Vega VEGACAP 60 Series Operating Instructions Manual Download Page 7

8

C

ompare the settings of the two electronics modules

.

S

et the

adjustment elements of the new electronics module to the same
setting of the old one

.

I

nformation

:

M

ake sure that the housing is not rotated during the electronics

exchange

.

O

therwise the plug may be in a di

erent position later

.

9

I

nsert the electronics module carefully

.

M

ake sure that the plug is

in the correct position

.

10

S

crew in the two holding screws and tighten them

11

I

nsert the wire ends into the open terminals according to the wiring

plan

12

P

ress down the opening levers of the terminals

,

you will hear the

terminal spring closing

13

C

heck the hold of the wires in the terminals by lightly pulling on

them

14

C

heck cable gland on tightness

.

T

he seal ring must completely

encircle the cable

.

15

M

ount the probe into the vessel

.

M

ake sure that the probe is

uncovered

.

2

1

F

ig

.

2

:

C

ompensation key

1

M

easuring range selection switch

(

compensation key

)

2

C

ontrol lamp

16

P

ush the measuring range selection switch

(

1

)

as long as the

control lamp

(

2

)

ashes green

.

17

H

ence the probe is compensated to the modi

ed length

.

18

C

arry out the adjustment again

.

S

ee chapter

"

S

et

-

up

,

adjustment

elements

"

.

19

S

crew the housing cover back on

T

he electronics exchange is now

nished

.

A

s a rule

,

an exchange of electronics must be documented internally

when

E

x applications are involved

.

E

lectronics module

VEGACAP

series

60

7

4

M

ounting

30174

-

EN

-

120124

Summary of Contents for VEGACAP 60 Series

Page 1: ...Operating Instructions Electronics module VEGACAP series 60 Document ID 30174 Capacitive...

Page 2: ...ct description 3 1 Structure 5 3 2 Principle of operation 5 3 3 Packaging transport and storage 5 4 Mounting 4 1 Instructions for installation 6 4 2 Mounting preparations 6 4 3 Mounting steps 6 5 Setu...

Page 3: ...es helpful additional information Caution If this warning is ignored faults or malfunctions can result Warning If this warning is ignored injury to persons and or serious damage to the instrument can...

Page 4: ...tallation and operation in Ex areas These safety instructions are part of the operating instructions manual and come with the Ex approved instruments 2 4 Environmental instructions Protection of the e...

Page 5: ...tes on the transport packaging Nonobservance of these instructions can cause damage to the device The delivery must be checked for completeness and possible transit damage immediately at receipt Ascer...

Page 6: ...steps To exchange the electronics module proceed as follows 1 Switch o power supply 2 Unscrew the housing cover 3 Lift the opening levers of the terminals with a screwdriver 4 Pull the connection cab...

Page 7: ...closing 13 Check the hold of the wires in the terminals by lightly pulling on them 14 Check cable gland on tightness The seal ring must completely encircle the cable 15 Mount the probe into the vesse...

Page 8: ...mmediately ready for operation In general all oscillators of series CP60 can be interchanged If you want to use an electronics module with a di erent signal output you can download the corresponding o...

Page 9: ...ithout having to call back for needed information l Print and ll out one form per instrument l Clean the instrument and pack it damage proof l Attach the completed form and if need be also a safety da...

Page 10: ...tive 2002 96 EG and the respective national laws in Germany e g ElektroG Pass the instrument directly on to a specialised recycling company and do not use the municipal collecting points These may be...

Page 11: ...8 Supplement 8 1 Technical data Technical data are stated in the operating instructions manual of the respective sensor Electronics module VEGACAP series 60 11 8 Supplement 30174 EN 120124...

Page 12: ...vega com Printing date ISO 9001 All statements concerning scope of delivery application practical use and operating conditions of the sensors and processing systems correspond to the information avail...

Reviews: