background image

8

.

2

L

icence agreements

8

.

2

.

4

§

1

S

upplement to existing regulations

§

1

.

1

T

ransfer of perils with electronic communication media

T

he following paragraphs supplement the general sales

,

delivery and

payment conditions of

VEGA

with the speci

c points for software

products

.

E

xisting points remain una

ected by additions

.

T

he general

sales

,

delivery and payment conditions are available in the

I

nternet

under www

.

vega

.

com

/

agb

.

§

1

.

2

T

ransfer of perils with electronic communication media

W

hen software is transferred via electronics communication media

(

for

example and in particular via the

I

nternet

)

the transfer of perils to the

buyer takes place when the software leaves

VEGA

'

s sphere

.

§

1

.

3

L

iability for faulty goods

a

)

VEGA

will replace faulty data carriers with faultless ones

.

b

)

T

he software is considered faulty if provable

,

reproducible errors

occur which make the software deviate considerably from the
descriptions in the accompanying documentation

.

c

)

I

mprovements to the software are normally provided via update

/

upgrade

.

d

)

VEGA

will decide

,

within the framework of the guarantee

,

where

errors will be diagnosed and corrected

(

at

VEGA

headquarters or

at the customer

'

s site

).

Y

ou will provide the documentation and

information necessary for correction of errors

.

I

f the correction is

carried out at your premises you will provide the required hardware
and software free of charge as well as the necessary operating
conditions with appropriate operating personnel

,

so that the work

can be performed quickly

.

e

)

VEGA

can demand reimbursement for test expenditures if you

reported an error which ultimately could not be demonstrated or
otherwise ascertained

.

f

)

Y

ou have to take all adequate measures to avoid or limit

consequences of loss by software errors

,

in particular inform

VEGA

immediately on this error and make sure that the entered

data to be processed are saved

.

g

)

T

he warranty period for software is

12

months

.

T

his period begins

at the time of transfer of perils

.

W

hen copies are made under the

provisions of a multiple licence

,

the warranty period of the original

software applies

.

PC

operation

VEGABAR

12

13

8

S

upplement

35584

-

EN

-

090702

Summary of Contents for VEGABAR 12

Page 1: ...Operating Instructions PC operation VEGABAR 12 Document ID 35584 Indication and adjustment...

Page 2: ...3 2 Principle of operation 5 3 3 Storage and transport 5 4 Installation 4 1 System requirements 6 4 2 Install software 6 5 Operation 5 1 Connecting the PC 7 5 2 Start PC operation 7 6 Maintenance and...

Page 3: ...sed Information tip note This symbol indicates helpful additional information Caution If this warning is ignored faults or malfunctions can result Warning If this warning is ignored injury to persons...

Page 4: ...n speci c hazards e g vessel over ll or damage to system components through incorrect mounting or adjustment 2 4 General safety instructions Installation and use of the software are carried out at you...

Page 5: ...rent data from device Serial number Measuring range Adjustment Pressure type Software version l Save min max adjustment data in device 3 3 Storage and transport The packaging consists of easily separa...

Page 6: ...or higher Microsoft compatible mouse RS232 interface 4 2 Install software 1 Before installation all running programs should be exited 2 Insert the CD the installation program will be started automati...

Page 7: ...re PC Bedienung VEGABAR 12 2 Interface converter 3 Connection cable 4 VEGABAR 12 5 Processing system PLC Voltage supply 5 2 Start PC operation Start the PC operation of VEGABAR 12 via the Windows star...

Page 8: ...First of all select Read Data and Adjustment Sensor data will be loaded the window Sensor Data appears 8 PC operation VEGABAR 12 5 Operation 35584 EN 090702...

Page 9: ...t Enter Adjustment The menu window Adjustment will be opened Enter the pressure values for Min Adjustment 4 mA and Max Adjustment 20 mA in bar Con rm the setting with Store to device The data will be...

Page 10: ...lable in certain cases for fault recti cation or integration of new functions For further information see our homepage www vega com 6 2 Remove interferences Depending on the fault PC operation may gen...

Page 11: ...ia Start Settings Control Panel 2 Select VEGABAR 12 from the list and push the button Modify Remove 3 Carry out the deinstallation in the way suggested by the assistant and complete the procedure with...

Page 12: ...ntel Pentium AMD min 500 MHz Memory min 128 MB RAM Hard disk min 200 MB free memory Mouse Microsoft compatible Resolution of the graphic min 1024 x 768 Interface RS232 Software Operating system Window...

Page 13: ...software are normally provided via update upgrade d VEGA will decide within the framework of the guarantee where errors will be diagnosed and corrected at VEGA headquarters or at the customer s site Y...

Page 14: ...licence agreement permanently provided you transfer the complete software product incl all components of the media and the printed material and that the recipient agrees to the conditions of this lice...

Page 15: ...PC operation VEGABAR 12 15 8 Supplement 35584 EN 090702...

Page 16: ...vega com Printing date ISO 9001 All statements concerning scope of delivery application practical use and operating conditions of the sensors and processing systems correspond to the information avail...

Reviews: