.
10
S
crew in the two holding screws and tighten them
11
I
nsert the wire ends into the open terminals according to the wiring
plan
12
P
ress down the opening levers of the terminals
,
you will hear the
terminal spring closing
13
C
heck the hold of the wires in the terminals by lightly pulling on
them
14
C
heck cable gland on tightness
.
T
he seal ring must completely
encircle the cable
.
15
M
ount the probe into the vessel
.
M
ake sure that the probe is
uncovered
.
2
1
F
ig
.
2
:
C
ompensation key
1
M
easuring range selection switch
(
compensation key
)
2
C
ontrol lamp
16
P
ush the measuring range selection switch
(
1
)
as long as the
control lamp
(
2
)
fl
ashes green
.
17
H
ence the probe is compensated to the modi
fi
ed length
.
18
C
arry out the adjustment again
.
S
ee chapter
"
S
et
-
up
,
adjustment
elements
"
.
19
S
crew the housing cover back on
T
he electronics exchange is now
fi
nished
.
A
s a rule
,
an exchange of electronics must be documented internally
when
E
x applications are involved
.
E
lectronics module
•
VEGACAP
series
60
7
4
M
ounting
30174
-
EN
-
120124