VEGABAR 14
17
22442-EN-021023
Connect power supply
7 Snap the plug insert into the plug housing and
insert the sensor seal
8 Plug the plug connector onto VEGABAR and
tighten the screw.
The electrical connection is finished.
5.3 Wiring plans
Angle plug connector acc.
to DIN 43560
2
1
3
-
+
Power supply
12 … 30 V DC
Cable outlet
+
+
+
–
–
–
R
L
Power supply
12 … 30 V DC
Cable screen
Fig. 8:
Wiring plan for angle plug connector acc. to DIN 43560
Fig. 9:
Wiring plan for direct cable outlet